Blood Pressure Analysis

AcqKnowledge Stellar BP Data

AcqKnowledge extracts various cycle-by-cycle measures from arterial blood pressure (ABP) and ECG signals. Use an NIBP100D Noninvasive Blood Pressure system, or other, continuous blood pressure amplifier to record blood pressure, or use a catheter to record direct arterial blood pressure. The software can measure Systolic BP (SBP or PSys), Diastolic BP (DBP or PDias), Mean BP (MAP or Pmean), Heart Rate (BPM), Peak to Peak Blood Pressure (PPBP), and dP/dt max and min on a cycle-by-cycle basis for real-time display of the data.

The software also includes a fully automated analysis routine that scores the waveform and exports all of the results to a text file or to a spreadsheet.

See More...

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

The software also includes a fully automated analysis routine that scores the waveform and exports all of the results to a text file or to a spreadsheet.

  • If the ECG and blood pressure signals have not been classified when this analysis is performed, events for diastolic, systolic, and ECG boundaries will be inserted as necessary.
  • If systolic, diastolic, and Q events are already present on the signals, however, they will be used.

On a cycle-by-cycle basis, the arterial blood pressure analysis transformation extracts the following measures:

NameAbbrev.
Diastolic
Ejection timeET
Heart rateHR
Maximum dP/dtdP/dt max
Mean blood pressureMBP
Minimum dP/dtdP/dt min
QA IntervalQA
Recovery Interval%REC
Systolic
Time to peak pressureTTPK

When textual output is used, the average of all of these measures will be output as the last row of the table.

BP spreadsheet

Videos

Support

Application Notes

Knowledge Base

Spotlight On
Cardiac Output amplifier

NICO Smart Amplifier

The NICO Smart Amplifier is specifically designed to measure thoracic impedance for performing noninvasive cardiac output measurements. The amplifier terminates in two connectors for impedance (Z) and its derivative (dZ), and has a 3 m cable that connects directly to an AMI100D Amplifier Input Module. Use with EL526 strip electrodes and CBL246 adapter or with EL500 […]

View All
Latest News

New Citations | BIOPAC in ANS Research

The autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration