Blood Pressure Analysis

AcqKnowledge Stellar BP Data

AcqKnowledge extracts various cycle-by-cycle measures from arterial blood pressure (ABP) and ECG signals. Use an NIBP100D Noninvasive Blood Pressure system, or other, continuous blood pressure amplifier to record blood pressure, or use a catheter to record direct arterial blood pressure. The software can measure Systolic BP (SBP or PSys), Diastolic BP (DBP or PDias), Mean BP (MAP or Pmean), Heart Rate (BPM), Peak to Peak Blood Pressure (PPBP), and dP/dt max and min on a cycle-by-cycle basis for real-time display of the data.

The software also includes a fully automated analysis routine that scores the waveform and exports all of the results to a text file or to a spreadsheet.

See More...

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

The software also includes a fully automated analysis routine that scores the waveform and exports all of the results to a text file or to a spreadsheet.

  • If the ECG and blood pressure signals have not been classified when this analysis is performed, events for diastolic, systolic, and ECG boundaries will be inserted as necessary.
  • If systolic, diastolic, and Q events are already present on the signals, however, they will be used.

On a cycle-by-cycle basis, the arterial blood pressure analysis transformation extracts the following measures:

NameAbbrev.
Diastolic
Ejection timeET
Heart rateHR
Maximum dP/dtdP/dt max
Mean blood pressureMBP
Minimum dP/dtdP/dt min
QA IntervalQA
Recovery Interval%REC
Systolic
Time to peak pressureTTPK

When textual output is used, the average of all of these measures will be output as the last row of the table.

BP spreadsheet

Videos

Support

Application Notes

Knowledge Base

Spotlight On
free BIOPAC webinar

Save the Physiology Practical Lab with BSL HOME

BIOPAC is introducing Biopac Student Lab Home (BSL HOME)—a new product specifically geared towards teaching physiology labs remotely so students can still get hands-on, practical lab experience if social distancing and stay-at-home orders keep them out of the lab..

BSL HOME will allow your students to conduct physiology labs in the safety of their own home, dorm room, or any remote location.

Watch Now!

Register Now
Latest News

BIOPAC Systems Helps STARK Industries Launch VITAL Ventilator for NASA JPL

BIOPAC’s ventilator testing equipment and expertise supports STARK Industries’ effort to manufacture, validate, and test NASA JPL’s VITAL Ventilators Goleta, California – June 16, 2020 BIOPAC Systems, Inc. announced a partnership with STARK Industries, LLC to provide ventilator validation and testing equipment for the mass production of ventilators. STARK Industries was awarded a global license […]

New Citations | Kick Off Summer with New Research in Exercise Physiology!

Comparing Muscle Movement and Involvement between Boxing Punches In the fast-paced, high-intensity combat sport of boxing, the right punch can win a fight. However, boxing is also a sport where opponents can become exhausted in mere minutes of action, and prioritizing their strength is key to winning a fight. This team recorded EMG on test […]

Read All
Request a Demonstration
Request a Demonstration