BIOPAC® Systems, Inc. Logo

Stim-Response | Virtual Reality

Immerse Your Subjects in a BIOPAC 3D VR world

Design experimental conditions impossible in the real world

Record physiological data as the virtual environment influences subjects

virtual reality with BIOPAC

Obtain Stimulus-response data across multiple disciplines

Now researchers can obtain and analyze various types of stimulus-response data across multiple disciplines and run automated routines to extract measurements in tabular format for further statistical analysis with powerful AcqKnowledge software  from BIOPAC.

Automated analysis routines include

Explore new worlds of discovery with VR

BIOPAC provides a full range of virtual reality platforms that give researchers controlled and replicable experimental setups and allow manipulation that would be impossible or prohibitively expensive in the real world. A wide variety of virtual worlds are available. Events from the virtual or augmented world (AR) and physiological data are synchronized. The linking protocol allows you to use a feedback loop for greater control and automation of the VR world—change the VR world in real time, based on the subject’s responses.

See More...

Turnkey solutions

Complete hardware/software solutions. Pre-made scenarios

Intuitive, Elegant AcqKnowledge Software

Powerful automated analysis. Instantly & easily view, measure, analyze, and transform data.

Comprehensive physiological monitoring and analysis

Monitor and record ECG, EEG, EOG, EMG, EGG, EDA, temperature, respiration, pulse, others.

Application Starter Hardware  

Hardware Packages   |   Stim-Response | Virtual Reality

Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.

Wired

Details

Stimulus-Response

The Stim-Response analysis package in AcqKnowledge aids in the analysis of various types of stimulus-response studies across multiple disciplines including psychophysiology, exercise science, communications, human factors, and more. Measurements are taken from the responses to each stimulus type and are extracted in tabular format for further statistical analysis. The stim-response package consists of two routines.

Digital Input to Stim Events—Identify and label stimulus events corresponding to any combination of digital inputs. The Digital input to stim events function works with TTL trigger information coming from applications including E-Prime®, SuperLab®, DirectRT®, MediaLab®, Inquisit®, Vizard, and Presentation. Convert TTL data acquired on the digital channels of an MP device into specific stimulus events. For each stimulus, a light bulb icon is placed in the global events bar, the event is labeled with the stimulus event type, and a mouse-over tag includes the event time. All event information is accessible and exportable from the Event Palette. The digital input to stim events program is useful when you have many different types of stimulus event groups.

Stim-Response Analysis—Extract measurements with fixed intervals.

Virtual Reality

Virtual, Reality, VR, Catalog, Demo The BIOPAC virtual reality platform provides controlled and replicable experimental setups and allows manipulation of the environment (and avatars) that would be impossible or prohibitively expensive in the real world. Synchronization of events from the virtual world with physiological data from an MP System allows accurate and automated data analysis. The linking protocol allows you to use a feedback loop for greater control and automation of the VR world; change the VR world in real time, based on the subject’s responses.

The virtual reality platform includes VR protocol, VR Toolkit (WorldViz Vizard VR Toolkit/Developer edition interface software), VR demos/tutorials, VR environment resources, and VR hardware options, including actuators, scent delivery, and HMD.

Integrate Multi-subject monitoring and/or Eye Tracking: systems,

  • AcqKnowledge media functionality synchronizes the video to any physiological data being recorded with the MP150 Research System. Simply scroll through either the physiological data or video and watch the corresponding linked data move to the same location.

Applications for VR protocols are varied and include Psychology (phobias, PTSD, etc.), Ergonomics, Neuromarketing & Neuroeconomics (Consumer Research), Biomechanics & Kinesiology, Computer Modeling/Simulation, Education, and Training: hazard, medical, etc.

Advanced Features Spotlight

Software controlled stimulator

Stimulator - Software Controls in AcqKnowledge

Use the graphical setup features in the AcqKnowledge Stimulator dialog to design the appropriate stimulus. The stimulator software allows you to control external stimulators for More...

AcqKnowledge digital stim to events feature

Stimulus Presentation Event Marking

AcqKnowledge® includes a fully automated event driven data reduction program for Event Related Potential and other stimulus-response (S-R) applications. The feature comprises of two tools: More...

Video Monitoring System 4 Cameras

Camera Systems - Multi-Subject Monitoring

New Multi-Subject Video Monitoring Systems BIOPAC now offers multi-subject video monitoring systems. The new Camera Systems record multiple subjects or camera angles and AcqKnowledge media More...

eye_hmd1_bin2.jpg

Eye Tracking

BIOPAC offers an array of eye tracking systems that are easily integrated with a VR system. monocular and binocular systems fixed head or moveable systems More...

Preferred Physiology VR Workstation

Virtual Reality with fNIR

fNIR functional near infrared systems for optical brain imaging can interface with the BIOPAC virtual reality platform. BIOPAC VR provides controlled and replicable experimental setups More...

Videos

VR Demo – Acrophobia

Support

Spotlight On
MR Safe airflow interface

Airflow Subject Interface for MRI

The AFT35-MRI is a low profile mouthpiece and non-rebreathing T-valve assembly specifically designed to fit inside an fMRI head coil.* Use the AFT35-MRI to perform the following airflow and lung volume tests: End Tidal CO2 VO2 max Breath-by-breath Air Flow Breath-by-breath Volume Metabolic Studies The assembly includes a Luer lock port for easy interface to […]

View All
Latest News

BIOPAC Ranked #1 for Physiology Experiments by HAPS Members

The Human Anatomy & Physiology Society (HAPS) found that BIOPAC’s Student Lab System (BSL) and AcqKnowledge software were the number one ranked data acquisition and analysis systems for physiology experiments performed in introductory A&P labs. According to HAPS surveys conducted in 2013 and 2016, BIOPAC products are used and preferred by members in more labs than […]

Integrating Eye Tracking Data with Neuromarketing Parameters

Hardware and software packages from BIOPAC allow commercial consumer marketing teams to easily combine precise eye tracking data with physiological data recording. Here are a few notable studies recording physiology with eye tracking data: Predicting Advertising Success: While neurophysiological methods have become increasingly popular to better understand marketing phenomena among academics and practitioners, the success of […]

Read All
Request a Demonstration
Request a Demonstration