294 – Trans-radial Electrical Bioimpedance Velocimetry (TREV and TRUEV)
Home>Application Notes>294 – Trans-radial Electrical Bioimpedance Velocimetry (TREV and TRUEV)
Blood Flow Measurements using the NICO100D
This application note discusses Trans-Radial-Ulnar Electrical bioimpedance Velocimetry (TRUEV); measurements and analysis; the configuration discussed interrogates both the radial and ulnar (TREV >> TRUEV) arteries.
Abstract We describe methods and software resources for a bioimpedance measurement technique, “trans-radial electrical bioimpedance velocimetry” (TREV) that allows for the non-invasive monitoring of relative cardiac contractility and stroke volume. After reviewing the relationship between the measurement and cardiac contractility, we describe the general recording methodology, which requires impedance measurements of the forearm. We provide open-source Jupyter-based software (operable on most computers) for deriving cardiac contractility from the impedance measurements. The software includes tools for removing variance associated with heart rate and respiration. We demonstrate the ability of this bioimpedance measurement for tracking beat-to-beat changes of contractility in a maximal grip force production task. Critically, the results demonstrate both a reactive increase in contractility with force production, and suggest there is a learned increase in contractility prior to grip onset, consistent with anticipatory allostatic autonomic regulation mediated by sympathetic inotropy. The method and software should be of broad utility for investigations of event-related cardiac dynamics in psychophysical studies.
ICG: Impedance Cardiography/Cardiac Output - Record cardiac output, thoracic impedance changes, or any kind of bioimpedance signal. Use AcqKnowledge for a fully automated ICG analysis and dZ/dt waveform classifier.
Cardiovascular Hemodynamics - Hardware for human and animals. Measure continuous BP, ECG, stroke volume, cardiac output, PPG, etc. For animal and tissue look at acute and chronic dose-response.
ECG: Cardiology - Connect up to 16 ECG input leads with MP160 system. Use automated analysis features for HRV, RSA, to classify heartbeats, identify arrhythmias, and perform ECG averaging.
Plethysmography - Record PPG, measure BP indirectly, look at appendage size variations, and perform sexual arousal studies using BIOPAC or 3rd-party transducers.
MedelOpt® Infinity systems provide high-density NIRS with EEG for very high density whole brain mapping and custom advanced montages with variable depths. The flexible, adaptable headset allows acquisition for up to 8 hours. MedelOpt adjusts to real-world situations or Virtual Reality environments with a specific design to fit any head mounted VR display. Use for research […]
The autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]
BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]