To perform on-line AER studies, combine the auditory output options of the STM100C Stimulator with the signal averaging functions of the MP System.
Present auditory stimuli directly via a tubephone and the software will display results and allow users to measure the amplitude and time of both Short Latency Auditory Evoked Potential (SAEP) and Middle Latency Auditory Evoked Potential (MAEP) and all Fast (2-12 msec), Middle (12-50 msec), Slow (50-300 msec), and Late responses (250-600 msec).
Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.
MP36R System
Wired | Auditory Evoked Response (AER) & Jewett Sequence
MP36R with AcqKnowledge plus SuperLab system, monaural headphones, electrode lead adapter, 8 mm shielded TP electrode and 8 mm unshielded TP electrode
MP36R System
Wired | Auditory Evoked Response (AER) & Jewett Sequence
MP36R with AcqKnowledge plus lead set, 8 mm snap electrodes & gel, and tubephone
MP160 System
Wired | Auditory Evoked Response (AER) & Jewett Sequence
MP160 System with evoked response amplifier, reusable electrodes, stimulator & headphones
MP160 System
Wired | Auditory Evoked Response (AER) & Jewett Sequence
MP160 System with evoked response amplifier, reusable electrodes, stimulator & tubephone
MP160 System
Wired | Auditory Evoked Response (AER) & Jewett Sequence
MP160 with AcqKnowledge plus ERS amp, electrode cap & SuperLab system with Optical Interface
MP36R System
MP36R System
MP160 System
MP160 System
MP160 System
MP160 System
MRI | Auditory Evoked Response (AER) & Jewett Sequence
MP160 with AcqKnowledge plus EEG amp for MRI & E-Prime Professional Stimulation System
MP160 System
MP36R System
Animal | Auditory Evoked Response (AER) & Jewett Sequence
MP36R with AcqKnowledge plus SuperLab system, monaural headphones, electrode lead adapter, 8 mm shielded TP electrode and 8 mm unshielded TP electrode
MP36R System
Animal | Auditory Evoked Response (AER) & Jewett Sequence
MP36R with AcqKnowledge plus electrode lead adapter and three 12 mm TP unipolar needle electrodes
MP160 System
Animal | Auditory Evoked Response (AER) & Jewett Sequence
MP160 System with evoked response amplifier, needle electrodes, and stimulator
MP36R System
MP36R System
MP160 System
High-performance mobile fNIR Imaging Systems are stand-alone functional brain imaging solutions for continuous NIR spectroscopy (NIRS). These top of the line systems provide cognitive function assessment and eliminate a great many of the drawbacks of a functional MRI. Mobile subjects are comfortable and can respond naturally in real-world situations to take a test or perform mobile […]
View AllBIOPAC provides software and hardware that allows research teams to run autonomic function tests while collecting physiological data. Here are a few studies focusing on BIOPAC’s ability to record physiological signals during autonomic function testing. The Internet, Sleep, and Heart Rate Does internet usage lead to poorer sleep? Using a BIOPAC Data Acquisition System to measure cardiovascular […]
BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]
Read All