Apply signal averaging on the ECG signal to detect VLPs, the small-amplitude, short-duration waves that occur after the QRS complex and are precursors to cardiac arrhythmias. Perform off-line averaging to trigger on the R-wave peaks and average the time delta after each peak, then use the measurement tools to calculate the duration and RMS values of the VLPs. If the ECG complex analysis is run before performing the ensemble average, the software will indicate how many events were identified within the selected area of data.
BIOPAC Research Solutions | ECG
Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.
MP36R System
Wired | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus lead set & long-term recording electrodes
MP36R System
Wired | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus electrode lead adapter, adhesive disks, 8 mm shielded & unshielded TP electrodes
MP160 System
Wired | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, multi-lead cable,long-term electrodes, and impedance checker
MP160 System
Wired | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, module extension cable and long-term electrodes
MP36R System
MP36R System
MP160 System
MP160 System
Mobita
Wireless | Ventricular Late Potentials (VLPs)
Mobita system for up to 32-CH Wireless Biopotentials plus AcqKnowledge
MP160 System
Wireless | Ventricular Late Potentials (VLPs)
MP160 System with AcqKnowledge plus BioNomadix wireless ECG amp and disposable long-term recording electrodes
BioNomadix Logger
Wireless | Ventricular Late Potentials (VLPs)
BioNomadix Logger and one transmitter for wireless ECG, 30 cm leads & disposable long-term electrodes, plus Impedance Checker
Mobita
MP160 System
BioNomadix Logger
MP160 System
MRI | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG MRI amp, MRI cable/filter system to biopotential amps, disposable radiotranslucent electrodes and electrode gel
MP160 System
MP36R System
Animal | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus electrode lead adapter and three 12 mm TP unipolar needle electrodes
MP36R System
Animal | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus needle electrodes
MP160 System
Animal | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, module extension cable, and unipolar needle electrodes
MP36R System
MP36R System
MP160 System
Learn how to record event-related or endogenous evoked potentials (ERP).
You will learn about:
– Introduction to ERPs
– Theory and guidelines for recording ERPs
– How to record great ERPs data
– Wired and wireless wearable EEG-fNIRS bimodal response to oddball paradigm
– How to mismatch negativity in a virtual world
– How to prepare data for analysis
– Workflow Automation Tools
On Demand Playback
Register NowThe mind and body work together in many ways and psychophysiology research provides insight to these connections. BIOPAC has a variety of systems to power your emotion, arousal, stress, cognitive assessment, group interaction, startle, and other psychophysiology research. Here are some recent studies that have used BIOPAC systems for psychophysiological research… Skin conductance, facial EMG, […]
For immediate release: January 4, 2023 Amiens, France and GOLETA, California, USA Seenel Imaging SAS and BIOPAC Systems, Inc. have formed a long-term global partnership to distribute MedelOpt®, Seenel Imaging’s groundbreaking wearable neuroimaging device for the neuroscience research market. Seenel Imaging, based in France, continues its international expansion by partnering with BIOPAC Systems, […]
Read All