Apply signal averaging on the ECG signal to detect VLPs, the small-amplitude, short-duration waves that occur after the QRS complex and are precursors to cardiac arrhythmias. Perform off-line averaging to trigger on the R-wave peaks and average the time delta after each peak, then use the measurement tools to calculate the duration and RMS values of the VLPs. If the ECG complex analysis is run before performing the ensemble average, the software will indicate how many events were identified within the selected area of data.
BIOPAC Research Solutions | ECG
Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.
MP36R System
Wired | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus lead set & long-term recording electrodes
MP36R System
Wired | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus electrode lead adapter, adhesive disks, 8 mm shielded & unshielded TP electrodes
MP160 System
Wired | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, multi-lead cable,long-term electrodes, and impedance checker
MP160 System
Wired | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, module extension cable and long-term electrodes
MP36R System
MP36R System
MP160 System
MP160 System
MP160 System
Wireless | Ventricular Late Potentials (VLPs)
MP160 System with AcqKnowledge plus BioNomadix wireless ECG amp and disposable long-term recording electrodes
BioNomadix Logger
Wireless | Ventricular Late Potentials (VLPs)
BioNomadix Logger and one transmitter for wireless ECG, 30 cm leads & disposable long-term electrodes, plus Impedance Checker
MP160 System
BioNomadix Logger
MP160 System
MRI | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG MRI amp, MRI cable/filter system to biopotential amps, disposable radiotranslucent electrodes and electrode gel
MP160 System
MP36R System
Animal | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus electrode lead adapter and three 12 mm TP unipolar needle electrodes
MP36R System
Animal | Ventricular Late Potentials (VLPs)
MP36R with AcqKnowledge plus needle electrodes
MP160 System
Animal | Ventricular Late Potentials (VLPs)
MP160 plus AcqKnowledge with ECG amp, module extension cable, and unipolar needle electrodes
MP36R System
MP36R System
MP160 System
Learn a technique—Trans-radial Electrical Bioimpedance Velocimetry (TREV)—that is more user-friendly and less invasive than the transthoracic method. TREV measures blood movement in the radial and ulnar arteries of the forearm via bioimpedance.
Topics Covered:
– Presentation and discussion of TREV
– Derived Indices Relevant to TREV
– Hardware setup
– Participant setup
– Recognizing good quality and bad quality data
– Demonstration with the grip anticipation test
– Review of results from other tests
Watch On Demand
Exercise physiology is the study of the body’s response to physical activity. Research in exercise physiology allows for insights in health and for a better understanding of the functions of the body at work. Here are some recent studies in exercise physiology that utilized BIOPAC tools for their research… Effect of exercise on electrocardiographic parameters […]
BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]
Read All