MRI ECG Recording

Record ECG, heart rate, and R-R interval from a subject inside a functional MRI with a BIOPAC MP150 data acquisition system. The AcqKnowledge software (included with the MP150) will identify the frequency of the MRI gradient noise and eliminate it from the physiological data. This can be done in real-time or during post processing. The quality of the ECG signal is suitable for recording heart rate and R-R interval when the MRI is scanning.

The MP150 system and the ECG100C Electrocardiogram amplifier are placed in the control room. An MECMRI-BIOP filtered cable set is connected to the amplifier and the electrode leads. The cable set consists of three components:

The MECMRI-2 connects to the amplifier and the filter, which is mounted on the patch panel. The MECMRI1 connects to the other side of the filter and interfaces with LEAD108B or LEAD108C RT electrode leads.

See More...

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

The following data was taken from a subject while they underwent an fMRI. The top raw ECG channel (burgundy) shows the ECG with the gradient noise. The second channel shows the filtered ECG signal (red) and then finally the HR channel (blue).

ECG with gradient noise removed

Click here to request Application Note 242 – ECG & FMRI (pdf).

Recommended Reading

Thoralf Niendorf, Lukas Winter and Tobias Frauenrath (2012). Electrocardiogram in an MRI Environment: Clinical Needs, Practical Considerations, Safety Implications, Technical Solutions and Future Directions , Advances in Electrocardiograms – Methods and Analysis, PhD. Richard Millis (Ed.), ISBN: 978-953-307-923-3, InTech, DOI: 10.5772/24340.

Support

Application Notes

Knowledge Base

Hardware Packages   |   MRI ECG Recording

Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.

MRI

Spotlight On

Noninvasive Blood Pressure System for MRI

The NIBP-A-MRI CareTaker4 system measures relative central arterial pressure to provide continuous, noninvasive “Beat-by-Beat” Blood Pressure from at rest humans (≥ 15 kg) in the MRI; measures include Diastolic, Systolic, Mean Arterial Pressure.; heart rate (HR) data is available. The system uses the scientific method of Pulse Decomposition Analysis (“PDA”). Key features Continuous, noninvasive monitoring […]

View All
Latest News

Electrocardiography Guide Now Available

BIOPAC’s just released Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines […]

New Citations | Twinkle, Twinkle, Little Star, Muscles & Computer Mice

Recent Studies using BIOPACs MP-Series (MP160, MP150) data recorders, ECG Amplifiers, and BioNomadix Wireless recorders: Singing style to infants Mothers around the world sing to infants, presumably to regulate their mood and arousal. Lullabies and playsongs differ stylistically and have distinctive goals. Mothers sing lullabies to soothe and calm infants, and playsongs to engage and […]

Read All
Request a Demonstration
Request a Demonstration