MRI ECG Recording

Record ECG, heart rate, and R-R interval from a subject inside a functional MRI with a BIOPAC MP150 data acquisition system. The AcqKnowledge software (included with the MP150) will identify the frequency of the MRI gradient noise and eliminate it from the physiological data. This can be done in real-time or during post processing. The quality of the ECG signal is suitable for recording heart rate and R-R interval when the MRI is scanning.

The MP150 system and the ECG100C Electrocardiogram amplifier are placed in the control room. An MECMRI-BIOP filtered cable set is connected to the amplifier and the electrode leads. The cable set consists of three components:

The MECMRI-2 connects to the amplifier and the filter, which is mounted on the patch panel. The MECMRI1 connects to the other side of the filter and interfaces with LEAD108B or LEAD108C RT electrode leads.

See More...

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

The following data was taken from a subject while they underwent an fMRI. The top raw ECG channel (burgundy) shows the ECG with the gradient noise. The second channel shows the filtered ECG signal (red) and then finally the HR channel (blue).

ECG with gradient noise removed

Click here to request Application Note 242 – ECG & FMRI (pdf).

Recommended Reading

Thoralf Niendorf, Lukas Winter and Tobias Frauenrath (2012). Electrocardiogram in an MRI Environment: Clinical Needs, Practical Considerations, Safety Implications, Technical Solutions and Future Directions , Advances in Electrocardiograms – Methods and Analysis, PhD. Richard Millis (Ed.), ISBN: 978-953-307-923-3, InTech, DOI: 10.5772/24340.

Support

Application Notes

Knowledge Base

Hardware Packages   |   MRI ECG Recording

Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.

MRI

Spotlight On
Smart Center controller, 2-3 wireless transmitters & AcqKnowledge plus case

Smart Center | Stand-alone BioNomadix Wireless Systems

Smart Center Stand-alone, Portable Wireless Physiology Systems Smart Center Essentials entry-level system includes a Smart Center Device (BN-SMART with USB power cable), 2 or 3 Transmitters (BN-xxx-T with chargers); AcqKnowledge for Smart Center, and a case. Smart Center Enhanced adds a Logger (BN-LOGGER) and Basic Scripting License (ACK100W-BAS) to the Smart Center Device (BN-SMART with powercable), 3 […]

View All
Latest News

New Citations | Neuroscience Studies with BIOPAC

Effects of MDMA on attention to positive social cues for behavioral disorders The psychostimulant drug 3,4-methylenedioxymethamphetamine (MDMA) reportedly produces distinctive feelings of empathy, closeness with others and increased social behavior. Researchers are exploring the potential of this chemical for treatment of psychiatric disorders, such as autism spectrum disorder (ASD) and post-traumatic stress disorder (PTSD). This […]

Electrocardiography Guide Now Available

BIOPAC’s just released Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines […]

Read All
Request a Demonstration
Request a Demonstration