MRI ECG Recording

Record ECG, heart rate, and R-R interval from a subject inside a functional MRI with a BIOPAC MP150 data acquisition system. The AcqKnowledge software (included with the MP150) will identify the frequency of the MRI gradient noise and eliminate it from the physiological data. This can be done in real-time or during post processing. The quality of the ECG signal is suitable for recording heart rate and R-R interval when the MRI is scanning.

The MP150 system and the ECG100C Electrocardiogram amplifier are placed in the control room. An MECMRI-BIOP filtered cable set is connected to the amplifier and the electrode leads. The cable set consists of three components:

The MECMRI-2 connects to the amplifier and the filter, which is mounted on the patch panel. The MECMRI1 connects to the other side of the filter and interfaces with LEAD108B or LEAD108C RT electrode leads.

See More...

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

The following data was taken from a subject while they underwent an fMRI. The top raw ECG channel (burgundy) shows the ECG with the gradient noise. The second channel shows the filtered ECG signal (red) and then finally the HR channel (blue).

ECG with gradient noise removed

Click here to request Application Note 242 – ECG & FMRI (pdf).

Recommended Reading

Thoralf Niendorf, Lukas Winter and Tobias Frauenrath (2012). Electrocardiogram in an MRI Environment: Clinical Needs, Practical Considerations, Safety Implications, Technical Solutions and Future Directions , Advances in Electrocardiograms – Methods and Analysis, PhD. Richard Millis (Ed.), ISBN: 978-953-307-923-3, InTech, DOI: 10.5772/24340.

Support

Application Notes

Knowledge Base

Hardware Packages   |   MRI ECG Recording

Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.

MRI

Spotlight On
NIBP100E Amplifier ships with 3 finger cuffs

Noninvasive Blood Pressure Amplifier

The NIBP100E noninvasive blood pressure system provides continuous, beat‐to‐beat, blood pressure signal and values (Sys, Dia, MAP) and Pulse Rate (PR)*.  The system outputs a continuous blood pressure waveform that is similar to a direct arterial pressure waveform. The amplifier provides values for systolic, diastolic, mean blood pressure, and heart rate. The NIBP100E amplifier with CNAP™ […]

View All
Latest News

New Citations | Food for Thought

With a new year approaching, many people around the world will gather with friends and family to celebrate. What is one commonality across cultures to celebrate? Food! BIOPAC provides software and hardware that allows research teams to study physiological measures to see how people interact with food. Here are a few notable studies using BIOPAC […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration