– Top 10 Knowledge Base Queries [Knowledge Base]

These are the ten most common Knowledge Base queries: AcqKnowledge iLok USB Key installation Unable to establish communication with any data acquisition hardware Compatibility | OS computer requirements BSL Analysis…

* CLEANING GUIDELINES * [Knowledge Base]

External Cleaning / Disinfecting Instructions For any BIOPAC Systems data acquisition, amplifier, or accessory module: To clean the surface of the module: wipe lightly with a dry, lint-free cloth, or…

About License Keys [Knowledge Base]

AcqKnowledge software is distributed on a “USB key” and may include additional key(s) based on the MP Research System purchased, “Licensed Feature” add-ons, or site licenses included, if any. Key…

AC mode [Knowledge Base]

AC mode indicates that a high-pass (HP) filter has been applied to the signal that you are recording. An HP filter removes the low-frequency components of a signal. The most common…

AcqKnowledge 4 and Windows XP [Knowledge Base]

AcqKnowledge 4.x is officially released for Windows 7 and Vista OS. AcqKnowledge has not been rigorously tested on Windows XP. If you choose to install and run AcqKnowledge 4 under Windows XP,…

AcqKnowledge accuracy [Knowledge Base]

AcqKnowledge performs all internal calculations to the accuracy defined by the IEEE format for double-precision floating point numbers and stores the results of those calculations in double-precision floating point format.…

AcqKnowledge backwards compatibility [Knowledge Base]

AcqKnowledge files are backwards compatible. Files saved with earlier versions of the software will open in newer versions of the software.

AcqKnowledge iLok key lost or unavailable [Knowledge Base]

What can I do if I’ve lost my iLok key or left it at home? If you received and lost an iLok key for AcqKnowledge 4, submit a Support Ticket with…

AcqKnowledge iLok USB Key Issues [Knowledge Base]

In some instances, iLok drivers will not install properly or will fail to install, leading to connection failure between AcqKnowledge and the iLok USB Key. If the iLok USB drivers did…

AcqKnowledge: Newest Features [Knowledge Base]

New Features and Enhancements Increase the Power & Flexibility of AcqKnowledge! AcqKnowledge software is included with each MP160 and MP36R System and some integrated systems; it can also be purchased separately. Check BIOPAC…

AFT11 Series coupler guide [Knowledge Base]

Pick the AFT11 Series Coupler that matches the port sizes you want to interface. tem 1 Dimensions Item 2 Dimensions BIOPAC Coupler 15 mm OD 22 mm ID AFT11B 20…

Amplifier analog output signals [Knowledge Base]

The UIM100C is bidirectional. With a BIOPAC amplifier connected to the UIM100C, the appropriate input becomes an output. For example, if you have an ECG100C module set to channel 1,…

Amplifier baseline offset adjustment [Knowledge Base]

If the signal from the amplifier is not on zero, it is possible to remove the offset by using the Zero Adj screw at the top of the amplifier. Make…

Amplifier conversion – 2 mm to touchproof [Knowledge Base]

Use the CBL201 to convert older amplifiers that use 2 mm pin sockets to the newer 1.5 mm touchproof connectors. This is useful if you have an older amplifier with…

Amplifier filter settings [Knowledge Base]

All BIOPAC amplifiers have multiple low pass and high pass filter settings. When setting the switches on the amplifier, the following rules apply: The lowest Low Pass filter value will be applied…

Amplifier module filter response times [Knowledge Base]

The MP series amplifier modules incorporate a variety of filtering options. The low pass filtering options have an effect on the signal response time, which is sometimes referred to as…

Arbitrary waveform stimulation [Knowledge Base]

AcqKnowledge can play the digital representation of a signal in analog form through the two Analog Output ports (bottom left front face of the UIM100C or HLT100C).  The most flexible…

Artifact Rejection verification procedure [Knowledge Base]

When data acquisition is configured to acquire using “Averaging”, some signal amplitude excursions may need to be excluded during the averaging process. Artifact Rejection, available via a checkbox in the averaging setup, is…

Audio recording synchronization [Knowledge Base]

When performing some experiments, it may be desirable to link a recorded audio file to a recorded data file.  For instance, a subject may be speaking, listening to voice commands,…

B-Alert “Use B-Alert Definition File” generates error [Knowledge Base]

B-Alert in AcqKnowledge 4.4.1 and earlier: Attempting to record data after disabling the “Use B-Alert Definition File” option generates an “acquisition cannot continue” error message. Note that this issue is common…

B-Alert Gauges Unresponsive [Knowledge Base]

B-Alert in AcqKnowledge 4.4.1 and earlier: Brain State Gauge Surface and Heat Maps are unresponsive during acquisition; colors remain a uniform green (Surface Map) and yellow (Heat Map). This is most…

Band-pass and band-stop filters [Knowledge Base]

A band pass filter allows the energy concentrated between two given frequencies (X and Y) to pass while it attenuates the signal's energy at other frequencies. It is equivalent to…

BioHarness data logging with Windows 8 [Knowledge Base]

When using the BioHarness data logging feature and importing the data logging file to AcqKnowledge 4.3 under Windows 8 OS, the user must be in 'administrator' mode.

BioHarness pairing with BT [Knowledge Base]

The BioHarness system does not require a pairing code if you are using AcqKnowledge software to interface with your existing BT technology. AcqKnowledge performs pairing automatically after launching, assuming that BioHarness…

Bioimpedance Methods [Knowledge Base]

Related Hardware Compatible with MP160 Smart Amplifiers NICO100D Cardiac Output, EBI100D Electrical Bioimpedance Amplifiers NICO100C Cardiac Output, EBI100C Electrical Bioimpedance MRI NICO100C-MRI Cardiac Output Amplifier Wireless BN-NICO Cardiac Output Amplifier & BN-NICO-T Transmitter Compatible with MP36 and MP36R (4-channel…

BioNomadix Signal Interruption [Knowledge Base]

If a BioNomadix wireless physiology signal displays dropout/flatline… On a single channel Make sure transducer/lead is firmly inserted to transmitter channel, electrodes are fully adhered, and leads are not pulling…

BioNomadix Transmitter Battery Level [Knowledge Base]

BioNomadix Transmitter battery life is indicated on the transmitter via the color sequence of LED flashes (blinks) by Status. LED Color Pattern  |  Charge % green green green green  |  75%…

BIOPAC Basic Scripting – available scripts [Knowledge Base]

BIOPAC Basic Scripting Customize – Acquisition setup and analysis Automate – Acquisitions and perform batched analysis Simplify – Add dialogs and prompts to assist users Expedite – Reduce analysis time…

Biopac Science Lab Line In Ports [Knowledge Base]

The Biopac Science Lab MP40 unit connects to the computer via Line-In. Important—Audio line-in is not the same as headphones. Typical audio line-in connectors are shown below for Windows and…

Biopac Student Lab (BSL) Newest Features [Knowledge Base]

Biopac Student Lab (BSL) integrated hardware, software, and curriculum systems allow students to record data from their own bodies, animal, or tissue preps to learn principles of life science physiology.…

Biopotential amplifier signal validation [Knowledge Base]

It is possible to validate the signals coming from any BIOPAC biopotential amplifier* by using a CBLCALC Calibration Cable. The cable connects to the front of the amplifier and the…

Bipolar EEG [Knowledge Base]

To record bipolar EEG, you will need an EEG amplifier for each pair of electrodes that you want to calculate the potential difference between. It is important to note that…

BSL PRO optimize range [Knowledge Base]

The BSL MP30/35/36 unit has four isolated, human-safe universal biopotential/transducer amplifiers that are controlled by the BSLPRO software. When recording data, it is important to set the gain of the amplifier…

Buffer overflow [Knowledge Base]

Buffer overflow occurs when the system is not fast enough to keep up with the incoming data. MP100 Users: The best way to eliminate this problem is to upgrade to…

Calculating file sizes [Knowledge Base]

File size is limited by the restraints of the operating system and the available memory space on your hard drive or disk (depending to which you save the file). Software…

Calculation Channel Scaling (i.e. Expression Evaluator) [Knowledge Base]

If a calculation channel doesn’t have scaling options, use the Rescale calculation channel and/or Metachannel for scaling. See the AcqKnowledge Software Guide for setup details: Rescale as an independent calculation…

Calibration in Volts, Millivolts, Microvolts [Knowledge Base]

Calibration is performed prior to recording. It is assumed that the amplifier has no offset; see baseline offset if necessary. The gain of an amplifier  indicates the factor of amplification of…

Calibration values [Knowledge Base]

If the Cal 1 and Cal 2 values are very close to zero, check to make sure that: the amplifier is not in AC mode; the filter switches (on the…

Can I get the MSDS for electrode gels? [Knowledge Base]

The Material Safety Data Sheets for various electrode gels may be obtained here: MSDS GEL1 and GEL100 MSDS GEL101A MSDS GEL102 MSDS GEL103 MSDS GEL104 MSDS Electro-Gel

CAP100C electrode connections [Knowledge Base]

The following table shows the pin connnection scheme for the CAP100C. Pin# Placement Color Wire 1 FP1 Brown 2 FP2 Brown 3 F3 Red 4 F4 Red 5 C3 Orange…

Clinical chart grid setting for ECG [Knowledge Base]

Before setting up the grids:   After setting up the grids:     Instructions for AcqKnowledge version 3.9 1. Turn the grid on from “Display > Show > Grid”.2. Right click on…

Combining Video with AcqKnowledge [Knowledge Base]

AcqKnowledge 3.8.2 and above for Windows allows you to synchronize video files with physiological data. This allows you to jump to specific points in either the video or data file,…

Common mistakes/general troubleshooting [Knowledge Base]

Make sure the unit is turned on and connected to the computer. Check for the green circular icon next to the Start button, which indicates that the unit is connected…

Compatibility: OS & Computer Requirements [Knowledge Base]

BIOPAC Software Compatibility Compatibility —check BIOPAC software versions for supported OS and supported hardware Compatibility with macOS and ETHUSB adapter for Research Systems: MP160 is fully compatible, but some steps are required for proper…

Computing heart rate [Knowledge Base]

Heart rate can be derived from various data sources but is not a physically measurable quantity, thus it is “computed” rather than measured. A heart beat may be detected through…

Connecting Calibration Gas Tanks & Mixing Chambers [Knowledge Base]

When using calibration gas tanks with a mixing chamber—such as the AFT15 or the GASSYS2 system—an interface is required between the gas tank barbed ports and the mixing chamber’s Luer…

Connecting the TSD116C Switch Box [Knowledge Base]

The TSD116C has nine wires that have to be connected to the screw terminals on the rear of the UIM100C module.    The black wire must be connected to the 5V…