BIOPAC® Systems, Inc. Logo

Noninvasive Cardiac Output Amplifier for MRI

Selectable signal conditioning—filter or transform data as it is being collected

Cascade up to 16 amplifer modules per MP Research System for multi-parameter or multi-subject studies

Request More Info
View Cart “Disp. RT Dry Electrode, 100/pk” has been added to your cart.
ICG amp for MRI
Part #: NICO100C-MRI

The NICO100C-MRI Impedance Cardiography (ICG) Noninvasive Cardiac Output Module for Magnetic Resonance Imaging records specific parameters associated with cardiac output measurements. The NICO100C-MRI simultaneously measures impedance magnitude (Zo; labeled “Z”) and derivative (dZ/dt; labeled “DZ”) and incorporates special features to help improve measurements during EPI or other scanning sequence in fMRI or MRI. Features include optimized filtering and slew rate limiting for the Zo and dZ/dt signals.

Zo and dZ/dt are recorded at a stimulation frequency of 50 kHz. The module incorporates a precision high frequency current source, which injects a small (4 mA rms) sinusoidal measurement current through the thoracic volume defined by the placement of a set of current source electrodes. A separate set of monitoring electrodes measures the voltage developed across the thorax volume. Because the current is constant, the voltage measured is proportional to the impedance characteristics of the thorax.

The NICO100C-MRI requires the MECMRI-NICO filtered cable set and is used as part of a complete research system, interfacing with the MP160/MP150 data acquisition and analysis platform and AcqKnowledge software, allowing advanced analysis for multiple applications and supporting acquisition of a broad range of signals and measurements. AcqKnowledge includes automated tools for the automatic analysis of impedance cardiography (ICG), cardiac output and other hemodynamic parameters using noninvasive bioimpedance techniques. The software automatically scores the data and provides tabulated results in either a Journal file or Excel.

See More...

MODULAR CONSTRUCTION

Amplifiers snap together for easy system configuration and re-configuration.

Intuitive, Elegant AcqKnowledge Software

Powerful automated analysis. Instantly & easily view, measure, analyze, transform, and report data.

Powerful MP160 Data Acquisition and Analysis System

Flexible, proven modular data acquisition and analysis system for life science research.

NICO for MRI
View Spec PDF

Are You Looking for These?

Part #: NICO100C-MRI
Categories: Amplifiers - Research, MRI Magnetic Resonance Imaging - Research
Subcategories: Bioimpedance - Research, Amplifier Modules - Research

Equivalents
With a different Platform

Details

Compatibility


Featured Citation—ICG during MRI

A study performed BOLD fMRI while simultaneously recording the Electrocardiogram (ECG) and Impedance Cardiogram (ICG) with BIOPAC MRI Smart Amplifiers and accessories. The resolution of the ECG and ICG waveforms was sufficient for measuring stroke volume, cardiac output, pre-ejection period, and left ventricular ejection time during imaging. Results indicate that ICG can be recorded during EPI and, with specific signal processing, can be interpreted similarly as to when recorded outside the MRI. Read more about the technique and results at Psychophysiology:

Cieslak, M., Ryan, W. S., Macy, A., Kelsey, R. M., Cornick, J. E., Verket, M., Blascovich, J. and Grafton, S. (2014), Simultaneous acquisition of functional magnetic resonance images and impedance cardiography. Psychophysiology. doi: 10.1111/psyp.12385

Setup Notes

MRI Use: Conditional to 7T

Condition: NICO100C-MRI Amplifier stays in the Control Room and is used with the MEMRI-NICO filtered cable set and recommended MR leads/electrodes/transducers; tested to 7T.

For operation, the NICO100C-MRI typically connects to the MECMRI-NICO Cable/Filter set. This set incorporates 2 meter cable that connects the NICO100C-MRI from the control room to the patch-panel-attached Pi filter, which pokes through to the chamber room where an 8 meter cable connects between the patch panel filter and the subject electrode leads.

A typical setup uses four “Y” electrode lead adapters (CBL204-MRI) that connect to eight carbon composition unshielded electrode leads terminating in Touchproof sockets (LEAD108B and/or LEAD108C) for connection to disposable carbon composition electrodes (EL508, MR Conditional to 7T; the NICO100C-MRI can also function with other electrode types).

Apply skin preparation gel (ELPREP), then clean/dry skin, then apply electrodes. If electrodes appear dry, and assuming electrodes are not hydrogel type, then more conductive gel (GEL100) can be applied.

IMPORTANT: BIOPAC recommends using the shortest possible electrode leads for recording in the fMRI or MRI.

Videos

ICG dZ dt Classifier

Slew Rate Limiter in AcqKnowledge

MRI - Cleaning Data - EMG example

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

New Citations | Analyze Fake News with Media Psychophysiology

Why do we so easily believe Fake News? 68% of Americans find their news through social media, and the prevalence of incomplete or deceptive news stories dubbed “fake news” has wormed its way into the fabric of modern-day media. In an effort to study how social media based news is perceived, this study measured physiological […]

New Citations | Respiration Analysis and More

Comparing Diaphragm Tissue Between Healthy and Ill Patients The human diaphragm is one of the primary muscles used in respiration, contracting and expanding to control breathing. To measure how much diaphragms move for critically ill patients (in an Intensive Care Unit) compared to diaphragms in a healthy subject, patients at “Papageorgiou” General Hospital in Thessaloniki, […]

Read All
Request a Demonstration
Request a Demonstration