Photoplethysmogram Transducers

Precision Transducer for Research Data Acquisition

Convert biological signals for analysis with MP system or AcqKnowledge®

Request More Info
Photo Plethysmograph Trans TP
Part #: TSD200, TSD200C

The TSD200 photoplethysmogram (PPG) transducer operates with the PPG100C amplifier to record the blood volume pulse waveform via optical (photoplethysmogram) methods.

The TSD200 consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the heme subunit of hemoglobin. When the PPG transducer is placed on the skin, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The PPG waveform peaks when capillary blood volume is maximized.

See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Transducers - Research
Subcategories: General - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


The ergonomic housing design improves contact with the subject and helps reduce motion artifact. The TSD200 is primarily designed for finger attachment, but can be taped to other body locations. The TSD200 comes with a shielded 3-meter cable.

For TSD200C: When the PPG transducer is clipped to the earlobe, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The photodetector operates via incident photons, from an IR transmitter, impacting an IR detector. The incident photons result in a proportional passage of electrons in the detector. The IR detector operates like a photon-controlled current source. The transducer incorporates an appropriate clipping range, with linearity insured for arbitrarily low levels of reflected light. For the expected magnitude of incident infrared light, the photodetector operates in a linear fashion. We have not encountered situations where the detector is operating non-linearly (near saturation).

See also…

Support

Applications

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
SS25LB, TSD121C Hand Dynamometer

Hand Clench Dynamometer for MRI

Use to measure clench force in the MRI; clench force range 0-50 kgf. The lightweight, ergonomically designed transducer provides direct readings in kilograms or pounds. Use in isolation or combine with EMG recordings for in-depth studies of muscular activity. The isometric design improves experiment repeatability and accuracy. The TSD121B-MRI has an 8 meter cable terminated for connection […]

View All
Latest News

New Citations | BIOPAC in Motivation Studies

Discovering and understanding what motivates humans to produce better results has intrigued many researchers. Many researchers have explored the psychophysiological processes that drive our behavior. Here are some recent studies that have used BIOPAC systems to research motivation… Motivation and Pleasure Deficits Undermine the Benefits of Social Affiliation in Psychosis. Blanchard, J. J., Smith, J. […]

New Citations | BIOPAC in Eye Tracking Studies

Eye tracking technology has come a long way and has enabled researchers to conduct mobile experiments and track participants in real world scenarios. These featured studies demonstrate some of the use cases for mobile eye tracking technology. Here are some recent studies that have used BIOPAC systems for eye tracking research… Drivers’ gaze patterns when resuming […]

Read All
Request a Demonstration
Request a Demonstration