Photoplethysmogram Transducers

Precision Transducer for Research Data Acquisition

Convert biological signals for analysis with MP system or AcqKnowledge®

Request More Info
Photo Plethysmograph Trans TP
Part #: TSD200, TSD200C

The TSD200 photoplethysmogram (PPG) transducer operates with the PPG100C amplifier to record the blood volume pulse waveform via optical (photoplethysmogram) methods.

The TSD200 consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the heme subunit of hemoglobin. When the PPG transducer is placed on the skin, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The PPG waveform peaks when capillary blood volume is maximized.

See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Transducers - Research
Subcategories: General - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


The ergonomic housing design improves contact with the subject and helps reduce motion artifact. The TSD200 is primarily designed for finger attachment, but can be taped to other body locations. The TSD200 comes with a shielded 3-meter cable.

For TSD200C: When the PPG transducer is clipped to the earlobe, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The photodetector operates via incident photons, from an IR transmitter, impacting an IR detector. The incident photons result in a proportional passage of electrons in the detector. The IR detector operates like a photon-controlled current source. The transducer incorporates an appropriate clipping range, with linearity insured for arbitrarily low levels of reflected light. For the expected magnitude of incident infrared light, the photodetector operates in a linear fashion. We have not encountered situations where the detector is operating non-linearly (near saturation).

See also…

Support

Applications

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
VR Eye Tracking Analytics

Complete VR Eye Tracking System

A simple yet powerful solution for setting up eye tracking experiments in VR Complete Virtual Reality Eye Tracking Systems allow you to immerse one or two users in easy-to-create VR scenarios and collect synchronized eye tracking and physiological data for a comprehensive response assessment. Improve your research with meaningful insights on attention and decision making. […]

View All
Latest News

New Citations | Does Smiling Make You Happier? & More

BIOPAC provides software and hardware that allows research teams to study any physiological measure. Here are a few notable studies using BIOPAC equipment for ECG, EDA, and HRV Analysis. Intelligent Interaction Leading to Solutions The research being done in the HCI space is amazing, as scientists continue to make computers more adept at communicating with humans, allowing more […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration