Photoplethysmogram Transducers

Precision Transducer for Research Data Acquisition

Convert biological signals for analysis with MP system or AcqKnowledge®

Request More Info
View Cart “Photo Plethysmogram Amplifier” has been added to your cart.
Photo Plethysmograph Trans TP
Part #: TSD200, TSD200C

The TSD200 photoplethysmogram (PPG) transducer operates with the PPG100C amplifier to record the blood volume pulse waveform via optical (photoplethysmogram) methods.

The TSD200 consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the heme subunit of hemoglobin. When the PPG transducer is placed on the skin, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The PPG waveform peaks when capillary blood volume is maximized.

See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Transducers - Research
Subcategories: General - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


The ergonomic housing design improves contact with the subject and helps reduce motion artifact. The TSD200 is primarily designed for finger attachment, but can be taped to other body locations. The TSD200 comes with a shielded 3-meter cable.

For TSD200C: When the PPG transducer is clipped to the earlobe, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The photodetector operates via incident photons, from an IR transmitter, impacting an IR detector. The incident photons result in a proportional passage of electrons in the detector. The IR detector operates like a photon-controlled current source. The transducer incorporates an appropriate clipping range, with linearity insured for arbitrarily low levels of reflected light. For the expected magnitude of incident infrared light, the photodetector operates in a linear fashion. We have not encountered situations where the detector is operating non-linearly (near saturation).

See also…

Support

Applications

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

New Ventilator Validation Kit for Rapid Development & Field Testing

New Ventilator Validation System Allows Device Manufacturers to Test Ventilator Pressure and Volume System supports rapid development and testing of hardware for COVID-19 treatment Goleta, California – March 24, 2020 BIOPAC Systems, Inc. announced a new Ventilator Validation System for engineering and device manufacturers to use when designing and testing new and existing ventilators for […]

New Citations | VR Hazard Training for Astronauts

Space Flight Simulations Prevent Disasters Under psychological and physical stress, astronauts can put their  mission and crew in danger. Looking into this issue, researchers created a potentially catastrophic spaceflight simulation using a virtual reality environment and recorded the heart rate of participants. Psychophysiological responses to the potentially disastrous flight simulation were recorded using a BIOPAC MP […]

Read All
Request a Demonstration
Request a Demonstration