MP36R System with Workflow License
Part #: MP36RWSW-AWF, ADDKEY-MP36RAWF, MP36RWS-AWF

This MP36R Workflow System ships with

  • MP36R Data Acquisition Unit, which provides four built-in universal amplifiers that can record a wide range of physiological signals. For compatible SS#L Series hardware, see Transducers, Stimulation, and Gas Analysis.
  • AcqKnowledge Acquisition & Analysis Software, an interactive, intuitive program that lets you instantly view, measure, transform, and analyze data. Perform complex data acquisition, stimulation, triggering, and automated analysis routines using simple pull-down menus and dialogs.
  • Workflow Automation (Licensed Feature) functionality significantly saves time and improves consistency. Workflow’s drag-and-drop interface allows you to automate and repeat the analysis steps your protocol requires in an easy-to-use  process without programming or scripting. Batch process multiple files with confidence that they’re all processed using the same procedure. Easily automate routines to expedite signal conditioning and preparation for analysis with a standardized approach. Extract measurements, analyze data and get results faster, for meaningful scientific insights. Save and share workflows with others in your team to help reduce training time and increase standardization and collaboration.

See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Data Acquisition & Analysis: MP160 MP36R - Research
Subcategories: MP36R 4-Channel Systems - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


AcqKnowledge  – click for detailed software overview

  • Features & Enhancements
    • Linked acquisitions
    • Focus Areas
    • Data Integration – Argus Eye Tracking, Noldus FaceReader and The Observer XT, and Smore
    • Animal ECG Boundary Detection
    • Pressure-Volume Loop Analysis – additional license required
    • User Interface Enhancements
      • Tabbed graph interface
      • Textual Value Toolbar on Graph Window
      • Selection Palette Button and Enhancements
      • Window Size Preference
      • Configure Number of Horizontal Measurements
      • Remove Text Annotations from Single Channel
      • Journal Dock Location Option
      • Linked Selections
      • Autoscale single or multiple channels
      • Pin window to top
    • Presets for Rate, Measurements, and Expressions
    • Channel Specific Grids
    • Multi-Channel Simultaneous EEG Analysis
    • Find Cycle Improvements
    • High frame rate camera support
    • Consolidated Hardware Support – MP150, MP36R, B-Alert
    • B-Alert Wireless EEG Enhancements
    • ICG Analysis Improvements

Analysis Routines

  • Detect and Classify Heartbeats
  • Locate ECG Complex Boundaries
  • Heart Rate Variability
  • Gastric Wave Analysis
  • Gastric Wave Coupling
  • Chaos Analysis
    • Detrended Fluctuation Analysis
    • Optimal Embedding Dimension
    • Optimal Time Delay
    • Plot Attractor
  • Correlation Coefficient
  • Electrodermal Activity
    • Derive Phasic EDA from Tonic
    • Event-related EDA Analysis
    • Locate SCRs
  • Electroencephalography
    • Compute Approximate Entropy
    • Delta Power Analysis
    • Derive Alpha-RMS
    • Derive EEG Frequency Bands
    • EEG Frequency Analysis
    • Remove EOG Artifacts
  • Electromyography
    • Derive Average Rectified EMG
    • Derive Integrated EMG
    • Derive Root Mean Square EMG
    • EMG Freq & Power Analysis
    • Locate Muscle Activation
  • Ensemble Average
  • Epoch Analysis
  • Hemodynamic Analysis
    • Classifiers: ABP; LVP; MAP
    • Arterial Blood Pressure
    • ECG Interval Extraction
    • Left Ventricular Blood Pressure
    • Monophasic Action Potential
    • Respiratory Sinus Arrhythmia
  • Impedance Cardiography Analysis
    • Body Surface Area
    • dZ/dt Derive from Raw Z
    • dZ/dt Classifier: B, C, X, Y, and O
    • ICG Analysis
    • Ideal Body Weight
    • PEP Pre-ejection Period
    • dZ/dt Remove Motion Artifacts
  • VEPT- Magnetic Resonance Imaging
    • Artifact Frequency Removal
    • Artifact Projection Removal
    • Median Filter Artifact Removal
    • Signal Blanking
  • Neurophysiology
    • Amplitude Histograms
    • Average Action Potentials
    • Classify Spikes
    • Dwell Time Histograms
    • Find Overlapping Spike Episodes
    • Generate Spike Trains
    • Locate Spike Episodes
    • Set Episode Width and Offset
    • Principal Component Denoising
  • Remove Mean
  • Remove Trend
  • Respiration
    • Compliance and Resistance
    • Penh Analysis
    • Pulmonary Airflow
    • Spectral Subtraction
  • Stim-Response (enhancements)
    • Digital Input to Stim Events
    • Stim-Response Analysis
  • Waterfall Plot
  • Wavelet Denoising

Videos

Workflow Automation

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

Marking and Interpolating Segments

What's New in AcqKnowledge 4.4

AcqKnowledge GUI Overview

User Interface Features in AcqKnowledge 4.3

Easy Experiment Set Up with AcqKnowledge

Introduction to AcqKnowledge | Measurements

Focus Areas | AcqKnowledge Tutorial

AcqKnowledge Playback Mode

Create a Toolbar for AcqKnowledge functions

AcqKnowledge Grid Functionality Tutorial

AcqKnowledge Installation Example

Journal Features in AcqKnowledge

Linked Acquisitions in AcqKnowledge

Preset Options in AcqKnowledge

Setting up Channels in AcqKnowledge

BIOPAC Research Solutions | ECG

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
AcqKnowledge Workflow Action examples

Workflow Automation Licenses

Workflow—A Great Tool for Every Researcher! Automate AcqKnowledge with New Workflow Tool New automation tool significantly saves time and improves consistency with standardized procedures Workflow’s drag-and-drop interface allows you to automate and repeat the signal-conditioning and processing steps your protocol requires in an easy-to-use process without programming or scripting knowledge. Batch process multiple files with confidence […]

View All
Latest News

New Citations | BIOPAC in ANS Research

The autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration