Gas Analysis

Gas Analysis Module

Study Real-Time Oxygen Consumption & Respiratory Exchange Ratio

Now life science educators and their students can obtain real-time oxygen consumption (VO2) and respiratory exchange ratio (RER) measurements using the Gas Analysis Systems for Biopac Student Lab MP3X (airflow accessories required). These face gas analysis systems are components of a complete life science teaching system when used with Biopac Student Lab system hardware, software, and curriculum.

BIOPAC pneumotachs, AFT series, and couplers

Click a product below for more details. Or click here to search the rest of the site.
airflow mask

AFT25 Accessories | Masks & Cap

Part #: RX-AFT25-LARGE, RX-AFT25-MEDIUM, RX-AFT25-SMALL, RX-AFT25-CAP

Airflow mask and cap accessories for the AFT25 adult facemask: Masks do not include T-valve. Available in small, medium, or large.…

filtered mouthpiece

Airflow Filter – Disposable Mouthpiece

Part #: AFT36, AFT36-200

Low flow resistance with high filtration efficiency Use this disposable bacteriological filter with integrated mouthpiece to protect subjects and equipment.…

Factory-cal airflow transducer (CS/CT, IT, RU use SS11LA)

Airflow Transducer

Part #: SS11LB, SS11LA

The SS11LB handheld airflow transducer is intended for human use and can be used to perform a variety of tests relating…

Autoclav. Mouthpiece

Autoclavable Mouthpiece

Part #: AFT8, AFT8-10

This autoclavable mouthpiece connects directly to the TSD117/SS11LA airflow transducer and reduces the cost of disposable parts. (30 mm ID)…

Cal Gas: 4% CO2, 16% O2

Part #: GASCAL

Use this Calibration Gas Cylinder with BIOPAC Gas Analysis Modules. Composition: 4% Carbon Dioxide, 16% Oxygen, balance Nitrogen Cylinder Type:…

Cal Gas: 8% CO2, 21% O2

Part #: GASCAL2

Use this Calibration Gas Cylinder as the second calibration gas when calibrating the GASSYS3 chamber. Composition: 8% Carbon Dioxide, 21%…

airflow cal syringe

Cal. Syringe, 3 liter

Part #: AFT27

The AFT27 3.0 Liter Calibration Syringe is certified to have a volume that meets or exceeds an accuracy of 0.5% of…

AFT6A

Cal. Syringe, 600 ml

Part #: AFT6A

Medium pump syringe used for injecting a precise volume of air (600 ml) through airflow assemblies for precise calibration. The…

Gas & Flow Calibration Mixing Chamber

Calibration Chamber for GASSYS3

Part #: RX-GAS3

This is a short chamber that is used when performing calibration of the GASSYS3 Gas Analysis module. The large chamber…

SS11LB validation and calibration template

Calibration Kit for SS11LB

Part #: FLOWCAL

Optional calibration/validation kit Use FLOWCAL to validate factory calibration of the SS11LB. This kit connects the syringe to the SS11LB, coupler,…

couplers

Couplers

Part #: AFT11A, AFT11B, AFT11C, AFT11D, AFT11E, AFT11F, AFT11H

These couplers connect a variety of air flow port IDs and ODs to transducers, tubing, filters, mixing chambers, and calibration…

Disp. Bact. Filter, 35 mm 10/pk

Part #: AFT4

These disposable airlfow filters remove airborne bacteria; use with the TSD107B and other 35mm breathing circuits. AFT4 VBMax™ filters provide…

AFT1

Disposable Bacterial Filters

Part #: AFT1, AFT1-250

Disposable bacteriological filters for use with 22 mm breathing circuits, such as BIOPAC pneumotach transducers SS11LA, TSD117, or SS11. These filters…

Disposable Face Mask with Adjustable Strap

Disposable Facemask

Part #: AFT10, AFT10S

The AFT10 facemask connects to 22 mm breathing circuits. Connects directly to the AFT1, AFT22 non-rebreathing T valve or TSD117…

AFT2

Disposable Mouthpiece

Part #: AFT2, AFT2-250

These mouthpieces connect to the TSD117 pneumotach transducer and other 22 mm breathing circuits. Connects directly to the AFT1 bacterial…

AFT3

Disposable Noseclip

Part #: AFT3, AFT3-250

These nose clips gently squeeze the nostrils shut to prevent errors when using mouth-breathing circuits. Available in packs of 10 or…

Gas Analysis Module seal

Endcap Gaskets for GASSYS3

Part #: RX-GAS3-GASKET

The RX-GAS3-GASKET is a set of endcap replacement gaskets for the GASSYS3 Gas Analysis Module. Over time the gaskets of…

airflow facemask

Face Mask, Adult, w/T-valve

Part #: AFT25-1, AFT25-2, AFT25-3

This adult facemask with integral non-rebreathing T-valve is a high performance, very low dead space, low airflow resistance mask and…

air flow head for pneumotach transducers TSD117, SS11L, and SS11LA (newer transducers use RX117A-MRI)

Flow Head for Handheld Pneumotach Transducers

Part #: RX117

Sterilizable 22 mm ID/30 mm OD air flow head for older pneumotach transducers TSD117, SS11L, and SS11LA. The material used in the…

pneumotach flow head

Flow Heads – Animal

Part #: RX237B, RX237D, RX237F, RX237H

Detachable pneumotach flow heads in the RXD237 Series are machined from acetal to give good stability with low weight and…

Measure O2 and CO2

Gas Analysis System

Part #: GASSYS3

New! Gas Analysis System—paired with an MP36 unit, airflow transducer, and accessories—provides a lower-cost, compact, simpler, solution suitable for both…

Gas Sampling Interface Kit

Part #: AFT20

Use this gas sampling interface kit to connect the CO2100C or O2100C module with a variety of airflow breathing circuits. Use…

Head Support for AFT21

Part #: AFT24

The AFT24 head support is useful when breathing directly into the AFT21 non-rebreathing T-valve for exercise physiology measurements. The AFT24…

Heated Airflow Pneumotach 1.565 L/sec

Part #: SS50L

The SS50L heated pneumotach can perform a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis. Each…

Heated Airflow Pneumotach 13.333 L/sec

Part #: SS52L

The SS46L-SS52L series pneumotachs can perform a variety of pulmonary measurements relating to airflow, lung volume, and expired gas analysis.…

Heated Airflow Transducer 83 ml/sec

Part #: SS47L

The SS47L is a heated pneumotach suitable for a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis.…

Heated Flow Heads

Part #: RX137B1, RX137C1, RX137D1, RX137E1, RX137F1, RX137G1, RX137H1

The RX137 series are heated airflow head replacements for TSD137 and SS45L-SS52L pneumotach transducers—the head is heated (includes an AC137A power…

Heated Pneumotach Transducer 583 ml/sec

Part #: SS49L

The SS49L heated pneumotach can perform a variety of pulmonary measurements relating to expired gas analysis, airflow, and lung volume.…

Hydrophobic Filter 10/pk

Part #: RX-AFT20-FILTER

Replacement pack of 10 hydrophobic filters for the AFT20 Gas Sampling Interface Kit. Use of Hydrophobic Filters (and Nafion Drying…

Gas sampling drying tube

Nafion Drying Tube 10/pk

Part #: RX-AFT20-NAFION

Replacement pack of 10 Nafion® drying tubes for the AFT20 Gas Sampling Interface Kit. Use of Nafion Drying Tubes (and Hydrophobic Filters)…

Pneumotach Heated Airflow Transducer 166 ml/sec

Part #: SS48L

The SS48L heated pneumotach can perform a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis. Each…

Pneumotach transducer (spirometer) ±2.66 L/sec Airflow

Part #: SS51L

The SS51L pneumotach can perform a variety of pulmonary measurements relating to airflow, lung volume, and expired gas analysis. Each…

Pneumotach Transducer 1.67 L/sec – animal

Part #: SS50LA

This flow transducer is for animals such as medium-sized dogs and includes a detachable flow head (RX237F) and a differential pressure…

Pneumotach Transducer 167 ml/sec – animal

Part #: SS48LA

This very low flow transducer is for animals such as cats or rabbits and includes a detachable flow head (RX237D) and…

Pneumotach Transducer 17 ml/sec – animal

Part #: SS46LA

This very low flow transducer is for animals such as mice or rats and includes a detachable flow head (RX237B) and…

Pneumotach Transducer 50 ml/sec Airflow Heated

Part #: SS46L

The SS46L pneumotach can perform a variety of pulmonary measurements relating to airflow, lung volume, and expired gas analysis. Each…

GASSYSTEM3 Calibration tubing

Regulator Barb Interface GASSYS3

Part #: AFT17

Use this Regulator Barb Interface with Luer lock to connect a regulator (such as GASREG) and GASCAL or GASCAL2 calibration…

gas calibration accessories

Regulator for GASCAL

Part #: GASREG

Use this non-corrosive, two stage regulator with flow control with GASCAL Calibration Gas Cylinder: 4% CO2, 16% O2 or the…

Reusable Mouthpiece 35 mm

Reusable Mouthpiece

Part #: AFT9, AFT9-10

These mouthpieces connect to the TSD107B and other 35mm breathing circuits. Connects directly to the AFT4 bacterial filter or the…

T-valves

Part #: AFT21, AFT22, AFT23

These T-Valves are suitable for exercise physiology, pulmonary function, and even MRI applications. AFT21 35 mm OD: high performance, very low…