Complete EEG Recording and Analysis
Part #: ACKEEG

Electroencephalography Analysis Module
Use the Power of MP Research Systems and AcqKnowledge Software for
a Complete EEG Recording and Analysis Solution!

AcqKnowledge software includes the following automated EEG routines, along with dozens of other automated analysis routines and transformation tools:

  • EEG Frequency Analysis
  • Delta Power Analysis
  • Derive EEG Frequency Bands
  • Derive Alpha RMS
  • Remove EOG Artifacts

Set up and recording is streamlined via intuitive hardware and software controls.

See More...

AcqKnowledge
View Spec PDF

Are You Looking for These?

Part #: ACKEEG
Categories: Software - Research
Subcategories: AcqKnowledge & Upgrades - Research

Details

Compatibility


AcqKnowledge software utilizes guided channel setting dialogs, allowing the user to easily configure all channel data types and parameters. Once parameters are established, recording settings can be saved as a graph template for future use. This allows for instant start up for subsequent recording sessions

During recording, see real-time live raw EEG data as well as real-time filtering or calculation channels. Display EEG frequency bands (alpha, beta, delta, theta) in real-time during recording, or choose from a variety of other filter and calculation settings. Easily insert markers for different stimuli presentation or experimental conditions throughout recording.

EEG data with frequency bands

EEG Data in AcqKnowledge

EEG and other physiological data can also be synchronized to video recording via BIOPAC Camera Systems. With Camera Systems EEG data and Video Data are time linked in AcqKnowledge. Simply scroll through either the video or physiological data to be taken to the corresponding data point in the other file.

AcqKnowledge video sync

Synchronize Physiological Data with Video Data

After recording, take advantage of fully automated EEG analysis routines in AcqKnowledge. Use guided video tutorials to get the most out of all available analysis tools.

EEG Automated Analysis Package Overview

EEG Frequency Analysis

This analysis divides the EEG signals into fixed-width time epochs and performs various feature extractions to examine the power within the EEG signals.

EEG Frequency analysis provides the following measures for each user defined epoch:

  • Mean Power
  • Median Frequency
  • Mean Frequency
  • Spectral Edge
  • Peak Frequency

See the EEG Frequency Analysis in Action:

Delta Power Analysis

Provides total power of EEG signal that occurs within the delta frequency band. Delta power can be an indicator of sleep/wakefulness and other conditions.

Derive EEG Frequency Bands

Generates five standard EEG bands: Alpha, Beta, Theta, Delta, and Gamma from raw EEG data.

Derive Alpha RMS

Derive Alpha RMS constructs an integrated RMS waveform from an alpha EEG signal. Alpha RMS is the windowed root mean square value of the signal using a window width of 0.25 seconds.

Remove EOG Artifacts

Record a channel of EOG with your EEG data to take advantage of the EOG artifact removal tool. Cleaned EEG data can then be used for further analysis with more accurate results.

EEG with EOG Artifact Removal

See EOG Artifact Removal in Action:

AcqKnowledge EEG Analysis Routines are customizable and can be applied to multiple channels. Easily select which channels to include in EEG Analysis Routines. Analyze multiple channels simultaneously!

EEG multi-channel analysis in AcqKnowledge

See Multiple Channel Analysis in Action:

 EEG Analysis Routine parameters can also be customized. Set custom frequency bands, or adjust thresholds in the Preferences menu.

Select Frequency parameters EEG

Additional Tools for Recording EEG in the MRI

Record EEG data in the MRI by adding on specialized MRI Smart Amplifiers. The EEG100C-MRI amplifier and cable/filter set allow for cleaner data recordings in the MRI environment. After recording, take advantage of automated MRI data processing tools in AcqKnowledge.

Get Started!

Record up to 16 channels of high-fidelity EEG and other physiological data either wirelessly with BioNomadix or B-Alert Wireless EEG, or via standard wired amplfiers. Contact BIOPAC today to customize a complete package with amplifiers, leads, electrodes, and/or transducers for your application.

Videos

Support

Downloads/Resources

Knowledge Base

Manual

Recommended Items

Spotlight On
free BIOPAC webinar

A Complete Solution for Eye Tracking Experiments in Virtual Reality

BIOPAC will present a complete and integrated solution that includes eye tracking analytics, the ability to link physiological data, and implementation of user interaction. A user-friendly interface combined with examples enables even novices to get started right away! Learn how eye tracking analytics tools can save considerable time and effort with data interpretation.

You Will Learn:
• How the system works
• How you can use eye tracking to add interactivity in VR
• How to perform a stimulus presentation paradigm in VR
• How to work with 360 videos and images
• Eye tracking data analysis—heatmaps, gaze replay, fixation times, gaze intersection, etc.

Watch Live on January 27

Register Now
Latest News

New Citations | Does Smiling Make You Happier? & More

BIOPAC provides software and hardware that allows research teams to study any physiological measure. Here are a few notable studies using BIOPAC equipment for ECG, EDA, and HRV Analysis. Intelligent Interaction Leading to Solutions The research being done in the HCI space is amazing, as scientists continue to make computers more adept at communicating with humans, allowing more […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration