BIOPAC® Systems, Inc. Logo

EEG Analysis Software Module

The Premier Data Acquisition & Analysis Program: AcqKnowledge®

Software module for advanced analysis

Request More Info
View Cart “Electrode Cap Sys., TouchProof” has been added to your cart.
Complete EEG Recording and Analysis
Part #: ACKEEG

Electroencephalography Analysis Module
Use the Power of MP Research Systems and AcqKnowledge Software for
a Complete EEG Recording and Analysis Solution!

AcqKnowledge software includes the following automated EEG routines, along with dozens of other automated analysis routines and transformation tools:

  • EEG Frequency Analysis
  • Delta Power Analysis
  • Derive EEG Frequency Bands
  • Derive Alpha RMS
  • Remove EOG Artifacts

Set up and recording is streamlined via intuitive hardware and software controls.

See More...

AcqKnowledge
View Spec PDF

Are You Looking for These?

Part #: ACKEEG
Categories: Software - Research
Subcategories: AcqKnowledge & Upgrades - Research

Details

Compatibility


AcqKnowledge software utilizes guided channel setting dialogs, allowing the user to easily configure all channel data types and parameters. Once parameters are established, recording settings can be saved as a graph template for future use. This allows for instant start up for subsequent recording sessions

During recording, see real-time live raw EEG data as well as real-time filtering or calculation channels. Display EEG frequency bands (alpha, beta, delta, theta) in real-time during recording, or choose from a variety of other filter and calculation settings. Easily insert markers for different stimuli presentation or experimental conditions throughout recording.

EEG data with frequency bands

EEG Data in AcqKnowledge

EEG and other physiological data can also be synchronized to video recording via BIOPAC Camera Systems. With Camera Systems EEG data and Video Data are time linked in AcqKnowledge. Simply scroll through either the video or physiological data to be taken to the corresponding data point in the other file.

AcqKnowledge video sync

Synchronize Physiological Data with Video Data

After recording, take advantage of fully automated EEG analysis routines in AcqKnowledge. Use guided video tutorials to get the most out of all available analysis tools.

EEG Automated Analysis Package Overview

EEG Frequency Analysis

This analysis divides the EEG signals into fixed-width time epochs and performs various feature extractions to examine the power within the EEG signals.

EEG Frequency analysis provides the following measures for each user defined epoch:

  • Mean Power
  • Median Frequency
  • Mean Frequency
  • Spectral Edge
  • Peak Frequency

See the EEG Frequency Analysis in Action:

Delta Power Analysis

Provides total power of EEG signal that occurs within the delta frequency band. Delta power can be an indicator of sleep/wakefulness and other conditions.

Derive EEG Frequency Bands

Generates five standard EEG bands: Alpha, Beta, Theta, Delta, and Gamma from raw EEG data.

Derive Alpha RMS

Derive Alpha RMS constructs an integrated RMS waveform from an alpha EEG signal. Alpha RMS is the windowed root mean square value of the signal using a window width of 0.25 seconds.

Remove EOG Artifacts

Record a channel of EOG with your EEG data to take advantage of the EOG artifact removal tool. Cleaned EEG data can then be used for further analysis with more accurate results.

EEG with EOG Artifact Removal

See EOG Artifact Removal in Action:

AcqKnowledge EEG Analysis Routines are customizable and can be applied to multiple channels. Easily select which channels to include in EEG Analysis Routines. Analyze multiple channels simultaneously!

EEG multi-channel analysis in AcqKnowledge

See Multiple Channel Analysis in Action:

 EEG Analysis Routine parameters can also be customized. Set custom frequency bands, or adjust thresholds in the Preferences menu.

Select Frequency parameters EEG

Additional Tools for Recording EEG in the MRI

Record EEG data in the MRI by adding on specialized MRI Smart Amplifiers. The EEG100C-MRI amplifier and cable/filter set allow for cleaner data recordings in the MRI environment. After recording, take advantage of automated MRI data processing tools in AcqKnowledge.

Get Started!

Record up to 16 channels of high-fidelity EEG and other physiological data either wirelessly with BioNomadix or B-Alert Wireless EEG, or via standard wired amplfiers. Contact BIOPAC today to customize a complete package with amplifiers, leads, electrodes, and/or transducers for your application.

Videos

Support

Downloads/Resources

Knowledge Base

Manual

Recommended Items

Spotlight On
AcqKnowledge Workflow Action examples

Workflow Automation Licenses

Workflow—A Great Tool for Every Researcher! Automate AcqKnowledge with New Workflow Tool New automation tool significantly saves time and improves consistency with standardized procedures Workflow’s drag-and-drop interface allows you to automate and repeat the signal-conditioning and processing steps your protocol requires in an easy-to-use process without programming or scripting knowledge. Batch process multiple files with confidence […]

View All
Latest News

New Citations | BIOPAC in Exercise Physiology

Exercise physiology is the study of the body’s response to physical activity. Research in exercise physiology allows for insights in health and for a better understanding of the functions of the body at work. Here are some recent studies in exercise physiology that utilized BIOPAC tools for their research… Effect of exercise on electrocardiographic parameters […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration