BioNomadix 2Ch Wireless ECG Transmitter

BioNomadix 2Ch Wireless ECG Set
Part #: BN-ECG2-T

The Dual Wireless ECG BioNomadix transmitter is specifically designed to measure Electrocardiogram (ECG) data on one or both channels. Collect data from just LEAD I and LEAD II to generate LEAD III and all the augmented leads (aVR, aVL and aVF).

ECG signal data is transmitted at a rate of 2,000 Hz, providing an extremely high resolution ECG waveform at the receiver’s output. Raw data from the pair is bandlimited from 0.05 Hz to 150 Hz, to provide a very high quality recording. The matched pair incorporates internal, non-distorting, highpass and lowpass filters to provide for high quality amplification of the complete ECG waveform and associated complexes. The high signal to noise ratio and high time-based sampling resolution permit the pair to be used for exacting heart rate variability studies.
The transmitter can be used with the Logger or with a matched Receiver to emulate a “wired” connection from subject to computer, with all the benefits of a fully-wireless recording system.
See More...

Are You Looking for These?

Part #: BN-ECG2-T

Details


Using AcqKnowledge’s equation generator, a six-lead ECG can be generated from the two recorded ECG leads from the module pair. Use AcqKnowledge software to provide a complete Lead II ECG analysis. The software automatically scores the data and extracts the measurements of interest on a cycle-by-cycle basis. The results are automatically exported to Excel or pasted in the Journal file. AcqKnowledge also includes a fully automated HRV analysis feature. The HRV analysis provides values for VLF, LF, HF, VHF, sympathetic, and vagal, as well as the sympathetic / vagal balance.

ECG100C ECG amplifier and AcqKnowledge automated ECG analysis ECG analysis 3d surface plot (waterfall) of Lead II ECG recording

Using AcqKnowledge, wide bandwidth ECG data can be filtered to lower values to accommodate high quality ECG signal isolation even in the presence of extensive subject motion.

Biopotential amplifier/transmitter signal to noise ratio is very high (in excess of 70 dB), as the noise floor of the amplifier/transmission system is only 0.9 µV rms (bandwidth of 0.05 Hz to 150 Hz).

The module set has a fixed gain of 2,000. The largest ECG signal which can be measured is 10 mV P-P, the smallest is less than 1 µV rms.

Interference with other recording modules or systems is greatly minimized because the transmitter is completely battery operated and operates totally independently of any other recording grounds or power sources. The recording transmitter is also extremely safe to use, because there is no physical connection to supply mains.

Due to battery operation of the wireless transmitter and close proximity to the subject’s body, common-mode rejection ratio is extremely high, considerably in excess of any typical wired ECG recording system. Accordingly, notch filters to remove mains interference (50 or 60 Hz) are typically not required.

The transmitter attaches to the subject’s body (torso) via stretchy Velcro strap or stretch-mesh BioNomadix Shirt (see accessories). The exterior transmitter body dimensions (W x H x D) are approximately 6 cm x 4 cm x 2 cm and it weighs approximately 54 grams.

The transmitter’s battery can provide power for up to 72 hours of continuous operation.


The new BioNomadix series of wireless, wearable physiology monitoring devices for life science research are available for a wide range of signals, including ECG, EEG, EOG, EMG, EGG, Respiration, Pulse, Temperature, Electrodermal Activity, Impedance Cardiography, Accelerometry, and Gyro. BioNomadix are typically dual-channel units, offering either two of the same signal or a combination of signals.

BioNomadix noninvasively record high-quality, full-bandwidth data while comfortably allowing subjects to move freely in natural indoor environments. Each BioNomadix device consists of two parts, a transmitter that is worn by the subject to amplify and send the physiological data, and a receiver module. BioNomadix transmitters use digital transmission and short leads or transducers placed close to the signal source to provide excellent signal quality. BioNomadix are configured for specific signal types, so you don’t have to adjust settings on the hardware or software for high quality data.

Multiple BioNomadix can be used to provide the optimum signal combination for a research study requiring biopotential or transducer signals.

When used with a BIOPAC MP System, up to 16 channels of BioNomadix data can be recorded for multi-subject or multi-parameter protocols. The system also works with multiple MP150 systems or third-party data acquisition hardware via an isolated power supply module (IPS100C). AcqKnowledge software adds the power of sophisticated automation and scoring routines for each signal type, plus customization options.

BioNomadix accessory items include transducers, electrode leads, and a custom, pocketed stretch-mesh shirt to comfortably hold multiple devices in place. The shirt has zippers placed for easy access to electrode sites and is available from extra small to extra large.

Developed and manufactured by BIOPAC Systems Inc., a leader in life science data acquisition and analysis, the new BioNomadix series delivers all the benefits of a wireless solution with the signal quality & integrity of a wired system. BioNomadix provides a cost-efficient option for uncompromised wireless physiological subject monitoring.

Videos

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

Support

Application Notes

Downloads/Resources

Knowledge Base

Recommended Items

WHAT'S NEW

Citation Spotlight | Menstrual Cycle-Driven Hormones & Brain Changes

BIOPAC is pleased to recognize the first-author contribution of Viktoriya Babenko,...
View All News

Join the BIOPAC Community

Stay Current

Stay Connected

Request a Demonstration
Request a Demonstration

    What is your purchasing timeframe?

    By using this form you agree to receive emails from BIOPAC and with the storage and handling terms of your data.