BIOPAC® Systems, Inc. Logo

fNIR Sensors

Safe, Affordable, Noninvasive Cognitive Function Assessment

Wireless functional near infrared optical imaging system

fNIR Sensor Replacement for Optical Brain Imaging
Part #: RXFNIR-4, RXFNIR-PED, fNIR-Phantom

Functional near infrared optical brain imaging forehead (prefrontal cortex) sensor pads connect to fNIR System Imager unit to provide real-time oxy-Hb, deoxy-Hb, and raw data values for each channel measurement area.

PART # | Channels | Detectors | Emitters | Inter-optode Distance | Interface

RXFNIR-4 Split | 4 | 4 | 2 |25 mm | all Imagers

RXFNIR-PED Pediatric | 2 | 2 | 1 |20 mm |all Imagers

FNIR-PHANTOM | mimics optical properties of brain tissue to test sensor performance |≥ Imager 1100

Note: RXFNIRA was discontinued October 2017; sensor was Adult | 16 |10 | 4 | 25 mm | tethered Imager 1200 and required RXFNIR-SEN-CBL.

See More...

Clean Data

Raw light intensity & oxygenation data, modern noise reduction methods & analysis options

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: fNIR Optical Brain Imaging - Research
Subcategories: Sensor Options - Research

Details

Compatibility


Photo-detectors: Silicon photodiode with integrated trans-impedance preamp

Photo-emitters: 730 nm/850 nm dual wave-length LED

Material: silicone rubber over-molded

Phantom Sensor

The phantom sensor material mimics optical properties of brain tissue, and it is used to test the system to make sure that the fNIR sensor is detecting correctly.

  • The phantom is included with the fNIR400 System and can be added to fNIR100A, fNIR200A, or fNIR300A Systems.

See the fNIR COBI Manual for details on how to run a Self-Check to test signal levels at each channel and generate a report that indicates performance on each channel.

fNIR Phantom self-test

Cleaning fNIR Imagers and Sensors

All generations and models: Use an alcohol swab to gently wipe the surface of the fNIR Imager unit or sensor.

Support

Application Notes

Applications

Downloads/Resources

Knowledge Base

Manual

Scripts

Recommended Items

Spotlight On
short, lightweight pinch leads

LEAD115 Lighter Lead Series

New series of unshielded 45 cm electrode leads with thin cable; suitable for facial EMG and other areas where lighter, shorter lead cables are required. Use for female Touchproof connectors to pinch clip connectors—connect electrodes to either a C-series amplifier or an MEC. The pinch connectors are light weight and the lead cable tinsel wire […]

View All
Latest News

MEAP and BIOPAC used to quantify rapid changes in cardiovascular state

The new issue of Psychophysiology has a study “Quantifying rapid changes in cardiovascular state with a moving ensemble average” using MEAP for preprocessing/analysis and BIOPAC hardware and software for data collection, display, and storage. The proof of concept study demonstrates a viable method for the adoption of ICG measures across the field of psychophysiology. MEAP (moving ensemble […]

News Citations—fMRI & Temperature, Postpartum Depression, and Fibromyalgia

BIOPAC provides software and hardware that allow for research teams to record and analyze respiration activity in physiological experimentation. Here are a few notable studies covering MRI, ECG, and Laser Doppler Flow measurement. fMRI & Thermal Perception: The neural mechanisms underlying thermal perception (how hot or cold we perceive the temperature to be) have not been fully […]

Read All
Request a Demonstration
Request a Demonstration