BioNomadix Wireless Wearable Physiology Logger

Research-Quality Data in an Easy-to-Use, Wearable, Wireless Package

Easy-to-use, easy-to-wear 24-hour data logger

Logger supports freedom of movement & complex experimental design

Wireless Physiology Data Logger
Part #: BN-LOGGER, BN-LOGGER-1, BN-LOGGER-2, BN-LOGGER-3, BN-LOGGER-ADD

Offering the industry’s only system that delivers a comprehensive, 24-hour data logging solution in an easy-to-use, easy-to-wear package, the BioNomadix Logger® truly delivers “physiology anywhere.” The BioNomadix Logger is the perfect tool for applications that demand greater degrees of subject freedom and complex experimental design.

BioNomadix Loggers wirelessly record physiological data as subjects freely and naturally live their lives. Get the real-world data your application demands. The compact Logger device provides

  • Data from up to three dual-channel wearable BioNomadix Transmitters*
  • Built-in Accelerometer
  • color display for visual feedback
  • speaker for auditory feedback
  • vibration for haptic feedback
  • voice journal for participant comments
  • event markers
  • alarms
  • flexible external antenna to help improve radio performance

Options include Logger unit with AcqKnowledge and 1, 2, or 3 dual-signal Transmitters; Logger unit with AcqKnowledge (for built-in accelerometry or use with existing Transmitter); or Logger unit only (add to existing Transmitter-Receiver set and AcqKnowledge 4.4.1 or above).

See More...

Are You Looking for These?

Part #: N/A

Details

Updated Features

  • Improved Standby—Doubled Shelf-Life: Power consumption is lower when the logger is put into sleep mode; overall shelf life before needing to be connected to a charger should be around twice as long.
  • Buttons: new style provides a better “feel” with more tactile feedback when pressed.
  • Reset—Force Reboot: Recessed reset button (opposite the USB port) may be activated (using an unbent paper clip) to force the logger to reboot.

Internal Accelerometer

Use the Logger’s built-in internal accelerometer function for monitoring activity and detecting motion. This data is logged with the other transmitter signals being recorded and can also be imported into AcqKnowledge software for analysis. Various data ranges and thresholds can be set to adjust the accelerometer sensitivity. To access the internal accelerometer, highlight this entry in the Data Setup screen and press the “Select”button. Use the navigation buttons to choose and modify the accelerometer settings. To see a visual sample of the accelerometer motion in progress, select the “Check data” option.

Note  Internal accelerometer data cannot be recorded simultaneously with Tap Mode (see below). If the tap interface is enabled, the raw accelerometer data is unavailable in the log. In order to record the raw internal accelerometer data into the log, Tap interface must be disabled (Configure > Tap interface).

Tap Mode

Tap Mode is useful when a subject needs to interact with the unit but does not have direct access to the screen buttons, such as when the Logger unit is inside a shirt pocket. The accelerometer options include “Tap Mode” settings which enable haptic (tapping) feedback to the Logger unit. With Tap Mode enabled, Logger functions such as waking up the unit, inserting markers during acquisition, or initiating 30-second audio memo recordings can be accomplished by lightly striking or “tapping” the Logger unit. The unit will vibrate/beep briefly in response to the “tap” input. Normally, the default Tap Mode settings (Tap Threshold, Tap Time, Tap Latency and Tap Window) are sufficient for optimal response to the “tap” input. However, it may be necessary in certain cases to adjust these parameters in order to increase or decrease “tap” sensitivity.


 

Physiology Data Logger

Researchers can connect up to three transmitters to the Logger for data logging or with BioNomadix receivers operate in the lab and view data on a computer running AcqKnowledge. They can also Sync the BioNomadix Logger with GPS for a correlation between physiological and location data. AcqKnowledge software includes powerful automation, scoring, and measurement tools to help you interpret data for meaningful results—as cited in thousands of peer-reviewed publications.

Dual-signal wireless BioNomadix Transmitters include:

ECG-ECG EOG-EOG PPG-EDA SKT-SKT DYN-EMG
EEG-EEG EGG-EGG RSP-ECG dZ-Dt Acceleromtry
EMG-EMG EDA-EDA RSP-RSP Heel-Toe Goniometry

Experience the Freedom of Discovery

BioNomadix – Physiology When, Where, and How You Want

Imagine recording up to 10 channels of data from participants in the controlled environment of the lab and then sending them home to record data while they live their lives. A variety of Logger packages are available to suit any lab requirements. Sample packages are shown here…Request info or contact BIOPAC to discuss your particular requirements.

Add the power & flexibility of BioNomadix Logging to your lab!

New Users Existing Users Logger Add-on
Logger and Software for Current Research System– BioNomadix Logger
– AcqKnowledge Software
– Transmitter(s): choose 1, 2, or 3 per logger
Logger and Software for Current Research System– BioNomadix Logger
– AcqKnowledge Software Upgrade
Logger Device for Current MP150 System & BioNomadix System
– BioNomadix Logger

Researchers have the option of using just the logger or combining it with BioNomadix wireless transmitters and receivers and BIOPAC’s MP150 Data Acquisition System, AcqKnowledge software and accessories, for a complete, cost effective and easy-to-use yet sophisticated life science data acquisition and analysis system.

Contact BIOPAC to learn more or request a quotation!

* Existing BioNomadix devices require a firmware upgrade to be compatible with Loggers—please see BN-FIRMWARE-UPDATE or contact BIOPAC for details.

Videos

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

BioNomadix Wireless Amplifiers | Wireless Physiology Monitoring

Eye Tracking & Physiology - Synchronized Data

BIOPAC Research Solutions | ECG

BIOPAC Research Solutions | EMG

Support

Application Notes

Applications

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

WHAT'S NEW

Citation Spotlight | Menstrual Cycle-Driven Hormones & Brain Changes

BIOPAC is pleased to recognize the first-author contribution of Viktoriya Babenko,...
View All News

Join the BIOPAC Community

Stay Current

Stay Connected

Request a Demonstration
Request a Demonstration

    What is your purchasing timeframe?

    By using this form you agree to receive emails from BIOPAC and with the storage and handling terms of your data.