All Products Applications Curriculum Knowledge Base Videos News Content
* CLEANING GUIDELINES * [Knowledge Base]

External Cleaning / Disinfecting Instructions For any BIOPAC Systems data acquisition, amplifier, or accessory module: To clean the surface of the module: wipe lightly with a dry, lint-free cloth, or…

No Products Found

102 – Biopotential Amplifier Testing With CBLCAL [Application Note]

CBLCAL is a device used to check the accuracy of BIOPAC biopotential amplifiers. CBLCAL stands for cable calibration and is used to calibrate EMG, EOG, EEG, ECG, and ERS amplifiers.…

109 – 3-, 6-, and 12-Lead ECG [Application Note]

An electrocardiogram (ECG) is a graphic recording of the changes occurring in the electrical potentials between different sites on the skin (leads) as a result of cardiac activity. Depolarization of…

110 – Amplifier Baseline Offset Adjustment [Application Note]

Offset refers to the zero point or baseline of a signal. BIOPAC biopotential amplifiers (including the DA100) are preset at the factor to Offset 0. When recording in AC mode,…

114b – Pneumotach Transducer – TSD107B [Application Note]

The TSD107B* pneumotach is a highly linear, wide range, airflow transducer. Using the TSD107B and a DA100C amplifier, with the MP150/100 and AcqKnowledge, the user can perform a variety of…

12-Lead ECG Recordings [Advanced Feature]

To record a continuous 12-lead ECG, use a WT100C Wilson Terminal to create a virtual reference electrode when measuring the transverse plane (i.e., precordial) ECG components [V1, V2, V3, V4,…

122 – Power Spectrum Analysis [Application Note]

AcqKnowledge can be used to obtain the power spectrum of any time domain waveform. The power spectrum indicates the power of each frequency component of the source time domain waveform.…

126 – Wireless Remote Monitoring – TEL100C-RF [Application Note]

The TEL100C-RF remote monitoring system can monitor a wide range of physiological activity, including ECG, EOG, EEG, GSR, SKT, PPG, RSP, and surface EMG. Specialized signal processing of physiologic variables…

129 – Heart Rate Variability [Application Note]

This application note explains statistical measures and geometric measures in heart rate variability studies. See also Application Note 233: HRV – Preparing Data for Analysis for details on recording good…

135 – Airflow Transducer Calibration – SS11LA [Application Note]

The SS11LA can be used to measure respiratory flow over a wide range of subjects and conditions. The SS11LA includes an optically clear detachable flow head (RX117) for easy cleaning and…

135 – Pneumotach Transducer – TSD117 [Application Note]

The TSD117 can be used to measure respiratory flow over a wide range of subjects and conditions. The TSD117 includes an optically clear detachable flow head (RX117) for easy cleaning…

141 – Tri-Axial Accelerometer Calibration – BSL [Application Note]

Tri-axial accelerometers are high-level output transducers requiring no additional amplification since the amplifier is built into the transducer. They connect directly to the MP3X unit of the Biopac Student Lab…

142 – Rate Detector Algorithm in AcqKnowledge [Application Note]

The AcqKnowledge Rate Detector is critical to the ability of AcqKnowledge to extract information from physiological data that has a degree of periodicity. Physiological data which can be investigated using…

148 – Automated ECG Analysis [Application Note]

ECG Analysis An electrocardiogram (ECG) is a graphical recording of the changes occurring in the electrical potentials between different sites on the skin as a result of cardiac activity. The…

148 – Automated ECG Analysis – BSL [Application Note]

An electrocardiogram (ECG) is a graphical recording of the changes occurring in the electrical potentials between different sites on the skin as a result of cardiac activity. The electrical activity…

172 – Multilead ECG Cable – SS29L [Application Note]

The SS29L Multi-Lead ECG Cable permits high-resolution multi-lead ECG recordings. The lead configuration allows the user to simultaneously record Leads I, II, III, aVR, aVL, aVF, plus one precordial chest…

187 – Electrodermal Response Guidelines – EDA100C (GSR100C) [Application Note]

This application note explains how to record electrodermal activity (EDA/GSR) and observe electrodermal response (EDR) changes with the EDA100C Electrodermal Activity amplifier, GSR100C Galvanic Skin Response amplifier, or TEL100C telemetry…

190 – Micro-Electrode Amplifier Guidelines – MCE100C [Application Note]

The MCE100C micro-electrode amplifier module is useful for a wide range of physiological recording applications that require the use of micro-electrodes, such as cellular single channel analysis. Micro-electrodes, due to…

206 – Continuous 12-Lead ECG [Application Note]

To record a continuous 12-lead ECG, use a WT100C Wilson Terminal to create a virtual reference electrode when measuring the transverse plane (i.e., precordial) ECG components [V1, V2, V3, V4,…

230 – Connections for Physiological Signals in an MRI [Application Note]

For Magnetic Resonance Imaging (MRI) applications, it can be important to collect auxiliary physiological data in conjunction with the Nuclear Magnetic Resonance (NMR) image data. This auxiliary data includes physiological…

241 – Recording EMG data in an fMRI [Application Note]

This application note is concerned with the recording of real-time EMG during a fMRI investigation. The following BIOPAC products were used for this measurement: MP150WSW data acquisition system with AcqKnowledge…

242 – Recording ECG Data in an fMRI [Application Note]

This application note is concerned with the recording of real-time ECG during a fMRI investigation. The following BIOPAC products were used for this measurement: MP150WSW data acquisition system with AcqKnowledge®…

253 – BBS | Getting Started with BIOPAC Basic Scripting [Application Note]

BIOPAC Basic Scripting Customize – Acquisition setup and analysis Automate – Acquisitions and perform batched analysis Simplify – Add dialogs and prompts to assist users Expedite – Reduce analysis time…

258 – BIOPAC MRI Smart Amplifier Performance [Application Note]

This application note is concerned with the recording of real-time physiological data, from a human subject, during fMRI, using BIOPAC’s series of MRI Smart Amplifiers: ECG Electrocardiogram Amplifier for MRI…

265 – MRI Artifact Removal from ECG Waveforms [Application Note]

ECG waveforms can be “scrubbed” of MRI artifact with the judicious application of hardware and software tools. However, even with specialized hardware filtering (as with the MRI-specific amplifiers), some residual…

268 – Metabolic Analysis Systems and Propane-based Verification [Application Note]

This application note examines a conventional equipment setup for metabolic measurements. The setup is exposed to a propane-based, combustion verification source that emulates subject’s steady-state consumption of oxygen and production…

279 – ECG and EDA Recording in 7-Tesla fMRI [Application Note]

This application note addresses EDA and ECG measurements performed in a Siemens 7T fMRI. BIOPAC MRI Smart Amplifiers were used to record ECG LEADII and EDA from the fingertips. Standard…

280 – ETHUSB Communication – Mac OS X 10.7 or above [Application Note]

The following is a brief overview of the steps to verify that the USBETH is installed correctly—for more detailed instructions, see the PDF. Depending on when ETHUSB  was purchased, it may have…

282 – Subject Electrical Stimulation in fMRI and MRI [Application Note]

This application note is concerned with the implementation of subject electrical stimulation in the fMRI and MRI for the purposes of psychophysiological research. The setup presented physically limits the stimulation…

293 – Displaying BPM Through Seven Segment Displays [Application Note]

This Application Note demonstrates how to sample and display calculation channel data through external devices such as LED’s or 7-segment displays via UIM100C digital output ports. In this exercise, BPM…

4T Human Physiology Conference [Page]

This conference has ended – was July 24-26, 2017 Learn from Leading Researchers How to Record and Analyze Human Physiology Data  Join your colleagues in Santa Barbara to meet with…