BIOPAC® Systems, Inc. Logo

pH Probe, BNC-M

Request More Info
pH Probe, BNC-M
Part #: RXPROBE-01

The electrode provides approximately a single digit pH value change for every 5 mV change in the electrode reading, either positive or negative depending on whether the pH is above 7 or below it.
~ A neutral buffer solution of pH 7 reads about 0 mV
~ A solution with a pH of 10 reads about 15 mV
~ A solution with a pH of 3 reads about 20 mV

See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: RXPROBE-01
Categories: Tissue Baths & Accessories - Education, Tissue Baths & Accessories - Research
Subcategories: Accessories - Education, Accessories - Research

Details

Compatibility


This double junction pH probe measures pH within the range of 0-14.

Probe interface options:

  • BSL Systems
    • Order the SS68L pH Probe Transducer for direct connection to a BSL MP3X Data Acquisition Unit
    • Order the BSL-TCI21 Interface for pH Probe to use an existing (BNC terminated) pH probe
  • MP Research Systems
    • Order SS68L and TCI114 to interface with the DA100C

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

New Citations | Rehabilitating the Rehab Industry & More!

BIOPAC provides software and hardware that allows engineers to study the body. Here are a few notable studies using BIOPAC equipment for Biomedical Engineering research. Rehabilitating the Rehab Industry Could physical therapy be done from the comforts of your own home? If possible, this would open the door for more people with all sorts of ailments to […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration