BIOPAC® Systems, Inc. Logo

fNIRS Imaging Education System

fNIRS Optimized for Education

Easy to Use—short prep & learning curve

Cutting-edge NIRS technology with user-friendly tools

Request More Info
View Cart “fNIR Sensors 2000” has been added to your cart.
fNIR Education System
Part #: fNIR103E

fNIRS Imaging Systems are stand-alone functional brain imaging solutions for continuous NIR spectroscopy (NIRS). They provide an in-lab cognitive function assessment and eliminate a great many of the drawbacks of a functional MRI.

fNIRS optical imaging technology measures neural activity and hemodynamic response in the prefrontal cortex. Subjects wear an fNIR sensor (IR light sources and detectors mounted in a flexible band) on the forehead that detects oxygen levels in the prefrontal cortex and provides real-time values for oxyhemoglobin and deoxygenated hemoglobin. It provides a continuous and real-time display of the oxygen changes as the subject performs different tasks.

Subjects can sit in front of a computer and take a test or perform mobile tasks. fNIRS applications include Brain Computer Interface, Human Performance Assessment, Neurorehabilitation, Depth of Anesthesia Monitoring, and more.

fNIR Education Systems for continuous NIR spectroscopy (NIRS) include

  • Imager 2000E control unit (6-optodes max)
  • Sensor and Cable
    • fNIR2000E includes one 6-channel sensor and one sensor cable
  • fNIRSoft and COBl Software
    • Software for data collection and analysis (the included software may change with a 30-day notice; if the included the software changes the existing licensees will receive the replacement software)
  • Lessons to record NIRS measurements from the forehead and the forearm at two wavelengths, 730 nm for deoxy-Hb and 850 nm for oxy-Hb
See More...

Best Value

  • Lowest price in the industry with cutting-edge engineering
  • Highest quality material & robust data collection

Powerful & Friendly

  • Implement the most advanced analysis tasks without any programming

Cleaner fNIRS Data

  • Near-optode Sensors reduce systemic artifact
  • Lower noise—almost twice as efficient LEDs
  • Least Prone to motion artifacts

NIRS data acquisition
View Spec PDF

Are You Looking for These?

Part #: fNIR103E
Categories: fNIRS Optical Brain Imaging - Education, fNIRS Optical Brain Imaging - Research
Subcategories: fNIR Systems - Research

Alternatives
For the same Platform

Details

Compatibility


fNIRS Education SystemfNIRS lessons prepare students for professions in clinical and research settings, including:

  • Psychology
  • Neuroscience
  • Sports medicine
  • Physical therapy
  • Speech pathology
  • Education
  • Biomedical engineering

Imager 2000E Specs

  • Max Sources: 2
  • Max Detectors: 6
  • Max Sampling Frequency: 2 Hz
  • Wireless: no
  • Synchronization ports: no
  • Dimensions: 106 mm x 32 mm x 106 mm

The fNIRS data combines with other physiological variables such as ECG, respiration, cardiac output, blood pressure, electrodermal activit, and stimulus response markers. AcqKnowledge software provides automated analysis tools for event-related potentials (ERP) and ensemble averaging. Combining the fNIRS data with other physiological signals provides researchers with a detailed subject assessment.

fNIRSoft (fS) Software & COBI Studio

fS is a software package for use with the 2000E Imager for Education Systems. Use fS viewer and data management tools to process, analyze, and visualize functional near infrared spectroscopy (fNIRS) signals. View data in real time and perform post-acquisition analysis.

COBI Studio “Cognitive Optical Brain Imaging” software is designed for performing serial experiments and makes it easy to start recording, and to save all experimental data (fNIRS, synchronization markers from external presentation stimuli, etc.) in a standardized way.


For additional details, review these items under the Support tab:

  • fNIR and COBI Studio User Guide for data collection guidelines
  • fNIRSOFT User Manual for a step-by-step guide for using fS, with an introduction to fNIRS technology and a discussion of the Modified Beer Lambert Law (MBLL) that is integral to the analysis of fNIR spectroscopy signals

Videos

fNIRS for Education

fNIR COBI Tutorial

fNIR Webinar | Combining Optical Brain Imaging and Physiological Signals to Study Cognitive Function

Support

Downloads/Resources

Knowledge Base

Manual

Recommended Items

Spotlight On
free BIOPAC webinar

STRESS | Measuring Related Physiological Changes

How do physiological signals change when we experience stress? How can we monitor those changes continuously so we can aim to improve our quality of life? BIOPAC will present a wide array of noninvasive and continuous measurements of stress-related physiological signals and provide in-depth guidance about best practices for recording and data analysis.

You Will Learn How To:
• Select the right measurements and obtain good data
• Choose which signals to record-including fNIRS, ECG, EDA, Respiration, Blood pressure, etc.
• Recognize the importance of each signal in the context of the stress response
• Analyze the respective signals with live examples
• Take measures best suited for short-term vs. long-term recording

LIVE WEBINAR on October 7 at 8AM PT/11AM ET

Register Now
Latest News

New Citations | Marking Events with BIOPAC

BIOPAC offers complete systems for life science research and education—human, animal, or in vivo studies, as well as powerful software and automated analysis including industry-standard data acquisition amplifiers, transducers & electrodes. BIOPAC can be used inside or outside the lab to measure physiology anytime, anyplace. Impact of Movie Editing on Perceptual Conflict Mechanisms Our ability to watch and understand films effortlessly […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration