Module Extension Cables

Request More Info
DA100C or B-Series Amp to 2 mm
Part #: MEC100, MEC100C, MEC110, MEC110C, MEC111, MEC111C

Add lead length & protect your system

Module extension cables increase the distance between subject and recording system, allowing increased subject movement and comfort. Each 3-meter extension cable attaches to one amplifier; electrodes and transducers plug into the extension cable’s molded plastic input plug. Includes a clip for attaching to a subject’s belt loop or clothing. MEC series extension cables contain no ferrous parts (less the removable clothing clip).

3 m Module Extension Cables

  • For 100C Series Modules
    MEC100C C-Series Transducer Amplifier to Touchproof
    MEC110C C-Series Biopotential Amplifier to Touchproof
    MEC111C C-Series Biopotential Amplifier to Touchproof, Protected
  • For 100B Series Modules
    MEC100 DA100C or B-Series Amplifier to 2 mm
    MEC110 B-Series Amplifier to Touchproof
    MEC111 B-Series Biopotential Amplifier to Touchproof, Protected
See More...

BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Cables & Accessories - Research
Subcategories: Amplifier Extension Cables - Research

Details

Compatibility


Use MEC110C or MEC100C when you simply need to increase the lead length to the amplifier.

IMPORTANT SAFETY NOTE: The MEC100 series is not to be used on humans when they are undergoing electrosurgery or defibrillation. In fact, no BIOPAC equipment should be connected to human subjects during the course of defibrillation or electrosurgery.

The MEC111C or MEC111 is required for the protection of your MP System and Biopotential amplifiers when electrocautery or defibrillation equipment is used while recording data.

There are passive protection circuits built into MEC111C. These protective elements are designed to protect the biopotential amplifier from damage, assuming heart defibrillation pulses are introduced to the monitored subject. The MEC111C design incorporates 10 kohm series resistance elements, on each conductor, that also terminate in a transient absorber. With this design, potentially harmful defibrillation pulses are suppressed prior to encountering the biopotential amplifier input.

All other cables support direct point-to-point wiring, and incorporate no active or passive protective components.

When using MEC110C with EBI100C or NICO100C, the mapping of port function to color is as follows:

I Out: Brown
Vin+: Red
Vin: White
I In: Green

(I In) also galvanically ties to amplifier ground; the GND ground (Black) port on the MEC110C is typically ignored in this application.

The following figure details typical setup to measure cardiac output and impedance cardiography measures using MEC110C with NICO100C or EBI100C with LEAD110C, CBL204, and Electrodes.

lead connections NICO or EBI

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

BIOPAC Systems Helps STARK Industries Launch VITAL Ventilator for NASA JPL

BIOPAC’s ventilator testing equipment and expertise supports STARK Industries’ effort to manufacture, validate, and test NASA JPL’s VITAL Ventilators Goleta, California – June 16, 2020 BIOPAC Systems, Inc. announced a partnership with STARK Industries, LLC to provide ventilator validation and testing equipment for the mass production of ventilators. STARK Industries was awarded a global license […]

New Citations | Go Inside with Imaging Solutions from BIOPAC!

Physiological Lung Testing in the MRI to Find Damage from Military Deployments Our military veterans who served overseas in the middle east often come home with scars both seen and unseen. For some vets, unfortunately, these scars can take the form of lung damage sustained due to sandstorms, burn pits, and other high toxicity situations apparent […]

Read All
Request a Demonstration
Request a Demonstration