Module Extension Cables

DA100C or B-Series Amp to 2 mm
Part #: MEC100, MEC100C, MEC110, MEC110C, MEC111, MEC111C

Add lead length & protect your system

Module extension cables increase the distance between subject and recording system, allowing increased subject movement and comfort. Each 3-meter extension cable attaches to one amplifier; electrodes and transducers plug into the extension cable’s molded plastic input plug. Includes a clip for attaching to a subject’s belt loop or clothing. MEC series extension cables contain no ferrous parts (less the removable clothing clip).

3 m Module Extension Cables

  • For 100C Series Modules
    MEC100C C-Series Transducer Amplifier to Touchproof
    MEC110C C-Series Biopotential Amplifier to Touchproof
    MEC111C C-Series Biopotential Amplifier to Touchproof, Protected
  • For 100B Series Modules
    MEC100 DA100C or B-Series Amplifier to 2 mm
    MEC110 B-Series Amplifier to Touchproof
    MEC111 B-Series Biopotential Amplifier to Touchproof, Protected

$165.00 - $295.00

Clear selection
   Request More Info
BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Cables & Accessories - Research
Subcategories: Amplifier Extension Cables - Research

Details

Compatibility


Use MEC100C or MEC110C when you simply need to increase the lead length to the amplifier.

The MEC111 or or MEC111C are required for the protection of your MP System and Biopotential amplifiers when electrocautery or defibrillation equipment is used while recording data.

IMPORTANT SAFETY NOTE: The MEC100 series is not to be used on humans when they are undergoing electrosurgery or defibrillation. In fact, no BIOPAC equipment should be connected to human subjects during the course of defibrillation or electrosurgery.

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Noninvasive BP Amp with Hemodynamics

Noninvasive Blood Pressure Amp with Hemodynamics

Simple and noninvasive—finger sensor provides accurate & immediate feedback: arterial BP, cardiac output, fluid and hemodynamic status The NIBP100D-HD noninvasive blood pressure system provides a continuous, beat-to-beat, blood pressure signal recorded from the fingers of a subject. Measure noninvasive BP parameters (BP, sBP, dBP, mBP, and PR) plus hemodynamic parameters (PPV, SVV, CO, CI, SV,SI, SVR, […]

View All
Latest News

New Citations—ECG Personal Identification, Cognitive Decline and Exercise, & Mechanical Impulses

Personal Identification: Researchers from Yonsei University recently performed a study testing the viability of using ECG signals for individual identification, much like a password or key. Their study investigated experiments that recorded ECG after exercise and estimated the recognition potential of these signals. ECG was measured from subjects using the BIOPAC MP150 data acquisition system […]

Ford uses fNIR Systems to test driving performance

Ford ran an experiment in which it used fNIR devices to monitor individual’s driving performance. The drivers were then given a score and provided insights into how their driving could be improved, via an app. Ford ran the study for four months using 40 Ford Fiestas and encompassed various types of weather, time of day, and […]

Read All
Request a Demonstration
Request a Demonstration