Blood Pressure Cuff Transducers

Precision Transducer for Research Data Acquisition

Convert biological signals for analysis with MP system or AcqKnowledge®

Request More Info
Blood Pressure Cuff Transducers
Part #: SS19LB, SS19L

SS19L Series noninvasive blood pressure cuffs come complete with adjustable cuff (circumference range 25.4 to 40.6 cm), pump bulb, and pressure sensor, and pressure gauge; SS19LB has on-screen gauge only, SS19L has mechanical gauge (manometer) only. The pressure sensor is contained in the connector housing (DB9) and connects to the cuff via a 3 meter air hose (Luer-Lok fittings). Only a single calibration point (at 0 mmHg) is required.

The cuff transducer assembly can be ordered as

SS19LB for on-screen gauge display only—does not include mechanical gauge

SS19L for a mechanical gauge

Important! Hardware and Software Compatibility varies—see “Interface” in spec PDF for compatibility details.

See More...

BIOPAC sphygmomanometer
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Transducers - Education, Transducers - Research
Subcategories: Blood Pressure & Accessories - Education, Blood Pressure & Accessories - Research

Equivalents
With a different Platform

Details

Compatibility


SS19LB onscreen BP gauge

Gauge color can be set under Lesson Preferences.

Use the BP Cuff transducer with the SS30L stethoscope for the evaluation of systolic and diastolic blood pressure. When the stethoscope is used to record the Korotkoff sounds it is easy to obtain very accurate and repeatable results. For alternate cuff sizes, see the RX120 Cuff Series.

Note – SS19LB/LA  is not compatible with MP45 Systems (USB chip conflict); use SS19L with MP45 Systems.

Calibration

The built-in pressure transducer requires an initial calibration. see specs for detailed instructions.

 

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Cardiac Output amplifier

NICO Smart Amplifier

The NICO Smart Amplifier is specifically designed to measure thoracic impedance for performing noninvasive cardiac output measurements. The amplifier terminates in two connectors for impedance (Z) and its derivative (dZ), and has a 3 m cable that connects directly to an AMI100D Amplifier Input Module. Use with EL526 strip electrodes and CBL246 adapter or with EL500 […]

View All
Latest News

New Citations | BIOPAC in ANS Research

The autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration