BIOPAC® Systems, Inc. Logo

Biopac Student Lab Ultimate Systems

Request More Info
BSL Ultimate System - Win
Part #: BSLULT-W, BSLULT-M

BSL System with MP36 and hardware for 18 guided lessons plus 22 dynamic lessons and student-designed experiments. The Biopac Student Lab ULTIMATE system provides the ultimate teaching solution and enables students to perform 18 Biopac Student Lab Guided Lessons, found in the BSL Laboratory Manual, and includes BSL PRO functionality for BSL PRO Lessons, advanced student projects, research, and to create or use additional lessons.

The ULTIMATE system includes all the features and functionality of the ADVANCED system, plus all of our most frequently used transducers and a human-safe stimulator. This system is ideal for multi-disciplinary labs where a number of different courses share the same lab equipment. The ULTIMATE System includes transducers suitable for human subjects.

See More...

BIOPAC Physiology Teaching Tools
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Ultimate - Education

Alternatives
For the same Platform

Details

Compatibility


Free Student Download – Students can use this free BSL software to prepare for class by reading lesson or watching videos, and can also analyze, share, and submit data.

The Biopac Student Lab Ultimate System Includes:

  • MP36 Data Acquisition Unit with USB Cable, DC Adapter (110V/60Hz or 220V/50Hz) & Cord (US or Euro)
  • BSL 4 Software (Lessons and PRO)
  • MANBSL4 BSL 4 Laboratory Manual (English) – includes introductory physiology text, guided procedure, and data analysis for BSL Lessons L01-L20
  • Searchable PDF Manuals and Tutorials (BSL PRO, Instructor’s Guide, Answer Key, etc.)
  • SS2LB Shielded Lead Set x2
  • SS29L Multi-lead ECG Cable
  • EL503 Disposable vinyl electrodes (100/pk)
  • ELPAD Electrode Abrading Pads (10/pk)
  • GEL1 Electrode Gel (57 g tube)
  • SS57LA EDA w/Electrode Pinch Leads
  • EL507A EDA Dry Disposable Electrodes (100/pk)
  • GEL101A Isotonic Gel for EDA/GSR
  • STMHUM Human-Safe Stimulator 0-100 V
  • SS10L Push-button Hand Switch
  • SS11LB Factory-calibrated Medium Airflow Transducer
  • AFT36  Disposable Filtered Mouthpiece (10/pk)
  • AFT3 Disposable Noseclips (10/pk)
  • SS13L Pressure Transducer
  • SS19LB Blood Pressure Cuff Transducer (on-screen gauge)
  • SS30L  Stethoscope
  • OUT1A Headphones
  • SS61L Finger Twitch Transducer
  • SS25LB Hand Dynamometer
  • SS4LA Photoplethysmogram (Pulse) Transducer
  • SS5LB Respiratory Effort Transducer
  • SS6L Fast Response Temperature Transducer
  • PAPER1 Colored paper for Visual Stim (9 pk)
  • TAPE1 Single-sided Adhesive Tape

Perform 40 or more lessons with the Ultimate System:

Muscular

L01 Standard & Integrated EMG
L02 Motor Unit Recruitment & Fatigue
H06 Finger Twitch
H07 EMG Contractions—Active Learning
H27 Facial EMG
H34 Electrogastrogram (from human)
H36 Muscular Biofeedback
Cardiovascular
L05 Components of the ECG (Lead II)
L06 Leads I, II, III & Einthoven’s Law
L07 ECG & Pulse
L16 Blood Pressure & Korotkoff
L17 Heart Sounds & Cardiac Events
H01 12-Lead ECG
H04 Blood Pressure (Isometric or Straining exercise)
H05 WAnT Wingate Test
H08 Dive Reflex—Active Learning
H23 Signal Averaged ECG
H32 Heart Rate Variability
Pulmonary Function
BSL08 Respiratory Cycle
BSL12 Pulmonary Function: Vol. & Capacities
BSL13 Pulmonary Flow Rates: FEV and MVV
BSL15 Aerobic Exercise Physiology
Neurophysiology
L03 EEG Relaxation & Brain Rhythms
L04 Alpha Rhythms in the Occipital Lobe
L09 GSR and Polygraph
L10 EOG Eye Movement, Saccades & Fixation
L11 Reaction Time & Learning
L14 Biofeedback: Relaxation & Arousal
H03 Nerve Conduction (ulnar nerve)
H10 EEG & Hemispheric Asymmetry
H11 Mirror Test: EDA Sensory motor learning
H12 EOG Saccades & Displacement
H13 EOG Visual Tracking
H14 Ocular Fixation while reading
H15 Ocular Fixation while viewing an image
H16 Reaction Time
H24 Habituation
Bioengineering
H02 Compartmental Modeling
H20 Filtering
H33 FFT Fast Fourier Transform
Join thousands of satisfied teachers and students! Biopac Student Lab User List

Videos

Biopac Student Lab Teaching Systems

Biopac Student Lab Student Download

What's in the Box | BSL Starter Systems

Support

Application Notes

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
Cardiac Output amplifier

NICO Smart Amplifier

The NICO Smart Amplifier is specifically designed to measure thoracic impedance for performing noninvasive cardiac output measurements. The amplifier terminates in two connectors for impedance (Z) and its derivative (dZ), and has a 3 m cable that connects directly to an AMI100D Amplifier Input Module. Use with EL526 strip electrodes and CBL246 adapter or with EL500 […]

View All
Latest News

New Citations | BIOPAC in Exercise Physiology

Exercise physiology is the study of the body’s response to physical activity. Research in exercise physiology allows for insights in health and for a better understanding of the functions of the body at work. Here are some recent studies in exercise physiology that utilized BIOPAC tools for their research… Effect of exercise on electrocardiographic parameters […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration