BIOPAC® Systems, Inc. Logo

Biopac Student Lab Advanced Systems

The Gold Standard for Life Science Instruction

Advanced life science teaching solution

The preferred application for better science and greater discovery

Request More Info
BSL Advanced System - Win
Part #: BSLADV-W, BSLADV-M

BSL System with MP36 and hardware for 14 guided lessons plus 19 dynamic lessons and student-designed experiments. The ADVANCED System is extremely flexible and can be used across multiple disciplines including human physiology, pharmacology, psychophysiology, exercise physiology and a great many more. This system comes with everything you need (except the computer) to conduct the most widely studied responses in physiology labs, including experimental measurements of ECG, EEG, EMG, EOG, EDA, Pulse, Airflow, Respiratory Effort, Lung Volume, Reaction Time and Skin Temperature. The BSL Lab Manual and onscreen guides take you through each step, including initial setup, software options, and lesson procedures.

See More...

Teach the Way You Want

Create your own lessons, no programming. New Curriculum Management System.

Increase Student Engagement

Students record data from their own bodies, animals, or tissue preparations. +65 experiments.

Fast, Easy Set-Up & Operation

Reduces setup time by 90%. Guided lessons w/ on-screen instructions, video demos & sample data.

BSL Advanced Teaching System - Win
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Advanced - Education

Alternatives
For the same Platform

Details

Compatibility


Free Student Download – Students can use this free BSL software to prepare for class by reading lesson or watching videos, and can also analyze, share, and submit data.

The BSL PRO software allows you to create your own lessons (no programming required), or use the system for advanced student projects and research.

The Biopac Student Lab Advanced System includes:
  • MP36 Data Acquisition Unit with USB Cable, DC Adapter (110V/60Hz or 220V/50Hz), and Power Cord (US or Euro)
  • BSL 4 Software (Lessons and PRO)
  • 2 x Electrode Lead Sets – SS2LB
  • Disposable Electrodes (100/pk) – EL503
  • Abrasive Pads (10/pk) – ELPAD
  • Airflow Transducer, factory-calibrated – SS11LB
  • Disposable Filtered Mouthpieces (10/pk) – AFT36
  • Disposable Noseclips (10/pk) – AFT3
  • Electrodermal Activity (EDA) Lead – SS57L
  • EDA Dry Electrodes (100/pk) – EL507A
  • Isotonic Gel for EDA/GSR – GEL101A
  • Pulse Plethysmograph Transducer – SS4LA
  • Respiratory Effort Transducer – SS5LB
  • Temperature Transducer – SS6L
  • Tape – TAPE1
  • Hand Switch – SS10L
  • Headphones – OUT1
  • Colored Paper Set (for BSL Lesson 9) – PAPER1
  • BSL Laboratory Manual MANBSL4
  • Install disk includes Searchable PDF Manuals and Tutorials (BSL PRO, Instructors Guide, Answer Key, etc.)

Perform 33 or more lessons with the Advanced System:

Muscular

  • BSL1 Standard & Integrated EMG
  • H07 EMG Contractions – Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram (from Human)
  • H36 Muscular Biofeedback

Cardiovascular

  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • BSL7 ECG & Pulse
  • H05 WAnT Wingate Test
  • H08 Dive Reflex – Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability

Pulmonary Function

  • BSL8 Respiratory Cycle
  • BSL12 Pulmonary Function: Vol. & Capacities
  • BSL13 Pulmonary Flow Rates: FEV and MVV
  • BSL15 Aerobic Exercise Physiology

Neurophysiology

  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL9 GSR and Polygraph
  • BSL10 Eye Movement, Saccades & Fixation
  • BSL11 Reaction Time & Learning
  • BSL14 Biofeedback: Relaxation & Arousal
  • H10 EEG & Hemispheric Asymmetry
  • H11 Mirror Test- EDA Sensory Motor Learning
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image
  • H16 Reaction Time
  • H24 Habituation

Biomedical Engineering

  • H02 Compartmental Modeling
  • H20 BME Filtering
  • H33 FFT Fast Fourier Transform

Videos

Biopac Student Lab Teaching Systems

Biopac Student Lab Student Download

What's in the Box | BSL Starter Systems

Support

Application Notes

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
BIOPAC Evoked Response Module

ERS Smart Amplifier

The ERS Evoked Response Smart Amplifier is an extremely low noise differential amplifier that accurately amplifies very small potentials, such as those associated with stimulus/response, startle response, ABR auditory brainstem response, somatosensory evoked response, signal-averaged recordings, and nerve conduction velocity recordings. BIOPAC’s new Smart Amplifiers are designed for great data. Smart Amplifiers improve performance by […]

View All
Latest News

New Citations | BIOPAC in Ergonomics

Whether using specialized equipment, performing repetitive tasks, or simply going about our daily work routine, the effects of design in our environment as well as the tools we use and the way we use them can impact our health, work performance, and quality of life. Here are a few studies that have recorded and analyzed […]

EDA Guide Available

BIOPAC’s comprehensive EDA Guide provides an introduction to Electrodermal Activity (EDA or GSR) and details topics including: EDA Complex: SCL, SCR, tonic, phasic, specific SCR, non-specific SCR Participant Prep & Electrode Placement Data Recording tips Automated EDA Analysis Routines Digital input to Stim Events Stim-Response Analysis Derive Phasic EDA from Tonic Event-related EDA Analysis Locate […]

Read All
Request a Demonstration
Request a Demonstration