BIOPAC® Systems, Inc. Logo

Biopac Student Lab Animal Systems

The Gold Standard for Life Science Instruction

Complete small animal physiology intro teaching solution

The preferred application for better science and greater discovery

Request More Info
BSL Animal Physiology - Win
Part #: BSLAPH-W, BSLAPH-M

BSL System with MP36 and hardware for 6 guided lessons plus 25 dynamic lessons and student-designed animal experiments. Students can work with frogs, earthworms, and other animals while studying the heart, muscle function, and membrane potential.

Increase your lab options by adding on the Gas Analysis System (GASSYS3) and analyze expired O2 and CO2 from both animals and humans. Add on the dissolved O2 probe (RXPROBE-O2A) and measure the oxygen consumption of a goldfish!

See More...

Increase Student Engagement

Students record data from their own bodies, animals, or tissue preparations. +31 experiments.

Fast, Easy Set-Up & Operation

Reduces setup time by 90%. Guided lessons w/ on-screen instructions, video demos & sample data.

Empowers Better Teaching

Extensive out-of-class resources. New Curriculum Management System. 3 Systems to meet a range of needs.

BSL Animal Physiology Teaching System - Win
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Animal Physiology - Education

Alternatives
For the same Platform

Details

Compatibility


Free Student Download – Students can use this free BSL software to prepare for class by reading lesson or watching videos, and can also analyze, share, and submit data.
The Biopac Student Lab Animal Physiology & Intro Human Physiology Teaching System provides a wide range of options for animal, tissue, and basic human physiology experiments. Many lessons allow students to study both animal and human species for comparative physiology teaching programs.

The BSL Animal Physiology & Intro Human Physiology system includes:

  • BSL 4 Software (Lessons and PRO)
  • BSL Laboratory Manual MANBSL4
  • Searchable PDF Manuals and Tutorials (BSL PRO, Instructor’s Guide, Answer Key, etc)
  • MP36 Data Acquisition Unit with USB Cable, DC Adapter (110 V/60 Hz or 220 V/50 Hz) & Cord (US or Euro)
  • 2 x High-Impedance Cable – BSLCBL8
  • Disposable Electrodes (100/pk) – EL503
  • Abrasive Pads (10/pk) – ELPAD
  • Interface for Dissolved Oxygen Probe (compatible with RXPROBE-O2A or Vernier) – BSL-TCI16
  • Force Transducer (variable range) – SS12LA
  • Electrode Lead Shielded/Red X 2 – LEAD110S-R
  • Electrode Lead Shielded/White X 2 – LEAD110S-W
  • Electrode Lead Unshielded X 2 – LEAD110
  • Low Voltage Stimulator Adapter – OUT3 (BNC to MP36 built-in stimulator)
  • Nerve Chamber – NERVE2
  • Nerve Stimulator Cable – BSLCBL2A
  • Nerve Recording Cable – BSLCBL4B
  • 3 x Needle Electrodes – EL452
  • Stimulator Electrodes – ELSTM2

Perform 30 or more lessons with this core package:

Muscular

  • A02 Frog Gastrocnemius
  • A05 Visceral Smooth Muscle
  • A11 Resting Potential from Crawdad Manual
  • A15 Earthworm Smooth Muscle
  • BSL1 Standard & Integrated EMG
  • H07 EMG Contractions – Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram

Cardiovascular

  • A04 Frog Heart
  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • H08 Dive Reflex – Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability

Pulmonary Function 

  • with your existing probe or add RXPROBE-02A Dissolved Oxygen probe
    A07 Fish Respiration & Q10 (oxygen consumption of a goldfish)

Neurophysiology

  • A01 Frog Pith & Prep
  • A03 Frog Nerve
  • A06 Cockroach Nerve
  • A08 Action Potential
  • A14 CPG Hornworm
  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL10 Eye Movement, Saccades & Fixation
  • H10 EEG & Hemispheric Asymmetry
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image

Biomedical Engineering

  • H20 BME Filtering
  • H33 FFT Fast Fourier Transform

Learn more about the Animal Physiology and Intro Human Physiology system.

Videos

BSL Systems | Animal Physiology Teaching System

Biopac Student Lab Teaching Systems

Biopac Student Lab Student Download

Support

Application Notes

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
BIOPAC Evoked Response Module

ERS Smart Amplifier

The ERS Evoked Response Smart Amplifier is an extremely low noise differential amplifier that accurately amplifies very small potentials, such as those associated with stimulus/response, startle response, ABR auditory brainstem response, somatosensory evoked response, signal-averaged recordings, and nerve conduction velocity recordings. BIOPAC’s new Smart Amplifiers are designed for great data. Smart Amplifiers improve performance by […]

View All
Latest News

New Citations | BIOPAC in Psychophysiology Research

The mind and body work together in many ways and psychophysiology research provides insight to these connections. BIOPAC has a variety of systems to power your emotion, arousal, stress, cognitive assessment, group interaction, startle, and other psychophysiology research. Here are some recent studies that have used BIOPAC systems for psychophysiological research… Skin conductance, facial EMG, […]

Seenel Imaging and BIOPAC Systems, Inc. Announce a Global Partnership

           For immediate release: January 4, 2023 Amiens, France and GOLETA, California, USA Seenel Imaging SAS and BIOPAC Systems, Inc. have formed a long-term global partnership to distribute MedelOpt®, Seenel Imaging’s groundbreaking wearable neuroimaging device for the neuroscience research market. Seenel Imaging, based in France, continues its international expansion by partnering with BIOPAC Systems, […]

Read All
Request a Demonstration
Request a Demonstration