BIOPAC® Systems, Inc. Logo

Biopac Student Lab Human Physiology Systems

The Gold Standard for Life Science Instruction

Complete, customizable human physiology teaching solution

Request More Info
BSL Human Physiology - Win
Part #: BSLHPY-W, BSLHPY-M

BSL System with MP36 and hardware for 11 guided lessons plus 14 dynamic lessons and student-designed Human Physiology experiments. Use the power of the BSL Human Physiology Teaching System to conduct the most widely studied responses in physiology teaching labs. Lessons target the circulatory system, respiratory system, muscular function, brain function, ANS, exercise physiology and neuronal physiology. Dynamic experiments with students as subjects increase interest and retention. Promote student inquiry with advanced options or develop user-defined lessons and research projects. Perform analysis online or off; sophisticated algorithms provide beat-by-beat analysis of the primary physiological signals.

See More...

Increase Student Engagement

Students record data from their own bodies. +25 experiments.

Fast, Easy Set-Up & Operation

Reduces setup time by 90%. Guided lessons w/ on-screen instructions, video demos & sample data.

Empowers Better Teaching

Targets circulatory system, respiratory system, muscular function, brain function, ANS, exercise physiology & neuronal physiology.

BSL Human Physiology Teaching System- Win
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Human Physiology - Education

Alternatives
For the same Platform

Details

Compatibility


Free Student Download – Students can use this free BSL software to prepare for class by reading lesson or watching videos, and can also analyze, share, and submit data.

The BSL Human Physiology system comes with the following:

  • BSL 4 Software (Lessons and PRO)
  • Searchable PDF Manuals and Tutorials (BSL PRO, Instructor’s Guide, Answer Key, etc.)
  • BSL Laboratory Manual MANBSL4
  • MP36 Data Acquisition Unit (USB) with DC Adapter (110V/60Hz or 220V/50Hz) & Cord (US or Euro)
  • 2 x Electrode Lead Sets – SS2LB
  • Disposable Electrodes (100/pk) – EL503
  • Abrasive Pads (10/pk) – ELPAD
  • Hand Dynamometer – SS25LB
  • BP Cuff Transducer – SS19LB
  • Electronic Stethoscope Transducer – SS30L
  • Air Flow Transducer, factory-calibrated – SS11LB
  • Disposable Filtered Mouthpieces (10/pk) – AFT36
  • Disposable Noseclips (10/pk) – AFT3

Perform 25 or more lessons with this core package:

Muscular

  • BSL1 Standard & Integrated EMG
  • BSL2 Motor Unit Recruitment & Fatigue
  • H07 EMG Contractions – Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram
  • H36 Muscular Biofeedback

Cardiovascular

  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • BSL16 Blood Pressure & Korotkoff Sounds
  • BSL17 Heart Sounds & Cardiac Events
  • H08 Dive Reflex – Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability

Pulmonary Function

  • BSL12 Pulmonary Function: Vol. & Capacities
  • BSL13 Pulmonary Flow Rates: FEV and MVV

Neurophysiology

  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL10 Eye Movement, Saccades & Fixation
  • H10 EEG & Hemispheric Asymmetry
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image

Biomedical Engineering

  • H20 BME Filtering
  • H33 FFT Fast Fourier Transform

Learn more about the Human Physiology system.

Videos

BSL Systems | Human Physiology Teaching System

Biopac Student Lab Teaching Systems

Biopac Student Lab Student Download

BSL 4 Analysis Software UI and Tools

BSL 4 Analysis Software - Analysis Example

Support

Application Notes

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
free BIOPAC webinar

New Scent Delivery System for Research

Researchers can now easily add an olfactory element to expand general psychophysiology studies, enrich virtual and augmented environments, or examine how scent perception affects a variety of applications. BIOPAC’s new Scent Delivery System (SDS200-SYS), connects to an MP160 Research System with AcqKnowledge, and delivers up to eight scents to participants.

You Will Learn How To:
• Add olfactory stimulation to any experiment
• Optimize setup to get the best results
• Combine different types of stimulation

LIVE WEBINAR on November 4 at 8AM PT/11AM ET

Register Now
Latest News

New Citations | Physiological Measures to Understand Stress

BIOPAC provides software and hardware that allows research teams to study physiological measures related to stress. Here are a few notable studies using BIOPAC equipment for ECG, EDA, and EEG/ERP. Moms Moderating Stress Can relaxation techniques help lower stress on both mother and fetus? Using an MP36R Data Acquisition system to record ECG and EDA, this study […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration