Top 15 Questions to ask before investing in a Data Acquisition System What are the physiological variables of research interest? What are the conditions in which physiological data will be…
Search
The O2100C module can be used to perform real-time oxygen concentration monitoring. The O2100C module may be used to perform analysis of expired air during the course of a pulmonary…
The CO2100C Carbon Dioxide Measurement Module records quickly varying carbon dioxide concentration levels. The CO2100C module is equipped with a variable speed pump to adjust the flow over a wide…
The CO2100C module can be used to perform real-time carbon dioxide concentration monitoring. The CO2100C module may be used to perform analysis of expired air during the course of a…
The HLT100C module is used to interface all high-level output transducers to the MP System and provides 16 input and 2 output channels. The HLT100C is similar in function to…
This application note details the AcqKnowledge file format for the Macintosh platform. This document describes file formatting for AcqKnowledge versions 3.0-3.7.3. This File Format document does not apply to version…
This document describes file formatting for all Windows versions of AcqKnowledge 3.9.x or below, BSL 3.7.0 or below, and BSL PRO v3.7.0 or below. The File Format allows the user…
This application note describes how to use the AcqKnowledge software to automatically determine inspired and expired lung volume on a breath-by-breath basis. The Application Note assumes that you have a…
This application note describes how to use the Biopac Student Lab PRO software to automatically determine inspired and expired lung volume on a breath-by-breath basis. The application note assumes that…
This application note describes how to set up and use the TSD116A and B switches. The TSD116 series switches are used for remote event marking or for psychophysiological response tests.…
A major factor affecting breath-by-breath respiratory gas measurements is the response time of the O2100C and CO2100C modules. Although the CO2100C module has somewhat faster response times than the O2100C…
This application note will demonstrate how to perform automated analyses of your tissue bath data. This will yield the responses to the data you have collected. The MP100 can be…
This application note will demonstrate how to perform automated analyses of your tissue bath data. This will yield the responses to the data you have collected. The Biopac Student Lab…
MP System (MP160, MP150, MP100) stimulation features provide a powerful vehicle for outputting a variety of wave shapes of varying duration, coincident with the data acquisition process. This application note…
This document explains how to obtain an integrated EMG from raw EMG data, using the Biopac Student Lab Pro software. Integrated EMG can either be derived online in real time…
This upgrade procedure assumes you already have a BIOPAC ISA100 card installed in your computer that has been successfully running the MP30 acquisition unit.
The Upgrade Procedure for BSL 2 to BSL 3 assumes you have a BIOPAC ISA100A card installed in your computer that has been successfully running the MP30 acquisition unit and…
The AcqKnowledge software has many features that allow the user to perform a wide variety of left ventricular pressure measurements. Some of these measurements can be performed as the data…
The Biopac Student Lab PRO software has many features which allow the user to perform a wide variety of left ventricular pressure measurements. Some of these measurements can be performed…
This application note provides an analysis example that shows how the MP System (with MP150 or MP100) can be used to investigate processes of speech motor control in normal speech…
The LDF100C Laser Doppler Flow Module section covers the following topics: Features & Controls Operating Restrictions – Cautions and Warnings Installation and Operation User Maintenance Specifications General Overview of the…
AcqKnowledge 3.5 is a 32-bit application. AcqKnowledge 3.5 will not run under Windows 3.1, but AcqKnowledge 3.26 is still available for Windows 3.1. The program uses a new…
The SS29L Multi-Lead ECG Cable permits high-resolution multi-lead ECG recordings. The lead configuration allows the user to simultaneously record Leads I, II, III, aVR, aVL, aVF, plus one precordial chest…
The SS30L Electronic Stethoscope will allow you to record and listen to heart sounds and Korotkoff sounds. The Electronic Stethoscope has a microphone built into the tubing that connects…
MP150 and MP100 System stimulation features provide a powerful vehicle for outputting a variety of waveforms of varying duration, coincident with the data acquisition process. Often, a stimulation voltage in…
For years, cardiologists examined paper charts of ECG signals to create an averaged ECG complex. They took each individual cardiac cycle, measured each part of the complex with a ruler,…
This Application Note describes how to connect the Narco F60 or F2000 myograph to the Biopac Student Lab MP30/35/36 unit using the SS-KIT-IN, available from BIOPAC.
This Application Note summarizes the software changes implemented in BSL PRO v3.6. For BSL Lesson upgrade features, see Application Note #163.
The Biopac Student Lab software has a very useful and powerful integration tool within its calculation menu. Using the Integrate function you will be able to calculate airflow volume. You…
The MP Research Systems have the capability to do extensive online and offline analysis of raw blood flow data. The subject is typically an animal. By interfacing the MP150/100 with existing…
Precise real-time Oxygen Consumption (VO2) and Respiratory Exchange Ratio (RER) measurements can be performed with the MP150/100 System and the CO2100, O2100 and DA100 modules with some airflow accessories. When…
Signals from transducer catheters are suitable for high-fidelity pressure monitoring with high-frequency response data acquisition systems such as the MP Research System (using MP150 or MP100 unit), and are therefore…
BIOPAC Systems, Inc. has a solution to compatibility issues for communication between the iMac and G3 line of Apple Computers and the MP30 and MP100 units.
The ability to collect and display psychological responses via a self-reporting mechanism can be implemented using the TSD115 Variable Assessment Transducer with the MP150 or MP100 System. The MP Research System…
This application note explains how to record electrodermal activity (EDA/GSR) and observe electrodermal response (EDR) changes with the EDA100C Electrodermal Activity amplifier, GSR100C Galvanic Skin Response amplifier, or TEL100C telemetry…
The MCE100C micro-electrode amplifier module is useful for a wide range of physiological recording applications that require the use of micro-electrodes, such as cellular single channel analysis. Micro-electrodes, due to…
This application note explains how to automatically control the digital I/O lines of the MP150/100 to trigger other devices (i.e. turn a device on and off at predetermined intervals). The…
The MP100 and MP150 systems employ separate methods to acquire data in order to accommodate the differences in sampling speeds and aggregate rates between the two systems. Both systems are…
Cardiac Output can be determined, noninvasively, by employing electrical bio-impedance measurement techniques. Electrical bio-impedance is simply the characteristic impedance of a volume of tissue and fluid. In the case of…
The program uses a new installation procedure. The software will operate on OS 8.6 and higher with a USB adapter.
A startle response is elicited by an intense stimulus with a sudden or abrupt onset such as the slamming of a door. The function of the startle response is to…
This application note guides you through the analysis process only, based on the following signals: ECG, Zo and dZ/dt. It is not intended to assist in the acquisition process. See…
The following application note will describe how to use the AcqKnowledge software to create Arbitrary waveforms for the STM100C Stimulator Module. We recommend that you use this application note in…
This application note describes how to configure SuperLab to use it with AcqKnowledge. The SuperLab interface card will be used to generate digital I/O and AcqKnowledge will be used to…
The AcqKnowledge Peak Detector is a software analysis tool used for the purposes of automatically performing specific measurements on data in an AcqKnowledge data file. The Peak Detector can…
To record a continuous 12-lead ECG, use a WT100C Wilson Terminal to create a virtual reference electrode when measuring the transverse plane (i.e., precordial) ECG components [V1, V2, V3, V4,…
This application note will explain how to update the MP unit firmware, install the AcqKnowledge software and make all necessary connections to acquire data when using one or more MP150s…
This application note will explain how to update the MP unit firmware, install the AcqKnowledge software and make all necessary connections to acquire data when using one or more MP150s…
This Application Note will explain how to update the MP unit firmware, install the AcqKnowledge software and make all necessary connections to acquire data when using one or more MP150s…
AcqKnowledge 3.7 runs with the MP100 or MP150 (high-speed) acquisition unit. USB and Ethernet options — view and control systems across a network, work outside your lab.
Stay Connected