BIOPAC® Systems, Inc. Logo

Biopac Student Lab Advanced Systems

The Gold Standard for Life Science Instruction

Advanced life science teaching solution

The preferred application for better science and greater discovery

BSL Advanced System - Win
Part #: BSLADV-W, BSLADV-M

BSL System with MP36 and hardware for 14 guided lessons plus 19 dynamic lessons and student-designed experiments. The ADVANCED System is extremely flexible and can be used across multiple disciplines including human physiology, pharmacology, psychophysiology, exercise physiology and a great many more. This system comes with everything you need (except the computer) to conduct the most widely studied responses in physiology labs, including experimental measurements of ECG, EEG, EMG, EOG, EDA, Pulse, Airflow, Respiratory Effort, Lung Volume, Reaction Time and Skin Temperature. The BSL Lab Manual and onscreen guides take you through each step, including initial setup, software options, and lesson procedures.

Teach the Way You Want

Create your own lessons, no programming. New Curriculum Management System.

Increase Student Engagement

Students record data from their own bodies, animals, or tissue preparations. +65 experiments.

Fast, Easy Set-Up & Operation

Reduces setup time by 90%. Guided lessons w/ on-screen instructions, video demos & sample data.

BSL Advanced Teaching System - Win
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Systems - Education
Subcategories: Advanced - Education

Alternatives
For the same Platform

Details

Compatibility


The BSL PRO software allows you to create your own lessons (no programming required), or use the system for advanced student projects and research.

The Biopac Student Lab Advanced System includes:
  • MP36 Data Acquisition Unit with USB Cable, DC Adapter (110V/60Hz or 220V/50Hz), and Power Cord (US or Euro)
  • BSL 4 Software (Lessons and PRO)
  • 2 x Electrode Lead Sets – SS2LB
  • Disposable Electrodes (100/pk) – EL503
  • Abrasive Pads (10/pk) – ELPAD
  • Airflow Transducer, factory-calibrated – SS11LB
  • Disposable Filtered Mouthpieces (10/pk) – AFT36
  • Disposable Noseclips (10/pk) – AFT3
  • Electrodermal Activity (EDA) Lead – SS57L
  • EDA/Isotonic Gel Electrodes (100/pk)- EL507
  • Pulse Plethysmograph Transducer – SS4LA
  • Respiratory Effort Transducer – SS5LB
  • Temperature Transducer – SS6L
  • Tape – TAPE1
  • Hand Switch – SS10L
  • Headphones – OUT1
  • Colored Paper Set (for BSL Lesson 9) – PAPER1
  • BSL Laboratory Manual MANBSL4
  • Install disk includes Searchable PDF Manuals and Tutorials (BSL PRO, Instructors Guide, Answer Key, etc.)

Perform 33 or more lessons with the Advanced System:

Muscular

  • BSL1 Standard & Integrated EMG
  • H07 EMG Contractions – Active Learning
  • H27 Facial EMG
  • H34 EGG Electrogastrogram (from Human)
  • H36 Muscular Biofeedback

Cardiovascular

  • BSL5 Components of the ECG (Lead II)
  • BSL6 Leads I, II, III & Einthoven’s Law
  • BSL7 ECG & Pulse
  • H05 WAnT Wingate Test
  • H08 Dive Reflex – Active Learning
  • H23 Signal Averaged ECG
  • H32 Heart Rate Variability

Pulmonary Function

  • BSL8 Respiratory Cycle
  • BSL12 Pulmonary Function: Vol. & Capacities
  • BSL13 Pulmonary Flow Rates: FEV and MVV
  • BSL15 Aerobic Exercise Physiology

Neurophysiology

  • BSL3 EEG Relaxation & Brain Rhythms
  • BSL4 Alpha Rhythms in the Occipital Lobe
  • BSL9 GSR and Polygraph
  • BSL10 Eye Movement, Saccades & Fixation
  • BSL11 Reaction Time & Learning
  • BSL14 Biofeedback: Relaxation & Arousal
  • H10 EEG & Hemispheric Asymmetry
  • H11 Mirror Test- EDA Sensory Motor Learning
  • H12 EOG Saccades & Displacement
  • H13 EOG Visual Tracking vs. Imagination
  • H14 Ocular Fixation while reading
  • H15 Ocular Fixation while viewing an image
  • H16 Reaction Time
  • H24 Habituation

Biomedical Engineering

  • H02 Compartmental Modeling
  • H20 BME Filtering
  • H33 FFT Fast Fourier Transform

Videos

Biopac Student Lab Teaching Systems

Biopac Student Lab Student Download

What's in the Box | BSL Starter Systems

Support

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
BIOPAC training

T4 Human Physiology Conference

Register Today! T4: Tools, Trends, Techniques, and Technology Monday, July 24, 2017 – Wednesday, July 26, 2017 Join BIOPAC for three days of hands-on, small-group human physiology workshops, presented by renowned experts, on the beautiful University of California at Santa Barbara campus in Santa Barbara, California, USA. Who should attend Anyone who records and analyzes […]

View All
Latest News

Mobita Advances Prestimulus EEG Research

The Mobita 32-Channel EEG recording system was used in research examining if physiological data can be used to predict truly random events that correspond to perceptual stimuli. Baumgart, et al. from the University of California Santa Barbara utilized a quantum random number generator (qRNG) to choose from three randomized conditions: light, sound, and no stimulus. […]

News Citations—Respiration and Cardiovascular Activity

BIOPAC provides software and hardware that allow for research teams to record and analyze respiration activity in physiological experimentation. Here are a few notable studies in monitoring respiration and cardiovascular activity. The coupling between peripheral microcirculation and slow breathing: The purpose of this study was to investigate the coupling of breathing movements and microcirculatory blood […]

Read All
Request a Demonstration
Request a Demonstration