Temperature Probes BIOPAC offers several temperature transducers that are suitable for surface and rectal or oral measurements. TSD202A-MRI for MP150 System + SKT100C + MECMRI-TRANS The TSD202A-MRI is a very small, fast response temperature…
Search
Use the DTU100 Digital Trigger Unit to trigger an MRI System with the occurrence of the R-wave present in ECG, respiratory data or blood pressure for gating purposes. This external hardware module…
Record up to 16 channels of sleep data. Review data in 15- or 30-second epochs for quick visual assessments. Use the Journal to indicate points of interest in the sleep record.…
Biopac Science Lab comes with two lessons focused on muscle activity: Lesson 1 — EMG I Electromyography: Motor Unit Recruitment Lesson 1 investigates the properties of skeletal muscle. Students record…
Record EMG to investigate the properties of skeletal muscle. Record and display raw and integrated EMG signals; overlap the signals for better correlation of the data. Measure strength and repeat…
Students can measure EMG and Integrated EMG, including force and angle of limb movement. Students can listen to the sound of the electrical activity coming from muscle as they squeeze…
Record surface EMG data to investigate the properties of skeletal muscle. Record and display raw and integrated EMG signals; overlap the signals for better correlation of the data. Measure strength…
Students can measure EMG and Integrated EMG, including force and angle of limb movement. They can listen to the sound of the electrical activity coming from the muscle as they…
Combine the human-safe stimulating electrode with the stimulator to record nerve conduction experiments. Stimulate the ulnar nerve and record nerve conduction time (see Lesson H03). This allows students to stimulate…
Combine the human-safe stimulating electrode with the stimulator to record nerve conduction experiments. Stimulate the ulnar nerve at three different points and record nerve conduction time. Measure the distance between…
Combine the human-safe stimulating electrode with the stimulator to record nerve conduction experiments. Stimulate the ulnar nerve at three different points and record nerve conduction time. Measure the distance between…
Stimulate and record signals from nerves in-vivo or in-vitro; using the built-in software averaging mode, it’s possible to record signals from in-vivo nerves using skin surface electrodes only. Surface electrodes…
Run 3rd-party applications in parallel with AcqKnowledge AcqKnowledge with Network Data Transfer has the capability to send all of its channels over the network to other computers as well as…
Nervous system functions such as sudomotor axon reflex, vasomotor, cardiac-vagal and adrenergic functions can be indicated with measurements such as beat-by-beat blood pressure, electrodermal response, skin temperature, ECG and respiration.
Study EEG under a variety of conditions to explore relaxation and brain rhythms, software will filter and display each rhythm separately: alpha, beta, delta, and theta. Select from a variety…
Study EEG under a variety of conditions to explore relaxation and brain rhythmsthe software can filter and display each rhythm separately: alpha, beta, delta, and theta. Study alpha rhythms in…
Study EEG under a variety of conditions to explore relaxation and brain rhythmssoftware will filter and display each rhythm separately: alpha, beta, delta, and theta. Select from a variety of…
Record high-fidelity noninvasive blood pressure with industry leading hardware for humans or small animals. MRI options are also available for both human and animal blood pressure recording. AcqKnowledge software includes…
The fNIR100 stand-alone functional brain imaging system for continuous NIR spectroscopy (NIRS) provides an in-lab cognitive function assessment. It eliminates a great many of the drawbacks of a functional MRI.…
Human—continuous system with finger sensor. Fits children through large adults. MRI system also available.
Complete Solutions for Nursing Programs Hands-on Physiology Lessons The Biopac Student Lab revolutionizes how students learn the life sciences by eliminating complex setup tasks and letting them focus on learning the subject. More than…
Use AcqKnowledge to turn LEDs on and off while recording EOG to study pendular or jerky nystagmus. The software can record both the slow and fast portion of nystagmus signal.…
fNIR optical brain imaging systems can be used to obtain objective response assessment instead of relying on subjective responses from a participant. fNIR measures neural activity and hemodynamic response in…
During normal viewing conditions, a subject makes 3-5 saccades per second, separated by periods (fixations) of 200-300 ms where the eyes do not make large or fast movements. To isolate saccade-to-saccade…
Use off-line ECG Averaging to quickly isolate changes in the ECG complex. Display the averaged ECG complex before, during and after dosing or exercising. Select an area and AcqKnowledge® will…
Utilize the powerful online analysis capabilities of the AcqKnowledge software for chronic, acute and in-vitro preparations in both long- and short-term experiments. Sophisticated algorithms will record and analyze, online, a variety…
The AcqKnowledge Rate detector has automated tools for deriving heart rate (HR) and inter-beat-interval (IBI) on a cycle-by-cycle basis. The Rate detector operates in both real-time and off-line modes. The…
Blood pressure varies based on the subject’s physical orientation in a gravitational field. The NIBP100D can be attached to a subject placed on a tilt table. Use TSD109 accelerometers to determine…
When used in conjunction with an occluding cuff, electrical bioimpedance measurements on limbs can assess arterial blood flow and venous thrombosis. To prevent venous outflow without significantly changing arterial inflow, rapidly…
Peristaltic electrical signal propagation can be recorded using monopolar or bipolar recording techniques with the EGG100C and AcqKnowledge. To derive either long or short distance bipolar data, configure the amplifier to…
The Biopac Student Lab Pharmacology and Toxicology Core Discipline package combines a range of experiment options for cardiovascular hemodynamics, respiratory system, pulmonary function, in vitro tissue and cellular studies. The new…
Implement simple experiments illustrating physiological control systems with the BSL System. Students can observe signal changes and then effect a change to observe a particular response. Investigate linear and nonlinear…
Flaps and planted tissues typically exhibit changes in blood flow after the planting procedure. The MP System can be programmed to control a visual or auditory alarm if the mean or…
Record PPG, measure BP indirectly, look at appendage size variations, and perform sexual arousal studies using BIOPAC or 3rd-party transducers.
Record and Analyze Pressure-Volume Loop Data! Flexible graphing capabilities let users display data in a variety of formats (Chart, Scope or X/Y); simple toolbar icons make it easy to switch between display…
AcqKnowledge will extract beat-by-beat systolic, diastolic and mean blood pressure data from the raw blood pressure waveform. Simultaneously, data can be collected from ECG, EOG, EMG, RSP, EDA (GSR) and SKT amplifiers.…
Record and analyze BP, ECG, HRV, EDA, EMG, EEG, EOG, RSP, etc. Interface to stimulus presentation programs...use automated analysis routines to easily score and analyze data.
The Biopac Student Lab Psychophysiology and Neurophysiology Core Discipline package presents a wide array of psychophysiology experimental techniques as lessons guide students through recording and analysis modalities to provide building blocks…
The Pulmonary Air Flow analysis is part of a suite of three automated respiration routines that are included in AcqKnowledge®. The other two are Compliance and Resistance and Full Body…
Automatically analyze pulsatile tissue data with the online calculation channels. The calculations will provide real-time values for maximum, minimum, peak-to-peak and the area under the curve for each response. To…
The NICO100C easily measures the change in thoracic impedance that occurs as the heart beats. As blood is forced out of the aorta during ventricular ejection, the impedance through the torso…
Pulse Transit Time (PTT) is the time it takes the Pulse Pressure (PP) waveform to propagate through a length of the arterial tree. The pulse pressure waveform results from the…
Use AcqKnowledge® to determine the velocity of motion occurring during physical activity. All parts of the body can be evaluated for range of motion. Goniometers are available for evaluating one or…
Record single- or multi-channel montages with on-line calculation channels for Delta, Theta, Alpha, and Beta wave activity. On-line calculation channels allow the display of raw and filtered data in real time,…
Deglutition means the act or process of swallowing. There are many ways to record swallowing/deglutition. Using a pressure pad delivers high quality data and is much simpler than standard approaches…
To analyze regional blood flow, occlude the venous return with the blood pressure cuff (TSD120) and measure the swelling of the distal portion of the limb with a mercury strain…
Simplified view of subject data on another computer or mobile device. Remote Monitoring provides a simple browser interface, from which acquisitions can be started, stopped and remote data viewed during…
BioNomadix modules provide high quality, full-bandwidth data for a variety of signals—ECG, EEG, EGG, EMG, EOG, PPG, RSP, SKT, Accelerometry, Cardiac Output, Dynamometry, and Heel-Toe Strike.
Perform lung volume measurements, examine pressure/volume relationships, and analyze respiratory gases. Use AcqKnowledge to integrate airflow and analyze data.
For bioimpedances measured across the thorax using the EBI100C, a small impedance change is observed with each inspiration and expiration. For respiration monitoring, electrodes are placed across the mid-thorax along…
Stay Connected