Nerve Conduction Studies

AcqKnowledge nerve conduction data

Stimulate and record signals from nerves in-vivo or in-vitro; using the built-in software averaging mode, it’s possible to record signals from in-vivo nerves using skin surface electrodes only. Surface electrodes can also be used for peripheral nerve stimulation (PNS) and to evaluate the effects of stimulation to motor nerve endings in terms of electrical or mechanical response. Configure stimulation sources to provide electrical, somatosensory or visual stimulation, and vary the duration and level of stimulus. In addition to the stimulator, up to 16 amplifiers can be simultaneously employed to record nerve and/or muscle responses. The system software permits easy determination of peak times and maximum responses for a variety of nerve conduction studies (NCS) and nerve conduction velocity tests (NCV).

Use the AcqKnowledge® stacked plot mode to overlap both the stimulus waveform and the response. The software allows you to advance through each of the responses and the software highlights the response and specific stimulus waveform to make it easier to determine which response relates to each stimulus waveform.

Details

This is one of many ADVANCED FEATURES for the selected Application. Scroll down for hardware options.

Support

Application Notes

Knowledge Base

Spotlight On

ECG Electrocardiogram Amplifier for MRI

The ECG100C-MRI Electrocardiogram Amplifier records electrical activity generated by the heart and will reliably record ECG from humans, animals and isolated organ preparations. The amplifier output can be switched between normal ECG output and R-wave detection. The R-wave mode outputs a smoothed pulse with the occurrence of each R-wave. The exact timing of the R-wave […]

View All
Latest News

New Citations | BIOPAC in HRV Analysis Research

BIOPAC provides researchers with a complete range of tools to gather data on heart rate variability (HRV). The following studies demonstrate just some of the ways in which HRV research benefits from the implementation of BIOPAC hardware and software solutions. PTSD and HRV Post-traumatic stress disorder (PTSD) has been associated with dysfunction of the autonomic […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration