All Products Applications Curriculum Knowledge Base Videos News Content
Electrodermal Activity (EDA) Scoring [Advanced Feature]

Record and analyze EDA/GSR data wirelessly with BioNomadix or with standard wired amplifiers. AcqKnowledge includes a fully automated scoring system for electrodermal activity (EDA) data. The feature includes options for…

EMG & Force [Advanced Feature]

For in-depth studies of muscle work and fatigue, use the EMG100C amplifier with a hand dynamometer (TSD121C). The software will display the force measurements (calibrated in pounds or kilograms) as well…

EMG and Movement Analysis [Advanced Feature]

AcqKnowledge includes tools to set limits and thresholds to isolate specific events within data files from surface EMG (sEMG) and movement (e.g., accelerometry or goniometry) recordings to identify when a subject…

EMG Power Spectrum Analysis [Advanced Feature]

A common tool for investigating electromyography (EMG) data is the Power Spectrum Density (PSD). Use AcqKnowledge for EMG Frequency & Power Analysis to compare responses from one part of the…

EMG: Electromyography [Application]

Record surface, needle, and fine wire EMG—or wireless EMG with BioNomadix. Use real-time integration tools for immediate analysis or use automated EMG analysis routines.

End-Tidal CO2 (ETCO2) [Advanced Feature]

To measure end-tidal CO2 on a breath-by-breath basis, use the AFT20 gas sampling interface kit to connect the CO2100C module directly to the sampling port on the AFT25 facemask. Use AcqKnowledge’s…

Ensemble Averaging [Advanced Feature]

AcqKnowledge includes an ensemble average analysis feature to average user-selected areas of a data file, such as baseline, recovery, or intervals of cleaner data. Extremely useful for impedance cardiography and ECG signal…

EOG – Psychophys. [Area of Study]

Students can record horizontal and vertical eye movements while observing fixation and tracking. The X/Y display mode will plot horizontal vs. vertical eye movement to track eye position relative to…

EOG: Eye Movement [Application]

Record eye position and movement with the EOG100C amplifier. Find frequency, distance, velocity, and point of focus. Isolate behavior associated with nystagmus and saccades.

Ergonomics Evaluation [Advanced Feature]

Body position and posture can be analyzed over a wide range of static and dynamic conditions and these measurements can be used to determine the ergonomic characteristics of a specific…

ERS: Evoked Response [Application]

Record evoked, late, and field potentials, as well as startle and nerve conduction. Powerful on- and off-line averaging features (P300), and dual stimulation ability with the MP150.

Event Related Potentials – Psychophys. [Area of Study]

Combine the BSL with a visual presentation system such as SuperLab to explore a wide variety of experiments such as the Stroop test, oddball paradigm, habituation, and startle response. SuperLab…

Event-Related EDA Analysis [Advanced Feature]

AcqKnowledge® includes a fully-automated suite of tools for Event Related Electrodermal Activity applications. The analysis is based around the timing marks that come from stimulus presentation systems (Superlab®, E-Prime®, DirectRT®,…

Event-Related Potentials (ERP) Analysis [Advanced Feature]

Present a variety of visual and auditory stimuli on one computer while AcqKnowledge records the stimuli event markers and psychological responses on another computer. As the stimuli are presented, the STP100W…

Evoked Response [Advanced Feature]

Powerful on- and off-line averaging features make it possible to perform a wide variety of evoked response studies. Record and measure evoked potentials, late potentials, startle, nerve conduction and field potentials.…

Evoked Response – Psychophys. [Area of Study]

Lessons guide students through evoked response recordings. Use the system to trigger a stimulus and derive the average response. Use with auditory (i.e. headphones), visual (i.e. stroboscope), or somatosensory (i.e.…

Evoked Responses [Advanced Feature]

Record and analyze auditory, visual and somatosensory evoked responses. The on-line averaging function allows the user to perform detailed evoked response studies. Average physiological evoked responses in synchronization with stimulus presentation.…

Exercise Physiology [Advanced Feature]

The TEL100C works efficiently with subjects performing anaerobic exercises because it eliminates the masses of cabling usually attached to the subject. The TEL100C module will record a wide variety of signals…

Exercise Physiology [Application]

Examine ventilation, oxygen uptake, carbon dioxide production, biopotentials, temp., and biomechanical signals simultaneously. Record wirelessly with BioNomadix.

Exercise Physiology and Biomechanics [Discipline]

The Biopac Student Lab Exercise Physiology and Biomechanics Core Discipline package makes it simple to combine a wide range of respiratory system and pulmonary function signals with biomechanical data. Use…

Exercise Physiology and Biomechanics – Human [Area of Study]

Combine a wide range of Respiratory System & Pulmonary Function signals with biomechanical data. Use the new Gas Analysis System for online analysis of expired O2 and CO2  levels. Options…

Extra-cellular Spike Recording [Advanced Feature]

Record and analyze extra-cellular spikes using a glass or wire micro-electrode and the MCE100C micro-electrode amplifier. Use the averaging function in AcqKnowledge to determine the average response, or count the number…

Eye Tracking [Advanced Feature]

Add Eye Tracking to gather meaningful insights on attention and decision making. BIOPAC offers an array of eye tracking systems that are easily integrated with a VR system. VIRTUAL REALITY…

Eye Tracking [Application]

Precision eye tracking & synchronized biometrics Neuroscience research teams, scientific researchers, and commercial consumer marketers can now easily record and analyze precise eye tracking data and physiological data with hardware/software packages from…

Eye Travel and Position [Advanced Feature]

Determine a participant’s visual path when first exposed to a sign, advertisement, or new ergonomic layout. The X/Y display mode will track a subjects eye travel and display the exact pattern…

Facial EMG & Startle Response [Advanced Feature]

Facial electromyography (fEMG) typically uses surface EMG electrodes to detect activity at the zygomaticus (cheek), orbicularis oculi (under eye), and/or corrugator supercilii (brow) muscle regions as a participant is exposed…

Field Potential Measurements [Advanced Feature]

To perform field potential measurements, position electrodes around the isolated tissue or organ and use the MCE100C to record the potential. Each MCE100C can record a single differential potential. Multiple MCE100C…

Filter Multiple Channels at Once [Advanced Feature]

Filter Multiple Channels at Once allows FIR, IIR, or Comb Band Stop filters to be selectively applied to a single EEG channel or to multiple EEG channels at the same…

Filtering [Advanced Feature]

Filtering is a core signal processing function. Filtering is the act of discrimination between one type of data and another. In the case of physiological signal processing, filters are employed…

fNIR for Muscle Oxygenation [Advanced Feature]

Record microvascular oxygenation during muscle activation Sample Data download → fNIR_EMG.zip (extract biceps_EMG_fnir_demo.acq) Using functional Near Infrared (fNIR) to study muscle function can provide greater understanding of the underlying control mechanisms that couple…

fNIRS for Education [Advanced Feature]

NIRS brings real-time imaging to the lab without the drawbacks of the functional MRI or other imaging techniques that are expensive, time-consuming, and complex. In contrast, NIRS technology is affordable,…

Forced Expiratory Flow and Volume [Advanced Feature]

Measure the average flow over specified portions of the spirometry curve. The spirometry maneuver requires the subject to inhale to total lung capacity and then exhale forcefully to residual volume.…

Full Body Plethysmograph Penh [Advanced Feature]

The AcqKnowledge® Full Body Plethysmograph – Penh analysis is part of a suite of three automated respiration routines. The other two are Compliance and Resistance and Pulmonary Air Flow. Each routine…

Gait Analysis [Advanced Feature]

Simultaneously acquire up to 16 channels of gait-specific data, including heel-toe, goniometry, accelerometry and more. One setup might incorporate two channels for heel/toe strike timing, ten channels for EMG signals and…

Gas Analysis – Animal [Area of Study]

Use the new gas analysis system for detailed metabolic studies in small and medium sized animals. Chambers, couplers, facemasks, and tubing options provide setup options for any protocol. The system…

Gas Analysis – Biology [Area of Study]

Students can use the new gas analysis system to monitor expired CO2 and O2 levels for detailed metabolic studies with human and animal subjects. Take measures to study ventilation and…

Gas Analysis – Exercise [Area of Study]

Use the new gas analysis system to create a powerful metabolic analyzer (cart) for students to measure expired O2 and CO2 and with lessons for VO2, Respiratory Exchange Ratio, and…

Gastric Myoelectric Activity [Advanced Feature]

The normal stomach generates a myoelectric signal (EGG) that oscillates with a period of three cycles per minute. The EGG can be measured noninvasively by using the EGG100C amplifier and standard…

Gastric Slow Wave Propagation [Advanced Feature]

The gastric slow wave (ECA) originates in the proximal stomach and propagates distally towards the pylorus. For recording, place multiple surface electrodes on the abdomen along the gastric axis and connect…

Gastrointestinal Motility Analysis [Advanced Feature]

The ECA (slow wave) and ERA (electrical response activity) components of the electrogastrogram (EGG) can be isolated using the digital filters in AcqKnowledge. To isolate the ECA component, apply a…

General Micro-Electrode Signal Amplification [Advanced Feature]

The MCE100C micro-electrode amplifier is designed to work with a wide range of micro-electrodes in a variety of measurement applications. To record biopotentials, use standard reusable or disposable Ag-AgCl electrodes…

H-Reflex Methodology [Advanced Feature]

The Hoffmann reflex (H-reflex) is an electrically induced reflex that bypasses the muscle spindle. H-reflex is a useful measure to assess modulation of monosynaptic reflex activity in the spinal cord.…

Hardware API option – BME [Area of Study]

Use the hardware application program interface (BHAPI) to create your own programs to control BIOPAC's MP36/35 or MP150 hardware.  

Hardware Flexibility [Advanced Feature]

Use the MCEKITC to interface a variety of micro-electrode cables to the MCE100C amplifier. For your pre-existing setup, choose an appropriate Analog Connection Cable to connect your microelectrode amplifier to the…

Heart [Area of Study]

Biopac Science Lab comes with three lessons focused on heart activity: Lesson 3 — ECG I Electrocardiography: Components of the ECG Lesson 3 introduces the electrocardiograph (ECG) and the recording…

Heart Rate Variability (HRV) Analysis Software [Advanced Feature]

AcqKnowledge® includes a series of automated Heart Rate Variability (HRV) analysis tools that conform to international cardiology standards. It is possible to perform the analysis over user defined selections of…

Heart Sounds [Advanced Feature]

Record the sounds associated with valve openings and closings and with the flow of blood within the heart during the cardiac cycle. Place a TSD108 Physiological Sounds Microphone on the anterior…

Histogram Analysis [Advanced Feature]

Use the Histogram display features to identify trends within the EMG data. Select an area of data, or the entire data file, and the Histogram feature will bin the values…

Human and Animal Physiology – BME [Area of Study]

The wide range of human and animal physiology experiments provide a powerful tool for teaching students the best technique and methodology for making a measurement or performing a therapy. Each…