Gas Analysis – Animal

Use the new gas analysis system for detailed metabolic studies in small and medium sized animals. Chambers, couplers, facemasks, and tubing options provide setup options for any protocol. The system can provide online measures of O2 and CO2 for RER, VO2 and BMR/RMR. Use the dissolved O2 probe and lesson to measure the oxygen consumption of a goldfish.

Hardware

Name Description Cart
Disposable Bacterial Filters Disposable bacteriological filters for use with 22 mm breathing circuits, such as BIOPAC pneumotach transducers SS11LA, TSD117, or SS11. These filters remove airborne bacteria. Pore size—VFE: 3.1 micron; BFE: 2.8 micron MRI Use: MR Safe (see Specifications for components)

$51.00 - $795.00Select options This product has multiple variants. The options may be chosen on the product page

Disposable Mouthpiece These mouthpieces connect to the TSD117 pneumotach transducer and other 22 mm breathing circuits. Connects directly to the AFT1 bacterial filter, AFT22 non-rebreathing T valve (via AFT11C) and the TSD117 air flow transducer. (Pkg. 10 or 250) MRI Use: MR Safe (see Specifications for components)

$18.00 - $195.00Select options This product has multiple variants. The options may be chosen on the product page

Disposable Noseclip These nose clips gently squeeze the nostrils shut to prevent errors when using mouth-breathing circuits. Available in packs of 10 or 250. MRI Use: MR Safe (see Specifications for components)

$20.00 - $260.00Select options This product has multiple variants. The options may be chosen on the product page

Cal. Syringe, 600 ml Medium pump syringe used for injecting a precise volume of air (600 ml) through airflow assemblies for precise calibration. The AFT6A fits (ridged) 27 mm OD, 30 mm OD, and 15 mm ID. Fits directly to AFT13 (30 mm) filter and mouthpiece AFT23 (27 mm) non-rebreathing T-valve with replacement valves Use coupler AFT11A to connect…

$212.00Add to cart

Cal. Syringe, 3 liter The AFT27 3.0 Liter Calibration Syringe is certified to have a volume that meets or exceeds an accuracy of 0.5% of the total displacement volume (3 liters ±0.5%). This adjustable aluminum calibration syringe is shipped with the volume locked to 3.0 L and BIOPAC templates and software settings are set for 3 L.  The locking collar and…

$460.00Add to cart

Airflow Transducer The SS11LB handheld airflow transducer is intended for human use and can be used to perform a variety of tests relating to airflow and lung volume. The transducer is factory-calibrated to measure airflows within -10 to +10 L/second within ±5%. The transducer has a removable head (RX117A) for sterilization and replacement. No calibration syringe is required.…

$555.00Select options This product has multiple variants. The options may be chosen on the product page

Pneumotach Transducer 50 ml/sec Airflow Heated The SS46L pneumotach can perform a variety of pulmonary measurements relating to airflow, lung volume, and expired gas analysis. Each transducer type consists of an airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137B1 with SS40L). The pneumotach will connect directly to a breathing circuit or plethysmogram chamber. For airflow and…

$0.00Add to cart

Heated Airflow Transducer 83 ml/sec The SS47L is a heated pneumotach suitable for a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis. The transducer consists of an airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137C1 and SS40L). The pneumotach will connect directly to a breathing circuit or plethysmogram chamber. For airflow and…

Login for pricingAdd to cart

Pneumotach Heated Airflow Transducer 166 ml/sec The SS48L heated pneumotach can perform a variety of pulmonary measurements relating to lung volume, airflow, and expired gas analysis. Each pneumotach transducer consists of an airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137D1 to SS40L) and is equipped with an internal heating element and 6-volt power supply AC137A. The pneumotachs…

Login for pricingAdd to cart

Heated Pneumotach Transducer 583 ml/sec The SS49L heated pneumotach can perform a variety of pulmonary measurements relating to expired gas analysis, airflow, and lung volume. Each transducer type consists of an airflow pneumotach head coupled to a precision, highly sensitive, differential pressure transducer (RX137E1 with SS40L). The pneumotachs will connect directly to a breathing circuit or plethysmogram chamber. For airflow…

Login for pricingAdd to cart

Dissolved O2 Probe Transducer – MP3X/46/45 The SS69LA transducer measures dissolved oxygen. This easy-to-use dissolved O2 probe relies on fluorescence and has temperature and pressure sensors, allowing it to provide calibrated output with no need for two-point calibration. The cable box contains an SD card which holds calibration information and a switch allowing transducer output to be proportional either to % oxygen…

$960.00Add to cart

WHAT'S NEW

New Citations | BIOPAC in EEG Studies

Electroencephalography (EEG) is a highly versatile signal in physiology research Researchers are...

Join the BIOPAC Community

Stay Current

Stay Connected

Request a Demonstration
Request a Demonstration