EPOCH wireless in vivo recording

EPOCH wireless in vivo recording systems are a low-cost solution for continuous, long-term biopotential recordings from rodents…EEG (2, 4, or 6 channel), ECoG, ECG, EMG. EPOCH wireless transmitters are available for a variety of signals with 2 week, 2 month or 6 month battery life, with new reusable and differential transmitter options. This overview details the components of EPOCH wireless in vivo recording systems. When paired with BIOPAC’s MP Research System & AcqKnowledge, automation and scoring tools can identify seizures, predefine and control recording protocols, set triggers based on external events, quickly score multiple channels of EEG data simultaneously, derive frequency bands, complete a frequency analysis, look at Alpha RMS, and more. Click to learn more about the EPOCH advantage.

EPOCH wireless in vivo recording – EEG monitoring

epoch-implant-jovehttp://www.jove.com/video/52554/long-term-continuous-eeg-monitoring-small-rodent-models-human-disease

This video describes the technology behind EPOCH transmitters and demonstrates the use of  this novel miniature telemetry system, specifically engineered for use in immature rats or mice, which is also effective for use in adult animals in pre-clinical research with continuous EEG in young animal models of seizures and other neurological disorders.

Eye Tracking & Physiology – Synchronized Data

Multimedia functionality in AcqKnowledge software gives users complete control to see how particular tasks impact the physiological response: physiology file advances video or video moves to precise point in the physiological record…or just play the entire recording. Left side shows data downloaded from a Wireless BioNomadix  Logger & Physiology data transmitters placed on subject: on-board accelerometer (x, y, z); Heart (ECG); Pulse; Respiration; Electrodermal activity. Right side shows video recorded from SMI Eye Tracking Glasses as the subject was wearing them and performing tasks while fully mobile. Playback shows video of precisely what the subject is looking at as performing a task and you see the cursor move forward in the data file, synchronized to the precise point in the video. Green dot shows focus point of subject (driver in this case), so at any given moment in time you know precisely were driver is looking. Learn more about Eye Tracking glasses and wireless BioNomadix Logger & Transmitters.

Eye Tracking Use Case | ETVision + StimTrac Dynamic Overlay

This video shows ETVision wearable eye tracking running a game application on a laptop and recording screen content for dynamic overlay. StimTrac (Stimulus Tracking Module) is used to transfer the data from the scene camera coordinate frame to the stimulus coordinate frame. StimTrac adds exciting new data analysis technology for eye tracking mobile devices and computers! BIOPAC Part #: EYE-ETV-STIM StimTrac Module ETAnalysis Licensed Feature Add-on for Existing Argus Eye Tracking Glasses Users

Eye Tracking Use Case | ETVision + StimTrac on iPhone

This video shows ETVision wearable eye tracking running a game application on an iPhone. StimTrac (Stimulus Tracking Module) is used to transfer the data from the scene camera coordinate frame to the phone and track the position of the phone for gaze analysis. StimTrac adds exciting new data analysis technology for eye tracking mobile devices and computers! BIOPAC Part #: EYE-ETV-STIM StimTrac Module ETAnalysis Licensed Feature Add-on for Existing Argus Eye Tracking Glasses Users

Eye Tracking Use Case | ETVision + StimTrac on Laptop

This video shows ETVision wearable eye tracking running a game application on a laptop. StimTrac (Stimulus Tracking Module) is used to transfer the data from the scene camera coordinate frame to the stimulus coordinate frame. StimTrac adds exciting new data analysis technology for eye tracking mobile devices and computers! BIOPAC Part #: EYE-ETV-STIM StimTrac Module ETAnalysis Licensed Feature Add-on for Existing Argus Eye Tracking Glasses Users

Eye Tracking Use Case | ETVision + StimTrac on Two Monitors

This video shows ETVision wearable eye tracking used with two monitors in portrait mode. StimTrac (Stimulus Tracking Module) is used to transfer the data from the scene camera coordinate frame to the phone and track the position of the phone for gaze analysis. StimTrac adds exciting new data analysis technology for eye tracking mobile devices and computers! BIOPAC Part #: EYE-ETV-STIM StimTrac Module ETAnalysis Licensed Feature Add-on for Existing Argus Eye Tracking Glasses Users

Eye Tracking Webinar | BIOPAC & SMI

BIOPAC and SensoMotoric Instruments experts present user case studies to demonstrate new research capabilities made possible by the plug & play integration of SMI eye tracking technology with BIOPAC’s wireless physiological recording systems.

Eye Tracking with Synchronized Physiology Data

Synchronize eye tracking data & video with physiological data. Wearable, lightweight ETVision eye tracking glasses contain miniature “eye cameras” that view each eye and a “scene camera” that views the scene in front of the participant, plus a microphone. Precise, binocular point of gaze at frame rate 180 Hz. Easily synchronize with BIOPAC’s AcqKnowledge research software to include multiple physiological measures for a comprehensive research study. Just click on a point of interest in the eye tracking playback or the physiology data and the synchronized files will adjust to that moment. Learn more at EYE-ETV.

FaceReader – Contempt classifier

FaceReader now automatically classifies contempt (in v6 or above). Contempt is defined as the feeling that a person or a thing is beneath consideration, worthless, or deserving scorn and therefore seen as a negative emotion. Add depth to your study by measuring contempt in addition to other facial expressions. FaceReader is available as software, but also as an online application. Integrate with physiology data in AcqKnowledege through Licensed Feature FR-INTERFACE.

FaceReader Affective Attitudes

See the real-time capability of the FaceReader Action Unit Module to measure three commonly used affective attitudes: boredom, confusion, and interest. They are not completely expressed within a single instance, but computed over a window of time. In addition, some of these affective attitudes also take into account certain additional facial cues, such as nodding or head shaking.

FaceReader Classifications Demo

FaceReader™ is the premier professional software for automatic analysis of facial expressions. FaceReader provides objectivity when studying the effects of different stimuli. FaceReader automatically analyzes 6 basic facial expressions- neutral, contempt, and boredom, interest, and confusion-and also calculate gaze direction, head orientation, and person characteristics. Accurate modeling of the face is achieved from descriptions of 500 key points and more than 10,000 manually-annotated images used for training the software. FACEREADER

FaceReader Facial Expression Classifier

FaceReader is the premier professional software for automatic analysis of six basic facial expressions (happy, sad, scared, disgusted, surprised, and angry), as well as classifying neutral and now contempt. FaceReader also provides gaze direction, head orientation, and person characteristics, such as gender and age. Detailed analysis of facial action units is also available. The software immediately analyzes your data (live, video, or still images), saving valuable time. Integrate with physiology data in AcqKnowledege through Licensed Feature FR-INTERFACE.

Network Data Transfer demo using heart rate to change hand

An example of using BIOPAC’s Network Data Transfer protocol to send physiological data from AcqKnowledge to other applications in real time.

NIBP Webinar | Integrating Noninvasive Blood Pressure Monitoring with Human Physiology Measurements

In this webinar sponsored by BIOPAC Systems and CNSystems, Frazer Findlay and Walter Habenbacher discuss study design and demonstrate correct equipment set up and operation when recording NIBP with additional physiological signals. Specifically, Mr. Habenbacher explains the application of the NIBP100D-HD to measure noninvasive continuous blood pressure. He demonstrates setup & measurement and shows how scientific findings can benefit your research with advanced hemodynamic monitoring.

Following, Mr. Findlay demonstrates how to interface the NIBP100D Continuous Noninvasive Blood Pressure Monitor with the BIOPAC MP160 Data Acquisition and Analysis System and simultaneously recorded measurements of NIBP, ECG and respiration.  In addition, Mr. Findlay discusses important data analysis processes such as computing cardiac output and stroke volume, and demonstrates how scientists can use the “Focus Areas” feature in AcqKnowledge Software to simplify their data review.

Noldus The Observer XT Import/Export in AcqKnowledge

Use simple menu options for export to and import from Noldus The Observer XT v11 and AcqKnowledge 4.3 or above. Easily export AcqKnowledge event marker label and time to The Observer XT—select all events or limit by type, such as stim/response events. Import The Observer XT ‘point’ and ‘state’ behaviors as AcqKnowledge events. Import ‘state’ start, stop, label, and duration and/or import ‘point” label and time. Imported event details are marked in the AcqKnowledge event region and included in the event palette for complete analysis and reporting options. Using AcqKnowledge with Noldus The Observer XT Data

SMI BeGaze Import and Synchronization

You can synchronize and merge SMI BeGaze eye tracking data with BIOPAC physiological data. Using the merged data, it’s easy to explore the relationship between a stimulus presentation and the physiological response that follows. To merge data, use the Eye Tracking Import Licensed Feature key (ACK100W-ETG ). Connect the SMI parallel port to BIOPAC isolated digital interface STP100D, then set SMI experiment center to send a trigger with each stimulus presentation, and set AcqKnowledge to record the triggers on a digital channel. When SMI data is imported and merged with an AcqKnowledge file, the trigger data is used to precisely align the data.

VR | Unity VR Interface for AcqKnowledge

Immerse your users and capture biofeedback for analysis! Use Unity® Interface for AcqKnowledge®  (UNITY-INTERFACE ) to easily connect Unity3D projects with BIOPAC acquisition hardware and analysis software. Create virtual environments using industry-standard Unity, connect and configure projects with AcqKnowledge in real time; control acquisition from Unity to Custom Markers, Digital, and Analog I/O; deploy to your devices. Find additional samples at VR Resources.