Voltage Stimulators

The Gold Standard for Life Science Instruction

Stimulation for Biopac Student Lab®

Request More Info
Voltage Stimulator for BSL MP36/35
Part #: BSLSTMB, BSLSTMA

The Voltage Stimulator connects to either the MP36/MP35 or the MP30. BNC output provides compatibility with a variety of stimulator cables. The voltage Range and Level are manually controlled while the pulse timing is user-adjustable and controlled by the Biopac Student Lab software.

The Voltage Range (.025-10 Volts or .12-100 Volts) is established by a switch with a removable key. The Level is set using the knob and digital readout on the front panel. The Reference Output cable connects to any of the MP input channels for simultaneous recording of the stimulator output. A switch on the front panel allows the Reference pulse width to be “Fixed (15 ms)” so it can be recorded even when the sample rate is lower than the output pulse width.

See More...

MP356/35 Voltage Stimulator 100V
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Stimulation - Education
Subcategories: Stimulators - Education

Alternatives
For the same Platform

Details

Compatibility


A control panel in the BSL PRO software allows for precise control of the number of pulses (select 1-254 or continuous), pulse width and pulse repetition (frequency). Pulse width and repetition can be changed “on the fly.” The stimulator can be set to start with the recording or manually at any time. Parameter limits can be established and Event markers can be activated to indicate when a change in pulse output occurs.

The stimulator can be used for the following physiological measurement protocols:

  • Twitch sub-threshold
  • Twitch threshold
  • Maximum twitch responses
  • Single twitch, summation
  • Tetanic contraction
  • Muscle tension/length versus force
  • Fatigue
  • Nerve conduction velocity

Stimulation electrodes:

  • HSTM01 Human-safe Handheld Stimulation Electrode
  • ELSTM2 Needle Electrode

Stimulation cables:

  • Nerve chamber cables: BSLCBL1A, BSLCBL2A, BSLCBL3A, and BSLCBL4B
  • Clip cables: BSLCBL7, BSLCBL11, and BSLCBL12
WARNING
Like all stimulating devices, the BSLSTM stimulator can be dangerous–please follow all stimulation safety guidelines!
  1. When powering ON the BSLSTM stimulator and/or the MP36/35 unit, follow this procedure for maximum safety: Connect the Trigger and Reference Output cables from the BSLSTM to the MP36/35 unit.
  2. Turn the MP36/35 unit ON.
  3. Launch the BSL PRO Software.
  4. Click on the MP36/35 menu and select Output Control>Stimulator.
  5. Turn the Level knob on the BSLSTM to 0 volts (fully counter-clockwise).
  6. Flip the BSLSTM Power switch ON.
  7. Attach the Output from yhe BSLSTM to the subject.
  8. Turn the Level knob to the desired initial output level.
  9. Click on the “START” button in the BSL PRO software to start acquiring data — Preferences may be set to start stimulation with start of acquisition or with the switch in the Stimulator output Control window.
  10. Incrementally adjust the Level for the desired Output.
  11. When you have completed recording and taken the required measurements, turn the Level back to 0 volts.

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
free BIOPAC webinar

Good, Better, Best: Options for Subject Prep

The best ways to set up participants to record good data for life science research and teaching labs.
– Which electrode?
– Which lead?
– Do I need Ground (GND)?
– Best placement?
– Best recording system?

We’re turning on the web cam and showing you LIVE how to best prep participants for a variety of life science signals and measurements.

Join us! Live webinar – Oct 29

Register Now
Latest News

New Citations | Neuroscience Studies with BIOPAC

Effects of MDMA on attention to positive social cues for behavioral disorders The psychostimulant drug 3,4-methylenedioxymethamphetamine (MDMA) reportedly produces distinctive feelings of empathy, closeness with others and increased social behavior. Researchers are exploring the potential of this chemical for treatment of psychiatric disorders, such as autism spectrum disorder (ASD) and post-traumatic stress disorder (PTSD). This […]

Electrocardiography Guide Now Available

BIOPAC’s just released Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines […]

Read All
Request a Demonstration
Request a Demonstration