BIOPAC® Systems, Inc. Logo

Autonomic Nervous System – Psychophys.

Use the BSL system to record changes in the parasympathetic and sympathetic nervous system. Acquire a wide variety of ANS signals such as EDA/GSR, skin temperature, ECG, pulse, respiration, airflow, nerve conduction, continuous blood pressure, and continuous noninvasive cardiac output (bioimpedance method). Simultaneous graphing shows heart rate, electrodermal activity (GSR) and respiration rates. After the experiment, evaluate the data using the powerful and user-friendly analysis functions and automated scoring routines.

Hardware

Name Description Cart
General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$40.00 - $295.00 Select options

Bioimpedance Strip Electrodes Use as an alternative to band electrodes This unique disposable strip electrode is designed for bioimpedance applications. The electrode is sticky hydrogel with carbon film backing and industry-standard medical grade adhesive, medium tackiness. The silver-silver chloride (Ag/AgCl) electrode provides accurate and clear transmission of surface biopotentials and is latex free. Advantages of the Strip Electrode…

Read more

EDA Electrodes These disposable snap electrodes are designed for electrodermal activity studies and are pre-gelled with isotonic gel. The latex-free electrodes conform and adhere well to fingers. Use with LEAD110A or SS57L unshielded electrode lead. Standard snap connection Ag/AgCl contact Electrolyte: wet liquid gel (0.5% chloride salt) Incorporates gel cavity Strong adhesion Size: 27 mm wide x 36 mm…

$48.00 - $369.00 Select options

Voltage Stimulators The Voltage Stimulator connects to either the MP36/MP35 or the MP30. BNC output provides compatibility with a variety of stimulator cables. The voltage Range and Level are manually controlled while the pulse timing is user-adjustable and controlled by the Biopac Student Lab software. The Voltage Range (.025-10 Volts or .12-100 Volts) is established by a switch with…

Login for pricing Select options

Electrode Gels Use this non-irritating, hypo-allergenic gel as conductant with electrodes. Click to review MSDS. MRI Use: Conditional Condition: Max MR field strength 7T. (See Specifications for components.) See GEL101 for an isotonic paste option.

$8.00 - $16.00 Select options

Stim Electrode, Human-safe The Human-safe Stimulation Electrode HSTM01 provides a superior degree of safety and comfort when using a Voltage Stimulator for human stimulation. The ergonomic design allows the user to focus on the electrode placement instead of worrying about holding the electrode. Subjects depress the red safety switch to allow the software-controlled stimulus presentation through. To stop…

$265.00 Add to cart

SuperLab System for MP36/35 or MP36R The STP35W is a stand-alone system that measures subject responses to visual or auditory stimuli. Includes SuperLab, c-pod, and response box. SuperLab -  present visual stimuli on a computer screen, or auditory stimuli via headphones or speakers, and simultaneously (1 ms resolution) send trigger signals for data synchronization and collection purposes to an MP36/35 BSL System…

Login for pricing Add to cart

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$190.00 Add to cart

Photoplethysmogram for Pulse Waveform - MP3X/45 The SS4LA photoplethysmogram (PPG) transducer operates with the data acquisition unit to record the blood volume pulse waveform via optical methods. The SS4LA consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the…

$245.00 Add to cart

Respiratory Effort Transducer - MP3X/45 The SS5LB records respiratory effort. The transducer is a rugged strain assembly that measures the change in thoracic or abdominal circumference. The transducer presents minimal resistance to movement and is extremely unobtrusive. Due to its novel construction, the SS5LB can measure extremely slow respiration patterns with no loss in signal amplitude while maintaining excellent linearity…

$295.00 Add to cart

Temp., surface/fast-response, BSL The SS6L is used to measure temperature on a variety of body locations. The SS6L is also appropriate for use in locations where temperature changes rapidly, as with the temperature changes of inspired/expired breath. TAPE1 can be used to hold the SS6L in place. Replacement sensor available: RX202A

$155.00 Add to cart

Stethoscope, BSL The SS30L was developed to teach students the standard procedure for listening to heart sounds and Korotkoff sounds with a normal stethoscope and at the same time record sound data. A microphone in the stethoscope simultaneously records the sound the student is hearing, and the BSL software will display the soundwave during and after recording.…

$265.00 Add to cart

Noninvasive Cardiac Output Sensor - MP3X The SS31LA simultaneously measures Impedance Magnitude (Zo; labeled “Z” on the module) and Derivative of Impedance Magnitude (dZ/dt; labeled “DZ” on the module). The SS31LA noninvasively records the parameters associated with Cardiac Output measurements. Measure changes in Cardiac Output under a variety of conditions: laying down, sitting up, standing up, and post-exercise. Use the Kubicek…

Request Price Add to cart

EDA Lead Set Lead Set for Electrodermal Activity The EDA/GSR Lead connects to a single input channel to record electrodermal activity (changes in skin conductance) or, with modified setup, skin resistance from two EL507 disposable EDA/GSR (isotonic gel) electrodes. SS57LA EDA/GSR Lead delivers accuracy over its specified range to within 5% with no calibration required. Biopac Student Lab Systems: requires BSL 4.1…

$210.00 - $265.00 Select options

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

New Citations | Respiration Analysis and More

Comparing Diaphragm Tissue Between Healthy and Ill Patients The human diaphragm is one of the primary muscles used in respiration, contracting and expanding to control breathing. To measure how much diaphragms move for critically ill patients (in an Intensive Care Unit) compared to diaphragms in a healthy subject, patients at “Papageorgiou” General Hospital in Thessaloniki, […]

BIOPAC Systems Helps STARK Industries Launch VITAL Ventilator for NASA JPL

BIOPAC’s ventilator testing equipment and expertise supports STARK Industries’ effort to manufacture, validate, and test NASA JPL’s VITAL Ventilators Goleta, California – June 16, 2020 BIOPAC Systems, Inc. announced a partnership with STARK Industries, LLC to provide ventilator validation and testing equipment for the mass production of ventilators. STARK Industries was awarded a global license […]

Read All
Request a Demonstration
Request a Demonstration