Study EEG under a variety of conditions to explore relaxation and brain rhythmsthe software can filter and display each rhythm separately: alpha, beta, delta, and theta. Study alpha rhythms in the occipital lobe, reaction times, and hemispheric asymmetry. Use the system to demonstrate changes in the parasympathetic and sympathetic nervous system. Add EOG (occipital signal) to study eye movement, saccades, tracking, angular displacement, or ocular fixations. Use the stimulator to study evoked responseauditory, visual, or somatosensory. Record reaction time and measure nerve conduction velocity. The system samples quickly enough to easily record spontaneous nerve activity from small animals and insects.
Name | Description | Cart |
---|---|---|
General-purpose Electrodes | These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.… | $45.00 - $340.00 Select options |
High Impedance Cables | Micro-electrode interface cables for MP36/36R, MP35, MP30, or MP45* These fully-shielded, unity gain, high-impedance, differential input, electrode interface cables permit high resolution recording of biopotential signals. These interface cables incorporates dual ultra-high impedance buffer amplifiers (one for Vin+ and one for Vin-) to allow for connections to needle electrodes, wire electrodes, or very small surface electrodes… | $242.00 Select options |
Voltage Stimulators | The Voltage Stimulator connects to either the MP36/MP35 or the MP30. BNC output provides compatibility with a variety of stimulator cables. The voltage Range and Level are manually controlled while the pulse timing is user-adjustable and controlled by the Biopac Student Lab software. The Voltage Range (.025-10 Volts or .12-100 Volts) is established by a switch with… | |
Stim Electrode, Human-safe | The Human-safe Stimulation Electrode HSTM01 provides a superior degree of safety and comfort when using a Voltage Stimulator for human stimulation. The ergonomic design allows the user to focus on the electrode placement instead of worrying about holding the electrode. Subjects depress the red safety switch to allow the software-controlled stimulus presentation through. To stop… | $308.00 Add to cart |
SuperLab System for MP36/35 or MP36R | The STP35W is a stand-alone system that measures subject responses to visual or auditory stimuli. Includes SuperLab, m-pod, response box, and light sensor. SuperLab - present visual stimuli on a computer screen, or auditory stimuli via headphones or speakers, and simultaneously (1 ms resolution) send trigger signals for data synchronization and collection purposes to an MP36/35… | |
Lead set, shielded, BSL | This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons… | $245.00 Add to cart |
Low Voltage Stimulator, BSL MP35 | Use the low voltage stimulator with any electrode or lead with a BNC connector (such as needle electrodes or clip leads) for direct stimulation of animal or tissue preps. Control the stimulus with the Output Control option of the BSL PRO software. Monitor the output directly on the computer without any external cable. Interface options:… | $303.00 Add to cart |
The NICO Smart Amplifier is specifically designed to measure thoracic impedance for performing noninvasive cardiac output measurements. The amplifier terminates in two connectors for impedance (Z) and its derivative (dZ), and has a 3 m cable that connects directly to an AMI100D Amplifier Input Module. Use with EL526 strip electrodes and CBL246 adapter or with EL500 […]
View AllThe autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]
BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]
Read All