Neurophysiology – Biology

Study EEG under a variety of conditions to explore relaxation and brain rhythmsthe software can filter and display each rhythm separately: alpha, beta, delta, and theta. Study alpha rhythms in the occipital lobe, reaction times, and hemispheric asymmetry. Use the system to demonstrate changes in the parasympathetic and sympathetic nervous system. Add EOG (occipital signal) to study eye movement, saccades, tracking, angular displacement, or ocular fixations. Use the stimulator to study evoked responseauditory, visual, or somatosensory. Record reaction time and measure nerve conduction velocity. The system samples quickly enough to easily record spontaneous nerve activity from small animals and insects.

Hardware

Name Description Cart
General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$42.00 - $310.00 Select options

High Impedance Cables Micro-electrode interface cables for MP36/36R, MP35, MP30, or MP45* These fully-shielded, unity gain, high-impedance, differential input, electrode interface cables permit high resolution recording of biopotential signals. These interface cables incorporates dual ultra-high impedance buffer amplifiers (one for Vin+ and one for Vin-) to allow for connections to needle electrodes, wire electrodes, or very small surface electrodes…

$220.00 Select options

Voltage Stimulators The Voltage Stimulator connects to either the MP36/MP35 or the MP30. BNC output provides compatibility with a variety of stimulator cables. The voltage Range and Level are manually controlled while the pulse timing is user-adjustable and controlled by the Biopac Student Lab software. The Voltage Range (.025-10 Volts or .12-100 Volts) is established by a switch with…

Login for pricing Select options

Stim Electrode, Human-safe The Human-safe Stimulation Electrode HSTM01 provides a superior degree of safety and comfort when using a Voltage Stimulator for human stimulation. The ergonomic design allows the user to focus on the electrode placement instead of worrying about holding the electrode. Subjects depress the red safety switch to allow the software-controlled stimulus presentation through. To stop…

$280.00 Add to cart

SuperLab System for MP36/35 or MP36R The STP35W is a stand-alone system that measures subject responses to visual or auditory stimuli. Includes SuperLab, m-pod, response box, and light sensor. SuperLab -  present visual stimuli on a computer screen, or auditory stimuli via headphones or speakers, and simultaneously (1 ms resolution) send trigger signals for data synchronization and collection purposes to an MP36/35…

Login for pricing Add to cart

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$200.00 Add to cart

Low Voltage Stimulator, BSL MP35 Use the low voltage stimulator with any electrode or lead with a BNC connector (such as needle electrodes or clip leads) for direct stimulation of animal or tissue preps.  Control the stimulus with the Output Control option of the BSL PRO software. Monitor the output directly on the computer without any external cable. Interface options:…

$275.00 Add to cart

Spotlight On
BioNomadix Wireless 2 Ch Goniometry Amplifier

BioNomadix 2CH Wireless Goniometry Amplifier

The BioNomadix two channel wireless goniometry amplifier is a dual output device that provide simultaneous measurements around two orthogonal rotational axes (e.g., wrist flexion/extension and radial/ulnar deviations). These units interface with the MP160 (or older MP150) data acquisition and analysis platform and AcqKnowledge software, allowing advanced analysis for multiple applications and supporting acquisition of a broad range of signals and measurements. BN-GONIO can support any […]

View All
Latest News

New Citations | BIOPAC in Ergonomics

Whether using specialized equipment, performing repetitive tasks, or simply going about our daily work routine, the effects of design in our environment as well as the tools we use and the way we use them can impact our health, work performance, and quality of life. Here are a few studies that have recorded and analyzed […]

EDA Guide Available

BIOPAC’s comprehensive EDA Guide provides an introduction to Electrodermal Activity (EDA or GSR) and details topics including: EDA Complex: SCL, SCR, tonic, phasic, specific SCR, non-specific SCR Participant Prep & Electrode Placement Data Recording tips Automated EDA Analysis Routines Digital input to Stim Events Stim-Response Analysis Derive Phasic EDA from Tonic Event-related EDA Analysis Locate […]

Read All
Request a Demonstration
Request a Demonstration