Cardiovascular – Biology

Lessons include blood pressure, ECG analysis, heart sounds, and pulse. Students can make single-, three-, six- and 12-lead ECG recordings, familiarizing themselves with Einthovens triangle and mean electrical axis of the frontal plain. Students perform blood pressure measurements using a cuff, with stethoscope, employing Korotkoff sounds to make determinations of systolic/diastolic pressure. Students can also utilize the latest technology for continuous noninvasive BP recordings. Use the bioimpedance cardiac output (CO) module on human and animal subjects to record stroke volume and cardiac output. By measuring continuous BP, simultaneous with flow (cardiac output), students can examine vascular resistance.

Hardware

Name Description Cart
General-purpose Electrodes These pre-gelled disposable electrodes have a circular contact and are most suitable for short-term recordings, including surface EMG, ECG, EOG, etc. The small vinyl backing allows close electrode placement where necessary, and a slightly less firm adhesive allows "ouchless" removal. The electrodes incorporate liquid electrolyte gel and moderately-high chloride salt concentration for quick, accurate readings.…

$40.00 - $295.00 Select options

Bioimpedance Strip Electrodes Use as an alternative to band electrodes This unique disposable strip electrode is designed for bioimpedance applications. The electrode is sticky hydrogel with carbon film backing and industry-standard medical grade adhesive, medium tackiness. The silver-silver chloride (Ag/AgCl) electrode provides accurate and clear transmission of surface biopotentials and is latex free. Advantages of the Strip Electrode…

Read more

Multi-lead ECG Cable (MP3X) The SS29L Multi-Lead ECG Cable permits high resolution electrodcardiogram recordings. The lead set will allow you to simultaneously record Leads I, II, III, aVR, aVL, aVF, plus one precordial chest lead. A 12-Lead ECG recording can be obtained by alternating the chest lead electrode from position V1 through V6. The cable is terminated in three…

$370.00 Add to cart

Lead set, shielded, BSL This fully-shielded cable assembly permits high resolution recording of biopotentials using our EL500 series disposable electrodes. The 2 meter adapter is terminated with standard pinch connectors to interface with EL500 series snap electrodes. The SS2LB interfaces with Biopac Student Lab data acquisition units (MP3X or MP45) and the MP36R research unit. Compatible releases BSL Lessons…

$190.00 Add to cart

Photoplethysmogram for Pulse Waveform - MP3X/45 The SS4LA photoplethysmogram (PPG) transducer operates with the data acquisition unit to record the blood volume pulse waveform via optical methods. The SS4LA consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the…

$245.00 Add to cart

Stethoscope, BSL The SS30L was developed to teach students the standard procedure for listening to heart sounds and Korotkoff sounds with a normal stethoscope and at the same time record sound data. A microphone in the stethoscope simultaneously records the sound the student is hearing, and the BSL software will display the soundwave during and after recording.…

$265.00 Add to cart

Noninvasive Cardiac Output Sensor - MP3X The SS31LA simultaneously measures Impedance Magnitude (Zo; labeled “Z” on the module) and Derivative of Impedance Magnitude (dZ/dt; labeled “DZ” on the module). The SS31LA noninvasively records the parameters associated with Cardiac Output measurements. Measure changes in Cardiac Output under a variety of conditions: laying down, sitting up, standing up, and post-exercise. Use the Kubicek…

Request Price Add to cart

Spotlight On
free BIOPAC webinar

Combine the Newest 20 Channel EEG System with Multiple Physiology Signals

B-Alert X-Series Systems offer top of the line wireless EEG. Participants are much more comfortable in B-Alert systems, ensuring the best outcome for data quality. With a super easy setup, B-Alert X24 allows researchers to collect up to 20 channels of EEG and concurrently record physiology signals in combination with BIOPAC’s data collection systems.

• Learn new features of the B-Alert X24, including the 10/20 electrode montage system
• Discover real-time subject classifications for engagement, confusion/distraction, drowsiness, workload, and stress
• Integrate and synchronize other physiology signals including EDA, EMG, respiration, and temperature

Live webinar Jan. 28th 8AM PST / 11AM EST

Register Now
Latest News

New Citations | How Sudoku Helps With Rehabilitation & More!

Rehabilitation with Sudoku Sudoku, in the last 10 years, has seen a resurgence in popularity as a challenging logic game. Scientists have also fallen in love with the math puzzle, as a useful tool for neurorehabilitation and cognitive workouts. This study measured prefrontal cortical activity with a continuous-wave fNIR Imager to observe how participants solved […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]