Indirect BP Measurement, Ventricular Systole and Diastole, Korotkoff Sounds, Mean Arterial Pressure

In the Systemic Blood Pressure lesson, students use the auscultatory technique to record arterial blood pressure.

Students record blood pressure using a cuff, pump and pressure gauge, Korotkoff sounds using a microphone, and ECG using Lead II. The system will display cuff pressure, Korotkoff sounds and ECG for easy determination of systolic blood pressure. Students view the Korotkoff sounds and listen to them with a stethoscope or headphones.* They will perform a task designed to change their blood pressure.

* BSL 4.0.2 and above includes a headphone output option for monitoring stethoscope sounds through OUT1/OUT1A/40HP via the MP Analog Output or headphone jack.

Experimental Objectives

  1. To use an Auscultatory method for an indirect determination of systemic arterial and diastolic blood pressure and to correlate the appearance and disappearance of vascular sound with systolic and diastolic pressure respectively.

  2. To measure, record and compare systemic arterial blood pressure in the right arm and the left arm of the same subject under identical conditions.

  3. To measure, record and compare systemic arterial blood pressures in the same subjects under different experimental conditions of rest and exercise.

  4. To compute, record and compare pulse pressure and mean arterial pressure under different experimental conditions of rest and exercise.

  5. To correlate the Korotkoff sounds to the mechanic events of the cardiac cycle.

Tasks Performed by the Student

BSL Lessons are designed to allow at least four students to record and save data in a normal lab period (60-90 minutes). Typically, labs work most efficiently with three or more students working together at each BSL station.

Videos

BSL L16 Calibration SS19L

BSL 4 L16 Blood Pressure

Biopac Student Lab Student Download

Lesson Hardware

This lesson requires a Biopac Student Lab (BSL) System and the following hardware. If your BSL System does not include all hardware items, expand your system by selecting required items below. For more details, review the Lesson: L# BSL Lessons - see the Lab Manual or launch BSL; A# and H# BSL PRO Lessons, click the PDF link above to review full setup, recording, and analysis procedures.

Item Name Cart
SS19L Blood Pressure Cuff, BSL Add to Cart
Select Option Stethoscope for BSL Add to Cart
SS2LB Lead set, shielded, BSL Add to Cart
GEL1 Electrode gel 50 g Add to Cart
ELPAD Abrasive Pads 10/pk Add to Cart
EL503 Disp. Gen-purp electrode 100/pk Add to Cart
Spotlight On
free BIOPAC webinar

Engineering the Future: Preparing BME Students with Practical Labs

Do your students feel ready for engineering in the real world? Are they prepared for real-life scenarios that include human factors and ergonomics?

Understanding human physiology enables engineers to create quality biomedical devices for real-life applications. Join us as we explore why physiology should be a prerequisite for engineering students and learn how Biopac Student Lab can help prepare the next generation of engineers.

What You Will Learn:
• How to plan engineering curriculum around real-world applications
• Innovative ideas for student engagement and project-based learning
• Tools for teaching cardiovascular, respiratory, SpO2, and EEG concepts for engineering students
• How to acquire essential resources for engineering labs
• Overview of the Biopac Student Lab

Live Webinar: April 29th at 9AM PT/10AM ET

Register Now
Latest News

New Citations | Rehabilitating the Rehab Industry & More!

BIOPAC provides software and hardware that allows engineers to study the body. Here are a few notable studies using BIOPAC equipment for Biomedical Engineering research. Rehabilitating the Rehab Industry Could physical therapy be done from the comforts of your own home? If possible, this would open the door for more people with all sorts of ailments to […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration