BIOPAC® Systems, Inc. Logo

H21 Impedance Cardiography

This BSL PRO lesson describes hardware and software setup of the BSL System to record ECG, Impedance (Z0), and Derivative Impedance (dZ/dt), and measure relative differences in Cardiac Output and Stroke Volume using a noninvasive bioimpedance technique.

The Lesson Procedure for BSL 4.0.1 or above includes an extensively updated physiological introduction that covers Cardiac Output as a Function of Stroke Volume and Heart Rate, Cardiac Output as Related to Mean Arterial Pressure and Peripheral Resistance, How to Determine Cardiac Output, Principles of Impedance Cardiography (ICG), and Ideas for eliciting cardiovascular responses through physical maneuvers and psychological tasks.

Suggested reading: Methodological Guidelines for Impedance Cardiography , PSYCHOPHYSIOLOGY, Vol. 27, No. 1.

Experimental Objectives

For BSL 4.0.1 or above:

  1. Learn impedance cardiography techniques.
  2. Measure the change in cardiovascular responses—Stroke Volume (SV), Cardiac Output (CO), and Heart Rate (HR)—to postural changes (supine vs. standing).
  3. Examine how HR and SV interact to maintain CO.
  4. Experiment with other ways to elicit cardiovascular responses (active learning).

For BSL 4.0.0 or below:

  1. Obtain stroke volume data.
  2. Obtain cardiac output data.
  3. Correlate heart valve opening/closing with cardiac output.

Tasks Performed by the Student

BSL 4.0.1 or above: Record Subject in the supine position then in standing position.
BSL 4.0.0 or below: Subject will sit, stand, and lie down.

Videos

Biopac Student Lab Student Download

Student Prep & Distance Learning

Click the link(s) below for sample data and/or lesson procedure video(s), BSL PRO Lesson procedures (PDF) for human lessons*, and graph template files (*.gtl) for BSL PRO Lessons. If more than one .gtl is available, download the .gtl with the _suffix to match BSL version and hardware.

Lesson Hardware

This lesson requires a Biopac Student Lab (BSL) System and the following hardware. If your BSL System does not include all hardware items, expand your system by selecting required items below. For more details, review the Lesson: L# BSL Lessons - see the Lab Manual or launch BSL; A# and H# BSL PRO Lessons, click the PDF link above to review full setup, recording, and analysis procedures.

ItemNameCart
SS31LANoninvasive Cardiac Output Sensor - MP3XAdd to Cart
EL504Disp. Cloth electrode 30/pkAdd to Cart
SS2LBLead set, shielded, BSLAdd to Cart
EL503Disp. Gen-purp electrode 100/pkAdd to Cart
GEL1Electrode gel 50 gAdd to Cart
SS30LStethoscope, BSLAdd to Cart
ELPADAbrasive Pads 10/pkAdd to Cart
Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

BIOPAC Systems Helps STARK Industries Launch VITAL Ventilator for NASA JPL

BIOPAC’s ventilator testing equipment and expertise supports STARK Industries’ effort to manufacture, validate, and test NASA JPL’s VITAL Ventilators Goleta, California – June 16, 2020 BIOPAC Systems, Inc. announced a partnership with STARK Industries, LLC to provide ventilator validation and testing equipment for the mass production of ventilators. STARK Industries was awarded a global license […]

New Citations | Kick Off Summer with New Research in Exercise Physiology!

Comparing Muscle Movement and Involvement between Boxing Punches In the fast-paced, high-intensity combat sport of boxing, the right punch can win a fight. However, boxing is also a sport where opponents can become exhausted in mere minutes of action, and prioritizing their strength is key to winning a fight. This team recorded EMG on test […]

Read All
Request a Demonstration
Request a Demonstration