The BSL System employs a wide array of transducers that transform physical measures into electrical signals. The generic input design of the MP36/35 acquisition unit allows it to interface a huge variety of third-party or completely unique transducers. Students can use the BSL software to linearize and calibrate transducers and then compare results to expected values. Relate fundamental physical standards to complicated measures. For example, calibrate the airflow transducer with a syringe, and then use the airflow transducer to calibrate the respiration belt.
Name | Description | Cart |
---|---|---|
Disposable Bacterial Filters | Disposable bacteriological filters for use with 22 mm breathing circuits, such as BIOPAC pneumotach transducers SS11LA, TSD117, or SS11. These filters remove airborne bacteria. Pore size—VFE: 3.1 micron; BFE: 2.8 micron MRI Use: MR Safe (see Specifications for components) | $48.00 - $745.00 Select options |
Disposable Mouthpiece | These mouthpieces connect to the TSD117 pneumotach transducer and other 22 mm breathing circuits. Connects directly to the AFT1 bacterial filter, AFT22 non-rebreathing T valve (via AFT11C) and the TSD117 air flow transducer. (Pkg. 10 or 250) MRI Use: MR Safe (see Specifications for components) | $17.00 - $182.00 Select options |
Disposable Noseclip | These nose clips gently squeeze the nostrils shut to prevent errors when using mouth-breathing circuits. Available in packs of 10 or 250. MRI Use: MR Safe (see Specifications for components) | $19.00 - $242.00 Select options |
Custom Input/Output | Use these kits to adapt third-party transducers to the CH inputs on BIOPAC's MP36/36R . Kits include a Simple Sensor connector, cable. and components to properly interface with full, half, or quarter bridge transducers (pressure, force, strain, acceleration, sound, etc.). See the Transducer Connector Interface Series for existing transducer interface options | |
Cal. Syringe, 600 ml | Medium pump syringe used for injecting a precise volume of air (600 ml) through airflow assemblies for precise calibration. The AFT6A fits (ridged) 27 mm OD, 30 mm OD, and 15 mm ID. Fits directly to AFT13 (30 mm) filter and mouthpiece AFT23 (27 mm) non-rebreathing T-valve with replacement valves Use coupler AFT11A to connect… | $198.00 Add to cart |
Cal. Syringe, 3 liter | The AFT27 3.0 Liter Calibration Syringe is certified to have a volume that meets or exceeds an accuracy of 0.5% of the total displacement volume (3 liters ±0.5%). This adjustable aluminum calibration syringe is shipped with the volume locked to 3.0 L and BIOPAC templates and software settings are set for 3 L. The locking collar and… | $429.00 Add to cart |
Interface Grass | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. Use this 6-pin male interface to connect to Grass or Gilson transducers. | $242.00 Add to cart |
Interface Beckman 5 pin | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. | $160.00 Add to cart |
Interface WPI | Use this interface (8-pin, female) to connect your existing WPI transducer or certain AD Instruments (CB Sciences) and iWorx (FT-100 Force) transducers to the Biopac Student Lab MP3X data acquisition unit. | $182.00 Add to cart |
Interface Lafayette | The BSL-TCI3 (9-pin, female) connects Lafayette Instruments and Narco Bio-Systems equipment to the Biopac Student Lab MP3X data acquisition unit. | $182.00 Add to cart |
Interface Honeywell | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. Honeywell transducers – 6 pin | $195.00 Add to cart |
Interface Mod Phone | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. BSL-TCI5 Modular phone jack connector 4 pin | $220.00 Add to cart |
Interface Beckman | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. BSL-TCI6 for Beckman transducers – 12 pin | $369.00 Add to cart |
Interface Nihon Koden | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. BSL-TCI7 Nihon Kohden transducers – 5 pin | $182.00 Add to cart |
Interface Narco 7 | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. BSL-TCI8 Narco transducers - 7 pin | $248.00 Add to cart |
Interface Fukuda | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. BSL-TCI9 Fukuda transducers 8 pin | $160.00 Add to cart |
Interface Thornton | BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. Use this cable to interface with 5-pin Thornton transducers (type 4xx). | $182.00 Add to cart |
Interface MP30 to Piezo | Use this interface (Piezo, BNC) to connect your existing transducer to the Biopac Student Lab MP30 data acquisition unit. BIOPAC offers a line of transducer connector interfaces (TCIs) to adapt your existing transducers to the Biopac Student Lab MP data acquisition unit. Works with a variety of transducers, including the iWorx PT-100. | $160.00 Add to cart |
Interface 1/4 phono | Use this interface (Stereo, 1/4", Phono socket) to connect your existing transducer to the MP3X data acquisition unit for Biopac Student Lab (MP36/35/30) or Research Systems (MP36R). Works with a variety of transducers, including Lafayette 76613 Force. | $160.00 Add to cart |
Interface 5-pin DIN Vernier | Use this interface (5-pin DIN, female) to connect your existing transducer to a CH input on a BIOPAC data acquisition unit (MP36, MP36R, MP45, MP35, MP30). | $160.00 Add to cart |
Interface BT con., Vernier | The BSL-TCI16 (BT - British Telephone RH) connects the BIOPAC RXPROBE-02A Dissolved Oxygen probe or Vernier analog sensing equipment to a BIOPAC data acquisition unit CH input (MP36, MP36R, MP46, MP45, MP35, or MP30). | $182.00 Add to cart |
Interface 5-pin Intellitools | Use this interface (5-pin DIN, female) to connect your existing transducer to the Biopac Student Lab MP3x data acquisition unit. Works with a variety of transducers, including the Intelitools Physiogrip transducer. | $160.00 Add to cart |
Interface 2 mm Hg Strain | This interface cable (two 2 mm sockets*) adapts an existing BTI / Monarch type liquid metal (mercury or indium gallium) strain gauge silastic transducer to the Biopac Student Lab MP36/35/30 data acquisition unit or MP36R research data acquisition unit. Liquid metal transducers are useful for plethysmograph studies, male sexual arousal studies, joint swelling studies, vascular… | $369.00 Add to cart |
Interface 6-pin Intellitool | Use this interface (6-pin mini DIN, female) to connect your existing Intelitool transducer to the Biopac Student Lab MP30 data acquisition unit. | $248.00 Add to cart |
Interface 3.5 mm Intellitools | Use this interface (mini 3.5 mm phono jack, female) to connect your existing Intellitools transducer to the Biopac Student Lab MP3x data acquisition unit. | $160.00 Add to cart |
Interface BNC pH probe | Use this interface (BNC) to connect your existing pH transducer to a Biopac Student Lab MP3X data acquisition unit. Works with a variety of probes, including the BIOPAC RXPROBE-01 pH Probe. | $160.00 Add to cart |
Interface SS2L to SS39L | The electrode interface connects the SS2L Shielded Lead Assembly to the SS39L Breadboard for circuit configurations that require electrodes. One BSL-TCI22 is shipped with the SS39L. | $61.00 Add to cart |
Respiratory Effort Transducer - MP3X/46/45 | The SS5LB records respiratory effort; the transducer is a rugged strain assembly that measures the change in thoracic or abdominal circumference. The transducer presents minimal resistance to movement and is extremely unobtrusive. It connects to an MP3X/46/45 input channel. Due to its novel construction, the SS5LB can measure extremely slow respiration patterns with no loss… | $340.00 Add to cart |
High-performance mobile fNIR Imaging Systems are stand-alone functional brain imaging solutions for continuous NIR spectroscopy (NIRS). These top of the line systems provide cognitive function assessment and eliminate a great many of the drawbacks of a functional MRI. Mobile subjects are comfortable and can respond naturally in real-world situations to take a test or perform mobile […]
View AllThe mind and body work together in many ways and psychophysiology research provides insight to these connections. BIOPAC has a variety of systems to power your emotion, arousal, stress, cognitive assessment, group interaction, startle, and other psychophysiology research. Here are some recent studies that have used BIOPAC systems for psychophysiological research… Skin conductance, facial EMG, […]
For immediate release: January 4, 2023 Amiens, France and GOLETA, California, USA Seenel Imaging SAS and BIOPAC Systems, Inc. have formed a long-term global partnership to distribute MedelOpt®, Seenel Imaging’s groundbreaking wearable neuroimaging device for the neuroscience research market. Seenel Imaging, based in France, continues its international expansion by partnering with BIOPAC Systems, […]