ICG (thorax)

Cardiac Output amplifier

To record ICG (thorax) use the following BIOPAC hardware:

Standard setup:

  1. Noninvasive Cardiac Output Amplifier
    • NICO100D Smart Amplifier
      measures thoracic impedance for performing noninvasive cardiac output measurements
  2. Lead Sets
    • LEAD131 for tetrapolar electrode configurations
      provides 4 x 50 cm clip leads: White I+, Red Vin+, Green Vin, Black I
    • LEAD132 for spot electrode configurations
      provides 8 x 64 cm clip leads (4 x 25 cm wires each split to 2 x 36 cm leads):
      2 x White I+, 2 x Red Vin+, 2 x Green Vin, 2 x Black I
  3. Electrodes
    • EL516 Bioimpedance Strip Electrodes: sticky hydrogel, carbon film backed, standard snap contact
    • EL500 Paired Electrodes: Fixed-spacing, pre-gelled peel-and-stick foam-backed sheet with two snap contacts

For use in MRI environment:

  1. MR-Compatible Noninvasive Cardiac Output Amplifier
    • NICO100C-MRI Impedance Cardiography (ICG) Noninvasive Cardiac Output Module for Magnetic Resonance Imaging
  2. Lead Set
    • MECMRI-NICO filtered cable set
  3. Electrodes
    • EL526 Carbon fiber, foam-backed, pre-gelled strip electrodes with TP leads
      16.5 cm x 1.3 cm (6.5″ x 0.5″) sheet with 4 x 15 cm lead cables terminated in 1.5 mm Touch Proof sockets
Spotlight On
BIOPAC ECG

ECG Smart Amplifier

Easily record great ECG data and derived signals for heart rate, RR interval, and R-wave amplitude. BIOPAC’s new Smart Amplifiers are designed for great data. Smart Amplifiers improve performance by amplifying the physiological signal close to the subject, which allows a high-level voltage connection to the data acquisition system and reduces noise artifact. AcqKnowledge Smart […]

View All
Latest News

New Citations | BIOPAC in HRV Analysis Research

BIOPAC provides researchers with a complete range of tools to gather data on heart rate variability (HRV). The following studies demonstrate just some of the ways in which HRV research benefits from the implementation of BIOPAC hardware and software solutions. PTSD and HRV Post-traumatic stress disorder (PTSD) has been associated with dysfunction of the autonomic […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration