BIOPAC® Systems, Inc. Logo

Ventilator Validation and Test Equipment

Use to validate ventilator performance

Parts have been used thousands of times by academic research institutions

Immediate delivery to support rapid hardware development & field testing for COVID-19 response

Request More Info
View Cart “Inline Coupler for O2 Sensor” has been added to your cart.
ventilator testing hardware
Part #: VVK100-SYS

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical.

The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes a laminar flow transducer (±120 LPM), airway pressure transducer, differential amplifiers, calibration syringe, and a data acquisition system with automated pulmonary function analysis software to assist in the validation of ventilators. Multiple systems can operate, in concert, to increase productivity and maximize efficiency.

Ventilator Validation Systems flyer —plus see video overview, components, and setup in “Details” below.

Use cases:
– BIOPAC Helps STARK Industries Launch VITAL Ventilator for NASA/JPL-Caltech
– BIOPAC Supplies Ventilator Testing Systems to Ford to Mass Produce Ventilators
BIOPAC Ventilator Test Kits Used for Virgin Orbit’s COVID-19 Ventilators 
– MIT & Harvard: “iSAVE” Rapidly deployable system to expand ventilator capacity

We’re here to discuss your pilot project or scaling requirements!

See More...

VENTILATOR SUPPORT

  • Ventilator Field Verification
  • Failure Analysis

VENTILATOR PRODUCTION

  • Ventilator Manufacturing Testing/Validation
  • NDT for Automated Test Analysis
  • Troubleshooting

VENTILATOR DEVELOPMENT

  • Ventilator Pressure and Flow Measurements
  • Relief and PEEP Valve Validation
  • Flow and Pressure Regulator Evaluation
  • Cycle Timing Analysis
  • Leak Detection
  • Ventilator Mode Analysis (ACV, SIMV, PCV, PSV, APRV, etc.)
  • Oxygen Percentage Measurement*
  • Temperature and Humidity Measurement*

Ventilator Validation
View Spec PDF

Are You Looking for These?

Part #: VVK100-SYS
Categories: Airflow & Gas Analysis - Research

Details

Components

The VVK100-SYS includes

  • MP160WS/W 16-channel Data Acquisition & Analysis system for Windows or Macintosh. The MP160 system can monitor eight ventilators (pressure, volume), simultaneously.
  • TSD157B-MRI-01 laminar flow transducer with Amplifier (DA100C) for precision ventilator bidirectional airflow measurements; TSD157B-MRI-01 consists of TSD160A pressure transducer + RX157 laminar flow head (±120 LPM) with silicone tubing (1 m). Can be inserted, in-line, to typical hospital ventilator systems. Airflow transducer calibration and verification is straightforward.
  • AFT27 3-liter Calibration Syringe is included for calibration and validation and is certified to meet or exceed an accuracy of 0.5% (3 liters ±0.5%).
  • TSD160D Differential Pressure Transducer with Amplifier (DA100C) that can interface with any pneumatic circuit to monitor airway pressure. When combined with the TSD157B-MRI-01, it is possible to monitor airflow and airway pressure to provide the user with real-time validation data of pump volume and pump pressure ranges.
  • AcqKnowledge software controls the hardware, displays the data, and analyzes the signals in real time.

*Optional Add-ons for Additional Measurements

  • Real-time Data Access: Data is available in real time for further third-party analysis by using the optional Network Data Transfer licensed feature, providing your systems with immediate network access to the data while the validation process is taking place.
  • Oxygen concentration: % Oxygen measurements—synchronized with flow cycling, use TSD301 Galvanic Oxygen Transducer + DA100C Transducer Amp; inline coupler AFT301 available—fits O2 sensor and 22 mm tubing.
  • STPD results: STPD results are needed to satisfy ISO Standards (e.g., ISO 80601-2-12). STPD reporting is the only method that permits ventilator performance comparison no matter altitude, temperature or humidity. To convert volumes from ATP (Ambient Temperature and Pressure Dry) to STPD (Standard Temperature Pressure Dry), use:

    1)  TSD302 Wide Air Range Temperature Transducer (in sampled flow stream)
    2) TSD303 Barometric Pressure Transducer (in ambient air)
    3) TSD304 Humidity Transducer (in sampled flow stream)
    4) TSD305 100 PSI Gauge Pressure Transducer

  • Water vapor pressure: use TSD302 temperature sensor, TSD303 barometric pressure sensor, and TSD304 relative humidity sensor.
  • Differential Pressure Calibration: Use the AFTCAL-160 NIST certified Differential Pressure Manometer (Range ±2 psi, ±140.6 cm H2O) to calibrate the TSD160 series of differential pressure transducers.
  • CPAP mode validation: use the TSD157B-MRI-01 laminar flow transducer included with the system for very low flow and unidirectional measurements (less than 50 L/min).
  • Flow testing over multiple dynamic rangesContact BIOPAC to review specific testing requirements and recommended physical configurations.
  • Interfacing Accessories: BIOPAC offers a wide range of tubing, adapters, bacterial filters, valves, and related accessories. For example, AFT17 tubing will interface between the TSD160D transducer and the ventilator breathing circuit.

Setup

Ventilator Validation Setup

Snap the BIOPAC modules together: MP160 – AMI100D – DA100C (for TSD157B-MRI-01) – DA1000C (for TSD160D) – optional DA100C (for TSD301)

Connect the TSD157B-MRI-01 Laminar Flow Transducer to a DA100C Amplifier.

Connect the TSD160D Differential Pressure Transducer to a DA100C Amplifier.

optional Connect the TSD301 Galvanic Oxygen Transducer to a DA100C Amplifier.

Connect the Transducers to the ventilator circuit (add tubing, filters, etc. as required).

Technical Application Reference

  • The Ventilator Validation & Testing Technical Application Reference covers how to connect the ventilator validation kit (VVK100-SYS) to a standard, typical ventilator to allow for its verification, ventilator test calibration, and measurements for ventilator validation: Pressure and Timing; Cough Pressure Release (obstruction valve); Positive End-Expiratory Pressure (PEEP); Pressure; Oxygen Concentration; Air Flow & Volume.

ventilator test connections


BIOPAC products are used by 99% of the world’s top universities
and have been cited ~49,800 times.

Videos

Ventilator Validation System

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

AcqKnowledge GUI Overview

Support

Knowledge Base

Recommended Items

Spotlight On
AcqKnowledge Workflow Action examples

Workflow Automation Licenses

Workflow—A Great Tool for Every Researcher! Automate AcqKnowledge with New Workflow Tool New automation tool significantly saves time and improves consistency with standardized procedures Workflow’s drag-and-drop interface allows you to automate and repeat the signal-conditioning and processing steps your protocol requires in an easy-to-use process without programming or scripting knowledge. Batch process multiple files with confidence […]

View All
Latest News

New Citations | BIOPAC in ANS Research

The autonomic nervous system (ANS) is responsible for regulating the functions of all the body’s organs. Take a look at this month’s citations to see how to apply BIOPAC’s tools and learn techniques for ANS research… Comparable responses to a wide range of olfactory stimulation in women and men. Scientific Reports, 13(1), 9059. Lillqvist, M., Claeson, […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration