BIOPAC® Systems, Inc. Logo

TEAM System – 1 person

Physiology Anywhere, for Groups or Individuals

RF telemetry physiology monitoring system

Simultaneously monitor multiple subjects in real time

TEAM Physiology Monitoring Starter System
Part #: TEAMSystem - 1A

Ideal for exercise physiology, sports conditioning , human factors, public health, and psychological studies

TEAMSystem-1A is an RF telemetry physiology monitoring system for one person. The TEAM System can be expanded to simultaneously monitor multiple people in real time, anywhere in a stadium, field or other wide-area setting. Each subject wears a BioHarness system that telemeters heart rate, respiration rate, posture, activity, and acceleration back to a central TEAM central recording station. A single TEAM recording station can receive data from multiple subjects.

See More...

   Request More Info

Ideal for wide-area monitoring

Use in stadium, gym, or athletic field.

Easily monitor multiple subjects

Intuitive, easy to read “dashboard.” Logging or live data.

Comfortable for subjects

Fabric-based dry contacts, small and lightweight, no wires.

TEAM Physiology Monitoring System for 1
View Spec PDF

Are You Looking for These?

Part #: TEAMSystem - 1A
Categories: BioHarness & TEAM—Physiology on a Strap - Research, Telemetry and Data Logging - Education
Subcategories: TEAM System - multiple subjects - Research, TEAM System - multiple subjects - Education

Details

Compatibility


BioHarness Smart Fabric Strap for TEAM System physiological monitoring

 • Key TEAM BioHarness™ sensors
– heart rate
– breathing rate (patented)
– activity
– posture

• Radio built in and memory for 24 days
• Works under extreme activity
• Fabric-based, dry contacts—no skin break down
• Comfortable over long periods, washable
• Unobtrusive, light and small
• No wires
• Logging or Radio

• Detect ventilatory (anaerobic) threshold
• Fitness and fatigue using well known methods
– Heart Rate reduction at end of activity
– Anaerobic threshold detection
• Biomechanical markers give context (at rest vs. active)

• Individually configurable thresholds and bio alarm algorithms for prioritization

Real-time physiology monitoring

TEAM status BioGauge

Displays vital signs, fatigue levels and system status
– Green: all is well
– Orange: monitor closely
– Red: person needs attention

Heart Rate (HR) zones at a glance
• HR as % of max
• HR < 65% Green
• HR 65 – 85% Orange
• HR 85 – 100% Red

Breathing Rate (BR) zones at a glance
• BR in relation to ventilatory threshold (Anaerobic threshold)
• BR < VT Green
• BR > VT < 15s Orange
• BR > VT > 15s Red
• VT is set as a default or specific to the individual

Bio Alarms for easy monitoring
• Heat stroke, hydration, over extertion
• Zone Training (HR and BR)
• deeper information on demand
• set thresholds for heart zones and anaerobic threshold

Monitor & Measure

All received data is recorded in the system database against the associated person
• Select sessions and create sub-session or areas of interest with the simple, intuitive interface
• Display time series data quickly and easily
• Monitor multiple people, multiple sessions and multiple variables
• Produce statistical data with a single click
• Summarize sessions and sub-sessions for comparison
– compare individuals or trend analysis for one person over multiple sessions

• Direct access to raw waveforms
• Exports to other analysis programs via CSV

Combine Measures for Valuable Information

HR VT plot Heart Rate alone is not the answer

  • Heart Rate is noisy when activity is high.
  • Heart Rate is shallow so accuracy moves a large amount between zones.
  • Heart is effected by anxiety and stress.
  • Heart Rate is effected by chemicals such as caffeine.
Ventilatorty Threshold - fitness over time Breathing rate measures metabolic change

  • Accurately measure VT2 (anaerobic threshold).
  • No mask required.
  • Heart Rate at VT2 measures fitness and fatigue.
  • Breathing Rate zones for effective training.
  • Measure during interval training or other activity.

BioHarness activity level

Easily measure heart rate recovery

  • BioHarness™ activity sensor makes recovery period easy to locate
  • HRR is a well known measure of fitness and fatigue.
  • Can also be used to signal thermal stress.

This is an updated version of TEAMSYSTEM-1, which is no longer available.

Note: BioHarness requires a computer with integrated Bluetooth or an external USB Bluetooth dongle (not included with system purchase).

Videos

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

Support

Downloads/Resources

Knowledge Base

Manual

Upgrade

Recommended Items

Spotlight On
short, lightweight pinch leads

LEAD115 Lighter Lead Series

New series of unshielded 45 cm electrode leads with thin cable; suitable for facial EMG and other areas where lighter, shorter lead cables are required. Use for female Touchproof connectors to pinch clip connectors—connect electrodes to either a C-series amplifier or an MEC. The pinch connectors are light weight and the lead cable tinsel wire […]

View All
Latest News

MEAP and BIOPAC used to quantify rapid changes in cardiovascular state

The new issue of Psychophysiology has a study “Quantifying rapid changes in cardiovascular state with a moving ensemble average” using MEAP for preprocessing/analysis and BIOPAC hardware and software for data collection, display, and storage. The proof of concept study demonstrates a viable method for the adoption of ICG measures across the field of psychophysiology. MEAP (moving ensemble […]

News Citations—fMRI & Temperature, Postpartum Depression, and Fibromyalgia

BIOPAC provides software and hardware that allow for research teams to record and analyze respiration activity in physiological experimentation. Here are a few notable studies covering MRI, ECG, and Laser Doppler Flow measurement. fMRI & Thermal Perception: The neural mechanisms underlying thermal perception (how hot or cold we perceive the temperature to be) have not been fully […]

Read All
Request a Demonstration
Request a Demonstration