Photoplethysmograph Transducer for MRI

Request More Info
View Cart “Photo Plethysmogram Amplifier for MRI” has been added to your cart.
PHOTO PLETHYSMOGRAPH FOR MRI
Part #: TSD200-MRI

The TSD200-MRI photoplethysmogram (PPG) transducer operates with the PPG100C-MRI to record the blood volume pulse waveform via optical (photoplethysmogram) methods. The TSD200-MRI consists of a matched infrared emitter and photo diode detector, which transmits changes in infrared reflectance resulting from varying blood flow. Blood is highly reflective of near infrared light wavelengths, due to the heme subunit of hemoglobin. When the PPG transducer is placed on the skin, in proximity to capillaries, the reflectance of the infrared light from the emitter to the detector will change in accordance to capillary blood volume. The PPG waveform peaks when capillary blood volume is maximized.

See More...

MRI Pulse Plethysmogram Trans.
View Spec PDF

Are You Looking for These?

Part #: TSD200-MRI
Categories: MRI Magnetic Resonance Imaging - Research
Subcategories: Transducers - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


The transducer optics are designed to sense diffuse surfaces, including the skin surfaces of finger or toe. The transducer is sensitive to Blood Volume Pulse (BVP) via photo-plethysmographic methods.

The Diode and Phototransistor are mounted side by side on parallel axis in a black polyurethane housing. The Phototransistor is encased in a dark epoxy package which filters out visible ambient light. The transducer has a shielded 3-meter cable.

The ergonomic housing design improves contact with the subject and helps reduce motion artifact.

The TSD200-MRI only operates with the PPG100C-MRI amplifier.

Connections

  • For MRI applications: Use the MECMRI-TRANS Cable/Filter to connect the TSD200-MRI to the PPG100C-MRI. See BIOPAC Application Notes regarding the proper installation of MECMRI cables for recording in an MRI environment.
  • For non-MRI applications: Connect the TSD200-MRI directly to the PPG100C-MRI.

MRI Use: Conditional to 7T

Condition: Conductive parts of transducer are electrically and thermally isolated from subject. (See Specifications for components.)

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Ventilator Validation Kit

Ventilator Validation and Test Equipment

The Ventilator Validation Kit supports new prototype development, existing design validation for production testing, mobile field testing and verification, and other uses where accurate pressure and flow measurements are critical. The Ventilator Validation Kit provides ventilator manufacturers and prototype developers with a complete solution for validating new medical/hospital-grade ventilator products intended for human use. The VVK100-SYS includes […]

View All
Latest News

New Ventilator Validation Kit for Rapid Development & Field Testing

New Ventilator Validation System Allows Device Manufacturers to Test Ventilator Pressure and Volume System supports rapid development and testing of hardware for COVID-19 treatment Goleta, California – March 24, 2020 BIOPAC Systems, Inc. announced a new Ventilator Validation System for engineering and device manufacturers to use when designing and testing new and existing ventilators for […]

New Citations | VR Hazard Training for Astronauts

Space Flight Simulations Prevent Disasters Under psychological and physical stress, astronauts can put their  mission and crew in danger. Looking into this issue, researchers created a potentially catastrophic spaceflight simulation using a virtual reality environment and recorded the heart rate of participants. Psychophysiological responses to the potentially disastrous flight simulation were recorded using a BIOPAC MP […]

Read All
Request a Demonstration
Request a Demonstration