NICO Smart Amplifier

Request More Info
View Cart “Leads for D-Series EBI/NICO” has been added to your cart.
Smart Amp Thermistor
Part #: NICO100D

The NICO Smart Amplifier is specifically designed to measure thoracic impedance for performing noninvasive cardiac output measurements. The amplifier terminates in two connectors for impedance (Z) and its derivative (dZ), and has a 3 m cable that connects directly to an AMI100D Amplifier Input Module. Use with EL526 strip electrodes and CBL246 adapter or with EL500 series disposable electrodes and LEAD131 for a four-spot electrode configuration or LEAD132 for an eight-spot electrode configuration; contact BIOPAC for use with ICG tape.

BIOPAC’s new Smart Amplifiers are designed for great data. Smart Amplifiers improve performance by amplifying the physiological signal close to the subject, which allows a high-level voltage connection to the data acquisition system and reduces noise artifact.

AcqKnowledge Smart Amp setup includes guides and prompts to prevent errors. Plus, channels are automatically set to be plotted and included in input values display, with the initial visual range set to the min/max input range for that Smart Amplifier signal type, in appropriate units.

The Smart Amplifier may be attached to the subject either using the included self-adhering clip or optional self-adhering straps around the subject.

See More...

Impedance Amp
View Spec PDF

Are You Looking for These?

Part #: NICO100D
Categories: Smart Amplifiers - Research, Amplifiers - Research
Subcategories: Transducer Amplifiers - Research

Alternatives
For the same Platform

Equivalents
With a different Platform

Details

Compatibility


Reduced wiring in Smart Amp setups reduces ambient and common mode noise, increases comfort, and improves the group dynamic!

Smart Amplifiers connect to an MP160 Research System via an Amplifier Interface Module (AMI100D); Smart Amps are not compatible with MP150, MP100, HLT100C, or MP36R devices. For output, add CBL237 with OUTISO or similar. AcqKnowledge Smart Amp setup includes guides and prompts to prevent errors. Plus, channels are automatically set to be plotted and included in input values display, with the initial visual range set to the min/max input range for the Smart Amplifier signal type, in appropriate units. AcqKnowledge 5.0.4 and above support Smart Amp functionality.

AcqKnowledge Smart Amp setupAuto-detect signal type & offer derived measures

Green: configured & detected

Red: configured but not found

White: available

Dashed: unavailable—in use by another analog input

For quick access to Smart Amp options, click the CH# box.

 

 

The Smart Amplifier ships with the following accessories:

  • Protective zippered case with accessory pockets
  • Clip for attaching Smart Amplifier to clothing or other materials on the subject
  • One bag of silicone cable ID tags which may be written specific signal type or identifier on and attached to both ends of the cable for easy identification
  • One silicone cable wrap to optionally allow for unused lengths of cable to be wrapped around to shorten overall cable length
  • One cable management clip that may be optionally attached to the cable to route it around the subject

IMPEDANCE CARDIOGRAPHY (ICG) SETUP CONFIGURATIONS

Important: Do no use two NICO100D Smart Amplifiers on the same subject!

setups for absolute and relative Cardiac Output measures

See also: Methodological Guidelines for Impedance Cardiography , PSYCHOPHYSIOLOGY, Vol. 27, No. 1

Videos

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

Automated ECG Analysis- Lead II

BIOPAC Research Solutions | ECG

Classify Heartbeats

EL-CHECK Electrode Impedance Checker

Marking and Interpolating Segments

Support

Application Notes

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
Impedance electrodes with leads

Bioimpedance Strip Electrode with Leads

Pack of four strip electrodes with TP leads attached, intended for bioimpedance applications. Each electrode is 16.5 cm x 1.3 cm (6.5″ x 0.5″) with four 15 cm lead cables that terminate in 1.5 mm Touch Proof sockets. The electrode  is foam backed and uses hydrogel to adhere the electrode to the participant and provide […]

View All
Latest News

New Citations | BIOPAC in Exercise Physiology

Exercise physiology is the study of the body’s response to physical activity. Research in exercise physiology allows for insights in health and for a better understanding of the functions of the body at work. Here are some recent studies in exercise physiology that utilized BIOPAC tools for their research… Effect of exercise on electrocardiographic parameters […]

Electrocardiography Guide Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration