BIOPAC® Systems, Inc. Logo

Mobita ConfiCaps

Mobita®: Wearable Biopotentials

Record up to 32 channels of wireless data

Request More Info
Mobita ConfiCap for 32-CH wireless EEG
Part #: MB-32EEG-CAP-A, MB-12+20-CAP, MB-20EEG-CAP-B

ConfiCaps™ connect to an existing Mobita® base unit for wireless, wearable biopotential recording—options include 32-channel EEG, 10/20 EEG + 13 TP adapters, and 12 surface electrodes + 20 TP adapters. Assemblies include a trigger connector for synchronization with other devices. Snap the assembly to a Mobita base unit and complete subject connections to record up to 32 channels of data for either in laboratory telemetry or remote data logging applications.

  • With water electrodes, subject ground* (GND) requires adhesive snap electrode, such as EL503 or EL504, not included

Mobita can record many different signal types.

Quickly change the electrode configuration or signal type by swapping out the ConfiCap to change inputs for specific applications (i.e., 32-ch EEG, EMG, or combinations of ECG/EMG/EEG, etc.), customize your own design, or create research protocol driven configurations. Simply disconnect one header and snap on a new configuration for a completely different application. Each channel is unipolar (single-ended) and AcqKnowledge is easily configured to create unique montages and combinations of signals. Record a 12-lead ECG while recording EEG and EMG data all with the same device.

With AcqKnowledge and Mobita, the system is quickly configured to do the work of multiple systems without the added cost of multiple amplifiers.

See More...

Mobita 32-channel EEG ConfiCap
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Mobita Wearable Biopotentials: 32CH EEG, ECG, EMG, EOG, EGG - Research
Subcategories: ConfiCap Interface - Research

Details

Compatibility


Mobita ConfiCap connectionThe Mobita supports TTL trigger inputs from third-party hardware; contact BIOPAC for isolated Trigger interface.

EEG Water electrodes

Completely new type of EEG sensor that measures using just plain water!

Developed during the European BRAIN project, after a period of profound research, the 32-channel EEG ConfiCap is used with an H20 headcap and water electrodes, which eliminate the need for gel. Water electrodes should remain moist for up to eight hours of operation; the rubber ring in the electrode cap must make good contact with the subject to seal off the soaked insert and prevent it from drying out. EEG water electrodes

Ground

The ConfiCap’s green connector most often serves as a subject ground (GND). Simply apply an adhesive snap electrode (such as the BIOPAC EL500 series) to the subject’s forehead and attach the green connector. The Mobita has a “lead off” detection for the ground lead. If the ground lead is disconnected or if there is a poor ground connection, all input signals from the unit will flatline and the ground connection and electrode should be checked.

Analyze with AcqKnowledge

EEG App Mobita

EMG App Mobita Facial EMG

EMG App Mobita Leg

ECG App Mobita 12-Lead

Videos

Integrating BIOPAC Research Systems | Data Acquisition & Analysis

Mobita Network Configuration

Automated ECG Analysis- Lead II

EEG Frequency Analysis | AcqKnowledge Demonstration

EEG - Automated Filtering

EMG - Derive Integrated EMG

BIOPAC Research Solutions | EEG

Support

Downloads/Resources

Knowledge Base

Manual

Recommended Items

Spotlight On
free BIOPAC webinar

Fundamentals of Physiological Data Recording

Basic principles of physiological data collection covers fundamentals of data collection and equipment configuration equipment to help you refine experiment protocols and avoid costly missteps. Frazer Findlay, CEO of BIOPAC, discusses common mistakes with physiology recording and shares his secrets for collecting great data. Topics include: How to prep a subject and where to place electrodes; Which type of electrodes work for different body signals; Analog to Digital Conversion; Sample rates (correct vs. incorrect); Filtering; and Scaling and calibration.
Watch On Demand Now!

Register Now
Latest News

New Citations | The secret is always exercise!

Recent Exercise Physiology studies feature BIOPAC’s MP Research series of Data Collection recorders and AcqKnowledge software. These studies promote healthy living and observe muscle response to normal physiological motions during exercise! Trampoline Workouts for Seniors? As we get older, our joints ache and muscles stiffen—but scientists are finding new ways to not only help us […]

Electrocardiography Guide Now Available

BIOPAC’s just released Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines […]

Read All
Request a Demonstration
Request a Demonstration