Gas Analysis Systems – CO2 and O2

The Gold Standard for Better Science and Greater Discovery

Real-time VO2 and RER

CO2 and O2 Gas Analysis System for MP, 5 L
Part #: GASSYS2-EA, GASSYS2-EB

Obtain real-time Oxygen Consumption (VO2) and Respiratory Exchange Ratio (RER) measurements using a BIOPAC data acquisition system with the Gas Analysis module and some air flow accessories.

Measure expired O2 and CO2 concentrations.

  • When the subject inspires, air will be drawn into the GASSYS2 through the SS11LA/B air flow transducer, which is placed on the inspiration side to eliminate any effects associated with expired air humidity.
  • When the subject expires, air will be directed to the GASSYS2 module, which is designed to work with saturated expired air.

Login for pricing

Clear selection
   Request More Info
BIOPAC data acquisition
View Spec PDF

Are You Looking for These?

Part #: N/A
Categories: Gas Analysis - Education
Subcategories: Gas Analysis Modules - Education

Details

Compatibility


The non-rebreathing “T” valve directs only expired air to the GASSYS2. Because only expired air is directed to the module, the system acts to average respiratory outflows. This averaging effect causes the CO2 and O2 concentrations to vary in accordance to the mean values resident in a few expired breaths.

Options

Each chamber assembly includes the chamber casing and rod. The chambers work exactly the same way and are interchangeable on the module base. Use the 1.7 L chamber for small children/medium sized animals.

Ships with AFT7 smooth bore tubing, AFT11E flexible coupler, and AFT22 non-rebreathing T-valve. See AFT Series for other air flow and gas analysis accessories.

The non-rebreathing “T” valve directs only expired air to the GASSYS2. Because only expired air is directed to the module, the system acts to average respiratory outflows. This averaging effect causes the CO2 and O2 concentrations to vary in accordance to the mean values resident in a few expired breaths.

Validation

Citation using the BIOPAC indirect calorimeter for determining resting energy expenditure in healthy free-living older people: K. Khalaj-Hedayati et al. / Nutrition Research 29 (2009) 531–541

Chamber Options
Two chamber sizes are available for the GASSYS2. Each chamber assembly includes the chamber casing and rod. The chambers work exactly the same way and are interchangeable on the module base. Use the smaller chamber size for small children/medium sized animals.

  • 5-liter chamber: included in the GASSYS2-RA; Order the chamber only as RX-GASA
  • 1-liter chamber: included in the GASSYS2-RB ; Order the chamber only as RX-GASB

Support

Applications

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
small animal tail noninvasive blood pressure monitor

Sm. Animal Tail BP Monitor System

The NIBP250 small animal tail noninvasive blood pressure monitor is a stand-alone device to measure the blood pressure of small animals and has a touch screen LCD user interface to control the system and display the data. The monitor does not require a data acquisition system or computer to analyze the data, but can interface […]

View All
Latest News

New Citations—VR Muscle Training, Hypertension, & Stem Cell Smile Reconstruction

Virtual Reality Muscle Training in Stroke Patients: Muscle weakening of the lower extremities has a significant correlation with loss of balance and walking ability in stroke patients. Researchers at Sehan University studied the effect of a virtual reality-based eccentric training program on lower extremity muscle activation and balance for rehabilitation of stroke patients. BIOPAC’s EMG100C surface […]

New Citations—ECG Personal Identification, Cognitive Decline and Exercise, & Mechanical Impulses

Personal Identification: Researchers from Yonsei University recently performed a study testing the viability of using ECG signals for individual identification, much like a password or key. Their study investigated experiments that recorded ECG after exercise and estimated the recognition potential of these signals. ECG was measured from subjects using the BIOPAC MP150 data acquisition system […]

Read All
Request a Demonstration
Request a Demonstration