Compatibility
Reduced wiring in Smart Amp setups reduces ambient and common mode noise, increases comfort, and improves the group dynamic!
AcqKnowledge Smart Amp setup includes guides and prompts to prevent errors. Plus, channels are automatically set to be plotted and included in input values display, with the initial visual range set to the min/max input range for that Smart Amplifier signal type, in appropriate units.
The Smart Amplifier may be attached to the subject either using the included Velcro backed clip or optional self-adhering straps around the subject. The amplifier terminates with a 3 m long cable and connects to the AMI100D Amplifier Input Module.
Smart Amplifiers connect to an MP160 Research System via an Amplifier Interface Module (AMI100D); Smart Amps are not compatible with MP150, MP100, HLT100C, or MP36R devices. For output, add CBL237 with OUTISO or similar. AcqKnowledge Smart Amp setup includes guides and prompts to prevent errors. Plus, channels are automatically set to be plotted and included in input values display, with the initial visual range set to the min/max input range for the Smart Amplifier signal type, in appropriate units. AcqKnowledge 5.0.4 and above support Smart Amp functionality.
Auto-detect signal type & offer derived measures
Green: configured & detected
Red: configured but not found
White: unused/available
Dashed: in use/not available
For quick access to Smart Amp options, click the CH# box.
Use with:
Mini-pinch leads, two-lead or three-lead in 15 cm, 30 cm, or 45 cm
BN-EL15-LEAD2BN-EL30-LEAD2 BN-EL45-LEAD2
BN-EL15-LEAD3 BN-EL30-LEAD3 BN-EL45-LEAD3
Touchproof adapters, 15 cm, sockets accept TP leads
BN-ADAPT-TP2 (+,-) BN-ADAPT-TP3 (+. -, GND)
Electrodes: vinyl or cloth, pre-gelled or dry
EL500 series disposable electrodes
Featured Research Articles
- Phase-locking of resting-state brain networks with the gastric basal electrical rhythm. Choe AS, Tang B, Smith KR, Honari H, Lindquist MA, Caffo BS, et al. (2021). PLoS ONE 16(1): e0244756. https://doi.org/10.1371/journal.pone.0244756
- Electrogastrography: Methodology, Validation and Applications, Jieyun Yin, Jiande D Z Chen. J Neurogastroenterol Motil. 2013 January; 19(1): 5–17. Published online 2013 January 8. doi: 10.5056/jnm.2013.19.1.5. PMCID: PMC3548127
- Gut Feelings, Intuition, and Emotions: An Exploratory Study, Dean I. Raqdin, Ph.D. and Marilyn J. Schultz, Ph.D., The Journal of Alternative and Complementary Medicine, Volume 11, Number 1, 2005, pp. 85–91
Stay Connected