BIOPAC® Systems, Inc. Logo

EDA Analysis Software Module

The Premier Data Acquisition & Analysis Program: AcqKnowledge®

Software module for advanced analysis

Request More Info
View Cart “BioNomadix Wireless PPG and EDA Amplifier” has been added to your cart.
EDA GSR Recording and Analysis System
Part #: ACKEDA

Electrodermal Activity Analysis Module 
Use the Power of MP Research Systems with AcqKnowledge Software
for a Complete EDA/GSR Recording and Analysis Solution!

AcqKnowledge software includes the following automated EDA/GSR routines, along with dozens of other automated analysis routines and transformation tools:

  • Locate Skin Conductance Responses (SCRs)
  • Event Related EDA/GSR Analysis
  • Construct Phasic EDA/GSR Waveform from Tonic Waveform

Set up and recording is streamlined via intuitive hardware and software controls.

See More...

AcqKnowledge
View Spec PDF

Are You Looking for These?

Part #: ACKEDA
Categories: Software - Research
Subcategories: AcqKnowledge & Upgrades - Research

Details

Compatibility


AcqKnowledge software utilizes guided channel setting allowing the user to easily input recording channel data. Once parameters are established, recording settings can be saved as a graph template for future use. This allows for instant start up for subsequent recording sessions.

During recording, see real-time live raw EDA/GSR data as well as real-time filtering or calculation channels including High-pass filtered/AC Coupled EDA/GSR. Easily insert markers via the computer keyboard for different stimuli presentation or experimental conditions throughout recording. Markers can also be inserted by stimulus presentation programs such as E-Prime or SuperLab using the isolated digital interface (STP100C) or by digital handswitches.

EDA Data in AcqKnowledge EDA Data in AcqKnowledge

EDA/GSR and other physiological data can also be synchronized to video recording via BIOPAC Camera Systems. With Camera Systems EDA/GSR data and Video Data are time linked in AcqKnowledge. Simply scroll through either the video or physiological data to be taken to the corresponding data point in the other file.

AcqKnowledge video sync

Physiology and Linked Video Data

After recording, take advantage of fully automated EDA/GSR analysis routines in AcqKnowledge. Use guided video tutorials to get the most out of all available analysis tools.

EDA/GSR Automated Analysis Package Overview

The Electrodermal Activity analysis routines are separated into three menu options that transform the tonic (raw) EDA/GSR signal to create a phasic (AC coupled) waveform, locate and score skin conductance responses, or perform a detailed event-related EDA analysis by combining marker information from the Stimulus-Response: Digital Input to Stim Events routine to the event-related EDA/GSR Analysis routine. The Event-related routine will automatically derive the phasic waveform and locate SCRs.

Locate Skin Conductance Responses (SCRs)

Identify skin conductance responses and score them on the waveform. Use this analysis to analyze spontaneously occurring skin conductance responses.

EDA with SCRs located

Event Related EDA/GSR Analysis

This routine locates skin conductance responses (SCRs) on the EDA/GSR waveform that are associated with stimulus delivery events. Markers are inserted on the graph to allow for further data analysis around the SCR positions. The Analysis routine then outputs a summary table of specific vs non-specific SCRs and corresponding measurements for each response.

Additional options for multiple stimulus event types and unmatched events are available, including:

  • Labels and additional measures in the specific stimulus and SCR analysis table
  • Text and Excel tables may be optionally sorted either by time or grouped by stimulus label
  • Table listing stimulus events that were not paired with an SCR
  • The SRR/NS.SSR Rate analysis, which counts frequencies of SCRs in specific time periods, can be driven by time periods defined using pairs of events or a selection in the graph
  • Table listing amplitude/frequency percentage statistics for all matched and unmatched stimuli events (e.g. total stimulus count, percentage of stimuli that were pared with an SCR, etc.)
  • Specific-SCR events may be defined on the tonic EDA waveform at the positions of specific SCRs with labels matching the stimulus to which they correspond. (This allows for further peak-detector based runs to perform additional data reduction.)

See the Event Related EDA/GSR Analysis in action:

Additional Tools for Recording EDA/GSR in the MRI

Record EDA/GSR data in the MRI by adding on specialized MRI Smart Amplifiers. The EDA100C-MRI amplifier and cable/filter set allow for cleaner data recordings in the MRI environment. After recording, take advantage of automated MRI data processing tools in AcqKnowledge.

EDA Data in MRI

Get Started!

Record up to 16 channels of high-fidelity EDA/GSR and other physiological data either wirelessly with BioNomadix or via standard wired amplifiers. Contact BIOPAC today to customize a complete package with amplifiers, leads, electrodes, and/or transducers for your application.

 

EDA “Electrodermal Activity” is also known as GSR “Galvanic Skin Response.” Use BIOPAC Electrodermal Activety (EDA) hardware to record Galvanic Skin Response (GSR) Data.

Videos

Support

Downloads/Resources

Knowledge Base

Recommended Items

Spotlight On
MP160 with AcqKnowledge and Basic Scripting

MP160 Data Acquisition Systems

MP160 data acquisition and analysis systems with AcqKnowledge software provide a flexible tool for life science research. MP160 data acquisition workstations include all hardware, software, cables, and guides you need to get started. MP160 Data Acquisition Hardware—Ethernet-ready data acquisition and analysis unit can record multiple channels with differing sample rates; record at speeds up to 400 kHz (aggregate). […]

View All
Latest News

New Citations | Physiological Measures to Understand Stress

BIOPAC provides software and hardware that allows research teams to study physiological measures related to stress. Here are a few notable studies using BIOPAC equipment for ECG, EDA, and EEG/ERP. Moms Moderating Stress Can relaxation techniques help lower stress on both mother and fetus? Using an MP36R Data Acquisition system to record ECG and EDA, this study […]

Electrocardiography Guide Now Available

BIOPAC’s comprehensive Introductory ECG Guide addresses fundamental to advanced concerns to optimize electrocardiography data recording and analysis. Topics include: ECG Complex; Electrical and Mechanical Sequence of a Heartbeat; Systole and Diastole; Configurations for Lead I, Lead II, Lead III, 6-lead ECG, 12-lead ECG, precordial leads; Ventricular Late Potentials (VLPs); ECG Measurement Tools; Automated Analysis Routines for extracting, […]

Read All
Request a Demonstration
Request a Demonstration